/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.17.5-051705-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi/HGST Travelstar Z5K500
Device Model: HGST HTS545050A7E680
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: GG2OAH10
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jul 18 06:25:13 2022 -04
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 45) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 113) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 077 062 - 0
2 Throughput_Performance P-S--K 100 100 040 - 0
3 Spin_Up_Time PO---K 253 100 033 - 1
4 Start_Stop_Count -O--CK 098 098 000 - 3430
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 100 100 040 - 0
9 Power_On_Hours -O--CK 090 090 000 - 4592
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 3427
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 001 000 - 154670370479852
188 Command_Timeout -O--CK 100 096 000 - 131091
190 Airflow_Temperature_Cel -O---K 067 051 045 - 33 (Min/Max 33/34)
191 G-Sense_Error_Rate -O--CK 060 060 000 - 10464
192 Power-Off_Retract_Count -O--CK 099 099 000 - 15991028
193 Load_Cycle_Count -O--CK 095 095 000 - 54669
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
223 Load_Retry_Count -O-R-K 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 24354 (device log contains only the most recent 4 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 24354 [1] occurred at disk power-on lifetime: 3828 hours (159 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 88 00 00 1d fb 26 98 0d 00
Error: UNC at LBA = 0x1dfb2698 = 502998680
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:20.845 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:20.845 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:17.467 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:17.467 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:14.090 READ FPDMA QUEUED
Error 24353 [0] occurred at disk power-on lifetime: 3828 hours (159 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 88 00 00 1d fb 26 98 0d 00
Error: UNC at LBA = 0x1dfb2698 = 502998680
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:17.467 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:17.467 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:14.090 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:14.089 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:10.712 READ FPDMA QUEUED
Error 24352 [3] occurred at disk power-on lifetime: 3828 hours (159 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 88 00 00 1d fb 26 98 0d 00
Error: UNC at LBA = 0x1dfb2698 = 502998680
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:14.090 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:14.089 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:10.712 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:10.711 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:07.334 READ FPDMA QUEUED
Error 24351 [2] occurred at disk power-on lifetime: 3828 hours (159 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 88 00 00 1d fb 26 98 0d 00
Error: UNC at LBA = 0x1dfb2698 = 502998680
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:10.712 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:10.711 READ LOG EXT
60 00 a0 00 08 00 00 1d fb 26 80 40 00 06:41:07.334 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 00 00 06:41:07.333 READ LOG EXT
60 00 a0 00 78 00 00 1d fb 26 80 40 00 06:41:03.945 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 4547 -
# 2 Short offline Completed without error 00% 2 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 33/34 Celsius
Lifetime Min/Max Temperature: 7/49 Celsius
Specified Max Operating Temperature: 32 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (1)
Index Estimated Time Temperature Celsius
2 2022-07-18 04:18 33 **************
... ..( 12 skipped). .. **************
15 2022-07-18 04:31 33 **************
16 2022-07-18 04:32 ? -
17 2022-07-18 04:33 34 ***************
... ..( 10 skipped). .. ***************
28 2022-07-18 04:44 34 ***************
29 2022-07-18 04:45 33 **************
... ..( 3 skipped). .. **************
33 2022-07-18 04:49 33 **************
34 2022-07-18 04:50 34 ***************
35 2022-07-18 04:51 33 **************
... ..( 25 skipped). .. **************
61 2022-07-18 05:17 33 **************
62 2022-07-18 05:18 34 ***************
... ..( 21 skipped). .. ***************
84 2022-07-18 05:40 34 ***************
85 2022-07-18 05:41 33 **************
... ..( 8 skipped). .. **************
94 2022-07-18 05:50 33 **************
95 2022-07-18 05:51 ? -
96 2022-07-18 05:52 33 **************
97 2022-07-18 05:53 34 ***************
98 2022-07-18 05:54 33 **************
99 2022-07-18 05:55 34 ***************
... ..( 2 skipped). .. ***************
102 2022-07-18 05:58 34 ***************
103 2022-07-18 05:59 33 **************
104 2022-07-18 06:00 34 ***************
105 2022-07-18 06:01 34 ***************
106 2022-07-18 06:02 34 ***************
107 2022-07-18 06:03 33 **************
... ..( 10 skipped). .. **************
118 2022-07-18 06:14 33 **************
119 2022-07-18 06:15 34 ***************
120 2022-07-18 06:16 33 **************
121 2022-07-18 06:17 34 ***************
... ..( 5 skipped). .. ***************
127 2022-07-18 06:23 34 ***************
0 2022-07-18 06:24 33 **************
1 2022-07-18 06:25 33 **************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS