Probe #0dcda20e7c of ASRock B450 Pro4 R2.0 Desktop Computer
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-desktop-1omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Lexar SSD NM620 1TB
Serial Number: --
Firmware Version: 12544
PCI Vendor/Subsystem ID: 0x1d97
IEEE OUI Identifier: 0xcaf25b
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: caf25b ...
Local Time is: Sat Jan 25 09:18:12 2025 CET
Firmware Updates (0x1a): 5 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg
Maximum Data Transfer Size: 128 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.50W - - 0 0 0 0 0 0
1 + 5.80W - - 1 1 1 1 0 0
2 + 3.60W - - 2 2 2 2 0 0
3 - 0.7460W - - 3 3 3 3 5000 10000
4 - 0.7260W - - 4 4 4 4 8000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 4%
Data Units Read: 17,654,770 [9.03 TB]
Data Units Written: 53,217,533 [27.2 TB]
Host Read Commands: 201,081,645
Host Write Commands: 330,534,579
Controller Busy Time: 645
Power Cycles: 920
Power On Hours: 1,949
Unsafe Shutdowns: 324
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 36 Celsius
Temperature Sensor 2: 40 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
No Errors Logged
Read Self-test Log failed: Invalid Field in Command (0x002)