/dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-4.15.0-desktop-122.124.1rosa-x86_64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P120
Device Model: SAMSUNG SP2504C
Serial Number: --
Firmware Version: VT100-41
User Capacity: 250,058,268,160 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
Local Time is: Tue Mar 30 13:48:07 2021 +05
==> WARNING: May need -F samsung3 enabled; see manual for details.
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4835) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 80) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 1
3 Spin_Up_Time POS--- 100 100 025 - 5888
4 Start_Stop_Count -O--CK 075 075 000 - 25571
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 35232
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
12 Power_Cycle_Count -O--CK 087 087 000 - 13718
187 Reported_Uncorrect -O--CK 001 001 000 - 1443738
190 Airflow_Temperature_Cel -O---K 136 082 000 - 34
194 Temperature_Celsius -O---K 136 082 000 - 34
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2000025
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 100 000 - 0
198 Offline_Uncorrectable ----CK 253 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 100 000 - 1
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Invalid Error Log index = 0x0000, trying reserved byte (0x06) instead
Device Error Count: 1958 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1958 [5] occurred at disk power-on lifetime: 35183 hours (1465 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 06 aa b4 00 e0 00
Error: UNC 8 sectors at LBA = 0x06aab400 = 111850496
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 06 aa b4 00 e0 00 00:00:42.750 READ DMA EXT
Error 1957 [4] occurred at disk power-on lifetime: 35183 hours (1465 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 06 aa b4 00 e0 00
Error: UNC 8 sectors at LBA = 0x06aab400 = 111850496
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 06 aa b4 00 e0 00 00:00:41.000 READ DMA EXT
25 00 00 00 08 00 00 06 aa b4 08 e0 00 00:00:39.313 READ DMA EXT
25 00 00 00 08 00 00 06 aa b3 f8 e0 00 00:00:39.250 READ DMA EXT
25 00 00 00 08 00 00 06 aa b3 f0 e0 00 00:00:39.250 READ DMA EXT
25 00 00 00 08 00 00 06 ac b3 e8 e0 00 00:00:39.250 READ DMA EXT
Error 1956 [3] occurred at disk power-on lifetime: 35183 hours (1465 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 06 aa b3 f0 e0 00
Error: UNC 32 sectors at LBA = 0x06aab3f0 = 111850480
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 06 aa b3 f0 e0 00 00:00:39.188 READ DMA EXT
25 00 00 00 80 00 00 0b 86 98 e0 e0 00 00:00:37.438 READ DMA EXT
25 00 00 00 80 00 00 0b 86 98 60 e0 00 00:00:37.438 READ DMA EXT
25 00 00 00 80 00 00 0b 86 97 e0 e0 00 00:00:37.375 READ DMA EXT
25 00 00 00 80 00 00 0b 86 97 60 e0 00 00:00:37.375 READ DMA EXT
Error 1955 [2] occurred at disk power-on lifetime: 34184 hours (1424 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 63 ed f0 e0 00
Error: UNC 8 sectors at LBA = 0x0063edf0 = 6548976
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 00 63 ed f0 e0 00 02:26:47.375 READ DMA EXT
25 00 00 00 40 00 00 08 e1 75 e0 e0 00 02:26:45.688 READ DMA EXT
25 00 00 00 08 00 00 00 63 ed e8 e0 00 02:26:45.688 READ DMA EXT
25 00 00 00 08 00 00 00 0b b3 d8 e0 00 02:26:45.688 READ DMA EXT
25 00 00 00 40 00 00 08 e1 75 a0 e0 00 02:26:45.625 READ DMA EXT
Error 1954 [1] occurred at disk power-on lifetime: 34184 hours (1424 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 00 63 ed e0 e0 00
Error: UNC 32 sectors at LBA = 0x0063ede0 = 6548960
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 63 ed e0 e0 00 02:26:45.500 READ DMA EXT
25 00 00 00 40 00 00 08 e1 75 20 e0 00 02:26:43.813 READ DMA EXT
25 00 00 00 08 00 00 00 0b b3 c8 e0 00 02:26:43.813 READ DMA EXT
25 00 00 00 40 00 00 08 f5 d2 c0 e0 00 02:26:43.813 READ DMA EXT
25 00 00 00 40 00 00 08 e1 74 e0 e0 00 02:26:43.750 READ DMA EXT
Error 1953 [0] occurred at disk power-on lifetime: 34184 hours (1424 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 63 28 68 e0 00
Error: UNC 8 sectors at LBA = 0x00632868 = 6498408
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 00 63 28 68 e0 00 02:20:53.000 READ DMA EXT
25 00 00 00 08 00 00 00 63 28 60 e0 00 02:20:51.313 READ DMA EXT
25 00 00 00 80 00 00 03 e7 aa 20 e0 00 02:20:51.313 READ DMA EXT
Error 1952 [7] occurred at disk power-on lifetime: 34184 hours (1424 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 00 63 28 60 e0 00
Error: UNC 32 sectors at LBA = 0x00632860 = 6498400
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 63 28 60 e0 00 02:20:51.250 READ DMA EXT
25 00 00 00 80 00 00 04 3f ca 88 e0 00 02:20:49.563 READ DMA EXT
25 00 00 00 80 00 00 04 3f ca 08 e0 00 02:20:49.563 READ DMA EXT
35 00 00 00 08 00 00 00 5f 16 f0 e0 00 02:20:49.563 WRITE DMA EXT
25 00 00 00 80 00 00 04 3f c9 88 e0 00 02:20:49.563 READ DMA EXT
Error 1951 [6] occurred at disk power-on lifetime: 34184 hours (1424 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 00 65 24 58 e0 00
Error: UNC 8 sectors at LBA = 0x00652458 = 6628440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 00 65 24 58 e0 00 02:20:16.500 READ DMA EXT
25 00 00 00 08 00 00 00 65 24 50 e0 00 02:20:14.813 READ DMA EXT
25 00 00 00 08 00 00 00 65 24 48 e0 00 02:20:14.813 READ DMA EXT
25 00 00 00 08 00 00 00 65 24 40 e0 00 02:20:14.813 READ DMA EXT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 34531 -
# 2 Extended offline Completed: read failure 90% 29515 236584968
# 3 Extended offline Completed: read failure 90% 29493 236584968
# 4 Extended offline Completed: read failure 50% 28022 236584968
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: --/34 Celsius
Lifetime Min/Max Temperature: --/52 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 10/55 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (124)
Index Estimated Time Temperature Celsius
125 2021-03-30 11:41 39 ********************
126 2021-03-30 11:42 39 ********************
127 2021-03-30 11:43 40 *********************
0 2021-03-30 11:44 40 *********************
1 2021-03-30 11:45 40 *********************
2 2021-03-30 11:46 41 **********************
3 2021-03-30 11:47 41 **********************
4 2021-03-30 11:48 41 **********************
5 2021-03-30 11:49 42 ***********************
... ..( 6 skipped). .. ***********************
12 2021-03-30 11:56 42 ***********************
13 2021-03-30 11:57 44 *************************
14 2021-03-30 11:58 43 ************************
... ..( 49 skipped). .. ************************
64 2021-03-30 12:48 43 ************************
65 2021-03-30 12:49 44 *************************
... ..( 21 skipped). .. *************************
87 2021-03-30 13:11 44 *************************
88 2021-03-30 13:12 43 ************************
89 2021-03-30 13:13 43 ************************
90 2021-03-30 13:14 ? -
91 2021-03-30 13:15 21 **
92 2021-03-30 13:16 22 ***
93 2021-03-30 13:17 23 ****
94 2021-03-30 13:18 24 *****
95 2021-03-30 13:19 25 ******
96 2021-03-30 13:20 25 ******
97 2021-03-30 13:21 26 *******
98 2021-03-30 13:22 26 *******
99 2021-03-30 13:23 27 ********
100 2021-03-30 13:24 27 ********
101 2021-03-30 13:25 28 *********
102 2021-03-30 13:26 28 *********
103 2021-03-30 13:27 29 **********
104 2021-03-30 13:28 29 **********
105 2021-03-30 13:29 30 ***********
... ..( 2 skipped). .. ***********
108 2021-03-30 13:32 30 ***********
109 2021-03-30 13:33 31 ************
110 2021-03-30 13:34 31 ************
111 2021-03-30 13:35 31 ************
112 2021-03-30 13:36 32 *************
... ..( 4 skipped). .. *************
117 2021-03-30 13:41 32 *************
118 2021-03-30 13:42 33 **************
... ..( 4 skipped). .. **************
123 2021-03-30 13:47 33 **************
124 2021-03-30 13:48 34 ***************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x8001 2 0 Vendor specific