Probe #1f3dee2cf2 of Casper EXCALIBUR G770
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.4.8-desktop-2omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: CT500P3SSD8
Serial Number: --
Firmware Version: P9CR30A
PCI Vendor/Subsystem ID: 0xc0a9
IEEE OUI Identifier: 0x00a075
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Jan 2 02:01:49 2025 +03
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.00W 0.0000W - 0 0 0 0 0 0
1 + 3.00W 0.0000W - 0 0 0 0 0 0
2 + 1.50W 0.0000W - 0 0 0 0 0 0
3 - 0.0250W 0.0000W - 3 3 3 3 5000 1900
4 - 0.0030W - - 4 4 4 4 13000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 31 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 24,122,923 [12.3 TB]
Data Units Written: 15,701,263 [8.03 TB]
Host Read Commands: 209,149,137
Host Write Commands: 151,495,502
Controller Busy Time: 1,489
Power Cycles: 501
Power On Hours: 998
Unsafe Shutdowns: 113
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,572
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 31 Celsius
Temperature Sensor 2: 40 Celsius
Temperature Sensor 8: 31 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 1572 0 0x0018 0x4005 0x028 0 0 - Invalid Field in Command
Read Self-test Log failed: Invalid Field in Command (0x2002)