Probe #254ec7747f of ASUSTek ROG STRIX X570-E GAM... Desktop Computer

Log: smartctl

/dev/nvme0n1 smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: CT500P2SSD8 Serial Number: -- Firmware Version: P2CR033 PCI Vendor/Subsystem ID: 0xc0a9 IEEE OUI Identifier: 0x6479a7 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 1 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 6479a7 ... Local Time is: Fri Jun 25 21:17:25 2021 CEST Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 70 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 3.50W - - 0 0 0 0 0 0 1 + 1.90W - - 1 1 1 1 0 0 2 + 1.50W - - 2 2 2 2 0 0 3 - 0.0700W - - 3 3 3 3 5000 1900 4 - 0.0020W - - 4 4 4 4 13000 100000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 39 Celsius Available Spare: 100% Available Spare Threshold: 5% Percentage Used: 0% Data Units Read: 27,823 [14.2 GB] Data Units Written: 115,206 [58.9 GB] Host Read Commands: 360,742 Host Write Commands: 852,675 Controller Busy Time: 17 Power Cycles: 3 Power On Hours: 9 Unsafe Shutdowns: 0 Media and Data Integrity Errors: 0 Error Information Log Entries: 29 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 16 entries) No Errors Logged /dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Toshiba 3.5" DT01ACA... Desktop HDD Device Model: TOSHIBA DT01ACA300 Serial Number: -- LU WWN Device Id: 5 000039 ... Firmware Version: MX6OABB0 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Jun 25 21:17:25 2021 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (22365) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 373) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 139 139 054 - 72 3 Spin_Up_Time POS--- 140 140 024 - 372 (Average 444) 4 Start_Stop_Count -O--C- 100 100 000 - 3753 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 124 124 020 - 33 9 Power_On_Hours -O--C- 099 099 000 - 9577 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 2138 192 Power-Off_Retract_Count -O--CK 097 097 000 - 3755 193 Load_Cycle_Count -O--C- 097 097 000 - 3755 194 Temperature_Celsius -O---- 162 162 000 - 37 (Min/Max 17/48) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 7 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log [OBS-8] 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 7702 - # 2 Short offline Completed without error 00% 7686 - # 3 Short offline Completed without error 00% 7088 - # 4 Short offline Completed without error 00% 7088 - # 5 Short offline Aborted by host 90% 7088 - # 6 Short offline Completed without error 00% 7088 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 36 Celsius Power Cycle Min/Max Temperature: 28/37 Celsius Lifetime Min/Max Temperature: 17/48 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (81) Index Estimated Time Temperature Celsius 82 2021-06-25 19:10 36 ***************** ... ..( 7 skipped). .. ***************** 90 2021-06-25 19:18 36 ***************** 91 2021-06-25 19:19 37 ****************** 92 2021-06-25 19:20 36 ***************** ... ..( 5 skipped). .. ***************** 98 2021-06-25 19:26 36 ***************** 99 2021-06-25 19:27 37 ****************** 100 2021-06-25 19:28 37 ****************** 101 2021-06-25 19:29 36 ***************** ... ..( 3 skipped). .. ***************** 105 2021-06-25 19:33 36 ***************** 106 2021-06-25 19:34 37 ****************** 107 2021-06-25 19:35 37 ****************** 108 2021-06-25 19:36 37 ****************** 109 2021-06-25 19:37 36 ***************** ... ..( 2 skipped). .. ***************** 112 2021-06-25 19:40 36 ***************** 113 2021-06-25 19:41 37 ****************** 114 2021-06-25 19:42 36 ***************** 115 2021-06-25 19:43 37 ****************** ... ..( 19 skipped). .. ****************** 7 2021-06-25 20:03 37 ****************** 8 2021-06-25 20:04 36 ***************** 9 2021-06-25 20:05 36 ***************** 10 2021-06-25 20:06 36 ***************** 11 2021-06-25 20:07 37 ****************** 12 2021-06-25 20:08 37 ****************** 13 2021-06-25 20:09 36 ***************** ... ..( 5 skipped). .. ***************** 19 2021-06-25 20:15 36 ***************** 20 2021-06-25 20:16 37 ****************** 21 2021-06-25 20:17 37 ****************** 22 2021-06-25 20:18 36 ***************** ... ..( 3 skipped). .. ***************** 26 2021-06-25 20:22 36 ***************** 27 2021-06-25 20:23 37 ****************** 28 2021-06-25 20:24 37 ****************** 29 2021-06-25 20:25 37 ****************** 30 2021-06-25 20:26 36 ***************** ... ..( 4 skipped). .. ***************** 35 2021-06-25 20:31 36 ***************** 36 2021-06-25 20:32 37 ****************** 37 2021-06-25 20:33 37 ****************** 38 2021-06-25 20:34 36 ***************** ... ..( 3 skipped). .. ***************** 42 2021-06-25 20:38 36 ***************** 43 2021-06-25 20:39 37 ****************** 44 2021-06-25 20:40 37 ****************** 45 2021-06-25 20:41 37 ****************** 46 2021-06-25 20:42 36 ***************** 47 2021-06-25 20:43 37 ****************** 48 2021-06-25 20:44 36 ***************** 49 2021-06-25 20:45 36 ***************** 50 2021-06-25 20:46 37 ****************** ... ..( 3 skipped). .. ****************** 54 2021-06-25 20:50 37 ****************** 55 2021-06-25 20:51 36 ***************** ... ..( 3 skipped). .. ***************** 59 2021-06-25 20:55 36 ***************** 60 2021-06-25 20:56 37 ****************** 61 2021-06-25 20:57 37 ****************** 62 2021-06-25 20:58 36 ***************** ... ..( 4 skipped). .. ***************** 67 2021-06-25 21:03 36 ***************** 68 2021-06-25 21:04 37 ****************** 69 2021-06-25 21:05 37 ****************** 70 2021-06-25 21:06 36 ***************** 71 2021-06-25 21:07 36 ***************** 72 2021-06-25 21:08 36 ***************** 73 2021-06-25 21:09 37 ****************** ... ..( 7 skipped). .. ****************** 81 2021-06-25 21:17 37 ****************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 2138 --- Lifetime Power-On Resets 0x01 0x010 4 9577 --- Power-on Hours 0x01 0x018 6 88539369596 --- Logical Sectors Written 0x01 0x020 6 396546121 --- Number of Write Commands 0x01 0x028 6 107863098780 --- Logical Sectors Read 0x01 0x030 6 501711614 --- Number of Read Commands 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 9182 --- Spindle Motor Power-on Hours 0x03 0x010 4 9182 --- Head Flying Hours 0x03 0x018 4 3755 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 1 --- Read Recovery Attempts 0x03 0x030 4 6 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 2 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 37 --- Current Temperature 0x05 0x010 1 34 N-- Average Short Term Temperature 0x05 0x018 1 36 N-- Average Long Term Temperature 0x05 0x020 1 48 --- Highest Temperature 0x05 0x028 1 17 --- Lowest Temperature 0x05 0x030 1 41 N-- Highest Average Short Term Temperature 0x05 0x038 1 25 N-- Lowest Average Short Term Temperature 0x05 0x040 1 39 N-- Highest Average Long Term Temperature 0x05 0x048 1 25 N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 17381 --- Number of Hardware Resets 0x06 0x010 4 14953 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/sdb smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda Green (AF) Device Model: ST2000DL003-9VT166 Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: CC32 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Jun 25 21:17:28 2021 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 0 (vendor specific), recommended: 254 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 623) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 352) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x30b7) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 115 099 006 - 84447576 3 Spin_Up_Time PO---- 093 092 000 - 0 4 Start_Stop_Count -O--CK 097 097 020 - 3322 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 079 060 030 - 96269591 9 Power_On_Hours -O--CK 088 088 000 - 10568 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 098 098 020 - 2636 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 096 000 - 4295032861 189 High_Fly_Writes -O-RCK 097 097 000 - 3 190 Airflow_Temperature_Cel -O---K 061 048 045 - 39 (Min/Max 27/39) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 434 193 Load_Cycle_Count -O--CK 099 099 000 - 3477 194 Temperature_Celsius -O---K 039 052 000 - 39 (0 14 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 019 008 000 - 84447576 197 Current_Pending_Sector -O--C- 100 100 000 - 8 198 Offline_Uncorrectable ----C- 100 100 000 - 8 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 3 240 Head_Flying_Hours ------ 100 253 000 - 10696 (111 156 0) 241 Total_LBAs_Written ------ 100 253 000 - 889617536 242 Total_LBAs_Read ------ 100 253 000 - 2934433473 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 20 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xab GPL VS 1 Device vendor specific log 0xb0 GPL VS 2819 Device vendor specific log 0xbd GPL VS 252 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 10219 - # 2 Short offline Completed without error 00% 8700 - # 3 Conveyance offline Completed without error 00% 8103 - # 4 Short offline Completed without error 00% 8103 - # 5 Short offline Completed without error 00% 8103 - # 6 Short offline Completed without error 00% 8103 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 39 Celsius Power Cycle Min/Max Temperature: 27/39 Celsius Lifetime Min/Max Temperature: 14/52 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 59 minutes Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (119) Index Estimated Time Temperature Celsius 120 2021-06-20 16:07 32 ************* 121 2021-06-20 17:06 32 ************* 122 2021-06-20 18:05 ? - 123 2021-06-20 19:04 27 ******** 124 2021-06-20 20:03 27 ******** 125 2021-06-20 21:02 34 *************** 126 2021-06-20 22:01 ? - 127 2021-06-20 23:00 24 ***** 0 2021-06-20 23:59 24 ***** 1 2021-06-21 00:58 37 ****************** 2 2021-06-21 01:57 37 ****************** 3 2021-06-21 02:56 39 ******************** 4 2021-06-21 03:55 ? - 5 2021-06-21 04:54 23 **** 6 2021-06-21 05:53 23 **** 7 2021-06-21 06:52 38 ******************* 8 2021-06-21 07:51 39 ******************** 9 2021-06-21 08:50 40 ********************* 10 2021-06-21 09:49 ? - 11 2021-06-21 10:48 39 ******************** 12 2021-06-21 11:47 39 ******************** 13 2021-06-21 12:46 ? - 14 2021-06-21 13:45 38 ******************* 15 2021-06-21 14:44 38 ******************* 16 2021-06-21 15:43 ? - 17 2021-06-21 16:42 38 ******************* 18 2021-06-21 17:41 38 ******************* 19 2021-06-21 18:40 ? - 20 2021-06-21 19:39 39 ******************** 21 2021-06-21 20:38 39 ******************** 22 2021-06-21 21:37 ? - 23 2021-06-21 22:36 21 ** 24 2021-06-21 23:35 21 ** 25 2021-06-22 00:34 ? - 26 2021-06-22 01:33 25 ****** 27 2021-06-22 02:32 25 ****** 28 2021-06-22 03:31 39 ******************** 29 2021-06-22 04:30 ? - 30 2021-06-22 05:29 34 *************** 31 2021-06-22 06:28 34 *************** 32 2021-06-22 07:27 41 ********************** 33 2021-06-22 08:26 ? - 34 2021-06-22 09:25 25 ****** 35 2021-06-22 10:24 25 ****** 36 2021-06-22 11:23 39 ******************** 37 2021-06-22 12:22 41 ********************** 38 2021-06-22 13:21 ? - 39 2021-06-22 14:20 24 ***** 40 2021-06-22 15:19 24 ***** 41 2021-06-22 16:18 39 ******************** 42 2021-06-22 17:17 41 ********************** 43 2021-06-22 18:16 41 ********************** 44 2021-06-22 19:15 42 *********************** 45 2021-06-22 20:14 41 ********************** 46 2021-06-22 21:13 42 *********************** 47 2021-06-22 22:12 42 *********************** 48 2021-06-22 23:11 42 *********************** 49 2021-06-23 00:10 ? - 50 2021-06-23 01:09 25 ****** 51 2021-06-23 02:08 25 ****** 52 2021-06-23 03:07 40 ********************* 53 2021-06-23 04:06 42 *********************** 54 2021-06-23 05:05 41 ********************** 55 2021-06-23 06:04 41 ********************** 56 2021-06-23 07:03 ? - 57 2021-06-23 08:02 23 **** 58 2021-06-23 09:01 23 **** 59 2021-06-23 10:00 38 ******************* 60 2021-06-23 10:59 40 ********************* 61 2021-06-23 11:58 41 ********************** 62 2021-06-23 12:57 41 ********************** 63 2021-06-23 13:56 41 ********************** 64 2021-06-23 14:55 40 ********************* ... ..( 2 skipped). .. ********************* 67 2021-06-23 17:52 40 ********************* 68 2021-06-23 18:51 41 ********************** 69 2021-06-23 19:50 41 ********************** 70 2021-06-23 20:49 41 ********************** 71 2021-06-23 21:48 39 ******************** 72 2021-06-23 22:47 40 ********************* 73 2021-06-23 23:46 ? - 74 2021-06-24 00:45 24 ***** 75 2021-06-24 01:44 24 ***** 76 2021-06-24 02:43 39 ******************** 77 2021-06-24 03:42 40 ********************* 78 2021-06-24 04:41 38 ******************* 79 2021-06-24 05:40 ? - 80 2021-06-24 06:39 20 * 81 2021-06-24 07:38 20 * 82 2021-06-24 08:37 ? - 83 2021-06-24 09:36 22 *** 84 2021-06-24 10:35 22 *** 85 2021-06-24 11:34 36 ***************** 86 2021-06-24 12:33 38 ******************* 87 2021-06-24 13:32 ? - 88 2021-06-24 14:31 27 ******** 89 2021-06-24 15:30 27 ******** 90 2021-06-24 16:29 39 ******************** 91 2021-06-24 17:28 39 ******************** 92 2021-06-24 18:27 39 ******************** 93 2021-06-24 19:26 ? - 94 2021-06-24 20:25 23 **** 95 2021-06-24 21:24 23 **** 96 2021-06-24 22:23 35 **************** 97 2021-06-24 23:22 37 ****************** 98 2021-06-25 00:21 37 ****************** 99 2021-06-25 01:20 38 ******************* 100 2021-06-25 02:19 ? - 101 2021-06-25 03:18 22 *** 102 2021-06-25 04:17 22 *** 103 2021-06-25 05:16 ? - 104 2021-06-25 06:15 23 **** 105 2021-06-25 07:14 23 **** 106 2021-06-25 08:13 37 ****************** 107 2021-06-25 09:12 39 ******************** 108 2021-06-25 10:11 39 ******************** 109 2021-06-25 11:10 39 ******************** 110 2021-06-25 12:09 ? - 111 2021-06-25 13:08 23 **** 112 2021-06-25 14:07 23 **** 113 2021-06-25 15:06 38 ******************* 114 2021-06-25 16:05 ? - 115 2021-06-25 17:04 27 ******** 116 2021-06-25 18:03 27 ******** 117 2021-06-25 19:02 38 ******************* 118 2021-06-25 20:01 39 ******************** 119 2021-06-25 21:00 39 ******************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS /dev/sdc smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SPCC Solid State Disk Serial Number: -- Firmware Version: T0824A0 User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Jun 25 21:17:28 2021 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0 5 Reallocated_Sector_Ct -O--CK 100 100 050 - 0 9 Power_On_Hours -O--CK 100 100 050 - 1594 12 Power_Cycle_Count -O--CK 100 100 050 - 359 160 Unknown_Attribute -O--CK 100 100 050 - 0 161 Unknown_Attribute PO--CK 100 100 050 - 100 163 Unknown_Attribute -O--CK 100 100 050 - 10 164 Unknown_Attribute -O--CK 100 100 050 - 19561 165 Unknown_Attribute -O--CK 100 100 050 - 139 166 Unknown_Attribute -O--CK 100 100 050 - 4 167 Unknown_Attribute -O--CK 100 100 050 - 31 168 Unknown_Attribute -O--CK 100 100 050 - 5050 169 Unknown_Attribute -O--CK 100 100 050 - 100 175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0 176 Erase_Fail_Count_Chip -O--CK 100 100 050 - 0 177 Wear_Leveling_Count -O--CK 100 100 050 - 0 178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 050 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0 192 Power-Off_Retract_Count -O--CK 100 100 050 - 48 194 Temperature_Celsius -O---K 100 100 050 - 40 195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0 196 Reallocated_Event_Count -O--CK 100 100 050 - 0 197 Current_Pending_Sector -O--CK 100 100 050 - 0 198 Offline_Uncorrectable -O--CK 100 100 050 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 1 232 Available_Reservd_Space -O--CK 100 100 050 - 100 241 Total_LBAs_Written ----CK 100 100 050 - 54957 242 Total_LBAs_Read ----CK 100 100 050 - 78535 245 Unknown_Attribute -O--CK 100 100 050 - 53121 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xde GPL VS 8 Device vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 1 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 1 [0] log entry is empty SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 359 --- Lifetime Power-On Resets 0x01 0x010 4 1594 --- Power-on Hours 0x01 0x018 6 3601707808 --- Logical Sectors Written 0x01 0x020 6 0 --- Number of Write Commands 0x01 0x028 6 851923204 --- Logical Sectors Read 0x01 0x030 6 771 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 2 Device-to-host register FISes sent due to a COMRESET /dev/sdd smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Intenso SSD SATA III Serial Number: -- LU WWN Device Id: 5 000000 ... Firmware Version: P0510E User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available, deterministic, zeroed Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Jun 25 21:17:28 2021 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unknown (0xe001) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x71) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate ------ 100 100 000 - 0 5 Reallocated_Sector_Ct ------ 100 100 000 - 0 9 Power_On_Hours ------ 100 100 000 - 2385 12 Power_Cycle_Count ------ 100 100 000 - 1997 160 Unknown_Attribute ------ 100 100 000 - 0 161 Unknown_Attribute ------ 100 100 000 - 111 163 Unknown_Attribute ------ 100 100 000 - 18 164 Unknown_Attribute ------ 100 100 000 - 69511 165 Unknown_Attribute ------ 100 100 000 - 90 166 Unknown_Attribute ------ 100 100 000 - 5 167 Unknown_Attribute ------ 100 100 000 - 36 168 Unknown_Attribute ------ 100 100 000 - 1000 169 Unknown_Attribute ------ 100 100 000 - 97 175 Program_Fail_Count_Chip ------ 100 100 000 - 0 176 Erase_Fail_Count_Chip ------ 100 100 000 - 0 177 Wear_Leveling_Count ------ 100 100 050 - 17 178 Used_Rsvd_Blk_Cnt_Chip ------ 100 100 000 - 0 181 Program_Fail_Cnt_Total ------ 100 100 000 - 0 182 Erase_Fail_Count_Total ------ 100 100 000 - 0 192 Power-Off_Retract_Count ------ 100 100 000 - 85 194 Temperature_Celsius ------ 100 100 000 - 8 195 Hardware_ECC_Recovered ------ 100 100 000 - 0 196 Reallocated_Event_Count ------ 100 100 016 - 0 197 Current_Pending_Sector ------ 100 100 000 - 0 198 Offline_Uncorrectable ------ 100 100 000 - 0 199 UDMA_CRC_Error_Count ------ 100 100 050 - 2 232 Available_Reservd_Space ------ 100 100 000 - 100 241 Total_LBAs_Written ------ 100 100 000 - 382109 242 Total_LBAs_Read ------ 100 100 000 - 444748 245 Unknown_Attribute ------ 100 100 000 - 278044 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 88 Current Device Internal Status Data log 0x25 GPL R/O 64 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Offline Completed without error 00% 2385 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 6 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) Device State: Active (0) Current Temperature: 0 Celsius Power Cycle Min/Max Temperature: 10/10 Celsius Lifetime Min/Max Temperature: 0/30 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/100 Celsius Min/Max Temperature Limit: 0/100 Celsius Temperature History Size (Index): 128 (54) Index Estimated Time Temperature Celsius 55 2021-06-25 19:10 0 - ... ..( 71 skipped). .. - 127 2021-06-25 20:22 0 - 0 2021-06-25 20:23 25 ****** 1 2021-06-25 20:24 28 ********* ... ..( 2 skipped). .. ********* 4 2021-06-25 20:27 28 ********* 5 2021-06-25 20:28 30 *********** 6 2021-06-25 20:29 30 *********** 7 2021-06-25 20:30 27 ******** ... ..( 14 skipped). .. ******** 22 2021-06-25 20:45 27 ******** 23 2021-06-25 20:46 28 ********* ... ..( 2 skipped). .. ********* 26 2021-06-25 20:49 28 ********* 27 2021-06-25 20:50 27 ******** 28 2021-06-25 20:51 27 ******** 29 2021-06-25 20:52 28 ********* 30 2021-06-25 20:53 28 ********* 31 2021-06-25 20:54 10 - ... ..( 21 skipped). .. - 53 2021-06-25 21:16 10 - 54 2021-06-25 21:17 0 - SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 1997 --- Lifetime Power-On Resets 0x01 0x010 4 2385 --- Power-on Hours 0x01 0x018 6 3567071396 --- Logical Sectors Written 0x01 0x020 6 447671069 --- Number of Write Commands 0x01 0x028 6 3377243791 --- Logical Sectors Read 0x01 0x030 6 552769664 --- Number of Read Commands 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 514641 --- Resets Between Cmd Acceptance and Completion 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 29499 --- Number of Hardware Resets 0x06 0x018 4 2 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 3 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/sde smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.42-1-MANJARO] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Green (AF) Device Model: WDC WD30EZRS-00J99B0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 80.00A80 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri Jun 25 21:17:28 2021 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (55080) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 529) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 181 144 021 - 7916 4 Start_Stop_Count -O--CK 097 097 000 - 3273 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 095 095 000 - 4029 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 097 097 000 - 3252 192 Power-Off_Retract_Count -O--CK 199 199 000 - 848 193 Load_Cycle_Count -O--CK 186 186 000 - 43139 194 Temperature_Celsius -O---K 112 092 000 - 40 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 2142 - # 2 Conveyance offline Completed without error 00% 1558 - # 3 Short offline Completed without error 00% 1558 - # 4 Short offline Completed without error 00% 1558 - # 5 Short offline Completed without error 00% 1558 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 27/40 Celsius Lifetime Min/Max Temperature: 21/60 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (170) Index Estimated Time Temperature Celsius 171 2021-06-25 13:20 37 ****************** ... ..( 3 skipped). .. ****************** 175 2021-06-25 13:24 37 ****************** 176 2021-06-25 13:25 38 ******************* ... ..( 9 skipped). .. ******************* 186 2021-06-25 13:35 38 ******************* 187 2021-06-25 13:36 39 ******************** 188 2021-06-25 13:37 38 ******************* 189 2021-06-25 13:38 39 ******************** ... ..( 10 skipped). .. ******************** 200 2021-06-25 13:49 39 ******************** 201 2021-06-25 13:50 40 ********************* 202 2021-06-25 13:51 39 ******************** 203 2021-06-25 13:52 40 ********************* 204 2021-06-25 13:53 40 ********************* 205 2021-06-25 13:54 39 ******************** 206 2021-06-25 13:55 40 ********************* ... ..(113 skipped). .. ********************* 320 2021-06-25 15:49 40 ********************* 321 2021-06-25 15:50 41 ********************** ... ..( 10 skipped). .. ********************** 332 2021-06-25 16:01 41 ********************** 333 2021-06-25 16:02 40 ********************* ... ..( 2 skipped). .. ********************* 336 2021-06-25 16:05 40 ********************* 337 2021-06-25 16:06 39 ******************** 338 2021-06-25 16:07 40 ********************* 339 2021-06-25 16:08 39 ******************** ... ..( 3 skipped). .. ******************** 343 2021-06-25 16:12 39 ******************** 344 2021-06-25 16:13 38 ******************* ... ..( 2 skipped). .. ******************* 347 2021-06-25 16:16 38 ******************* 348 2021-06-25 16:17 39 ******************** ... ..( 6 skipped). .. ******************** 355 2021-06-25 16:24 39 ******************** 356 2021-06-25 16:25 40 ********************* ... ..( 10 skipped). .. ********************* 367 2021-06-25 16:36 40 ********************* 368 2021-06-25 16:37 41 ********************** 369 2021-06-25 16:38 41 ********************** 370 2021-06-25 16:39 41 ********************** 371 2021-06-25 16:40 40 ********************* ... ..( 2 skipped). .. ********************* 374 2021-06-25 16:43 40 ********************* 375 2021-06-25 16:44 41 ********************** ... ..( 45 skipped). .. ********************** 421 2021-06-25 17:30 41 ********************** 422 2021-06-25 17:31 40 ********************* 423 2021-06-25 17:32 40 ********************* 424 2021-06-25 17:33 40 ********************* 425 2021-06-25 17:34 41 ********************** ... ..( 4 skipped). .. ********************** 430 2021-06-25 17:39 41 ********************** 431 2021-06-25 17:40 40 ********************* ... ..( 34 skipped). .. ********************* 466 2021-06-25 18:15 40 ********************* 467 2021-06-25 18:16 39 ******************** 468 2021-06-25 18:17 40 ********************* ... ..( 5 skipped). .. ********************* 474 2021-06-25 18:23 40 ********************* 475 2021-06-25 18:24 39 ******************** 476 2021-06-25 18:25 40 ********************* ... ..( 11 skipped). .. ********************* 10 2021-06-25 18:37 40 ********************* 11 2021-06-25 18:38 39 ******************** 12 2021-06-25 18:39 40 ********************* ... ..( 9 skipped). .. ********************* 22 2021-06-25 18:49 40 ********************* 23 2021-06-25 18:50 39 ******************** 24 2021-06-25 18:51 40 ********************* ... ..( 20 skipped). .. ********************* 45 2021-06-25 19:12 40 ********************* 46 2021-06-25 19:13 ? - 47 2021-06-25 19:14 23 **** 48 2021-06-25 19:15 23 **** 49 2021-06-25 19:16 24 ***** 50 2021-06-25 19:17 25 ****** ... ..( 2 skipped). .. ****** 53 2021-06-25 19:20 25 ****** 54 2021-06-25 19:21 26 ******* 55 2021-06-25 19:22 26 ******* 56 2021-06-25 19:23 26 ******* 57 2021-06-25 19:24 27 ******** 58 2021-06-25 19:25 27 ******** 59 2021-06-25 19:26 28 ********* 60 2021-06-25 19:27 29 ********** ... ..( 2 skipped). .. ********** 63 2021-06-25 19:30 29 ********** 64 2021-06-25 19:31 30 *********** 65 2021-06-25 19:32 30 *********** 66 2021-06-25 19:33 30 *********** 67 2021-06-25 19:34 31 ************ 68 2021-06-25 19:35 31 ************ 69 2021-06-25 19:36 32 ************* ... ..( 3 skipped). .. ************* 73 2021-06-25 19:40 32 ************* 74 2021-06-25 19:41 33 ************** ... ..( 2 skipped). .. ************** 77 2021-06-25 19:44 33 ************** 78 2021-06-25 19:45 34 *************** 79 2021-06-25 19:46 34 *************** 80 2021-06-25 19:47 35 **************** 81 2021-06-25 19:48 34 *************** 82 2021-06-25 19:49 35 **************** ... ..( 7 skipped). .. **************** 90 2021-06-25 19:57 35 **************** 91 2021-06-25 19:58 36 ***************** ... ..( 4 skipped). .. ***************** 96 2021-06-25 20:03 36 ***************** 97 2021-06-25 20:04 37 ****************** ... ..( 4 skipped). .. ****************** 102 2021-06-25 20:09 37 ****************** 103 2021-06-25 20:10 38 ******************* ... ..( 6 skipped). .. ******************* 110 2021-06-25 20:17 38 ******************* 111 2021-06-25 20:18 39 ******************** ... ..( 12 skipped). .. ******************** 124 2021-06-25 20:31 39 ******************** 125 2021-06-25 20:32 40 ********************* 126 2021-06-25 20:33 39 ******************** 127 2021-06-25 20:34 40 ********************* 128 2021-06-25 20:35 39 ******************** 129 2021-06-25 20:36 39 ******************** 130 2021-06-25 20:37 40 ********************* 131 2021-06-25 20:38 ? - 132 2021-06-25 20:39 27 ******** 133 2021-06-25 20:40 27 ******** 134 2021-06-25 20:41 28 ********* 135 2021-06-25 20:42 29 ********** ... ..( 2 skipped). .. ********** 138 2021-06-25 20:45 29 ********** 139 2021-06-25 20:46 30 *********** 140 2021-06-25 20:47 31 ************ 141 2021-06-25 20:48 31 ************ 142 2021-06-25 20:49 31 ************ 143 2021-06-25 20:50 32 ************* ... ..( 3 skipped). .. ************* 147 2021-06-25 20:54 32 ************* 148 2021-06-25 20:55 33 ************** 149 2021-06-25 20:56 33 ************** 150 2021-06-25 20:57 34 *************** ... ..( 3 skipped). .. *************** 154 2021-06-25 21:01 34 *************** 155 2021-06-25 21:02 35 **************** ... ..( 5 skipped). .. **************** 161 2021-06-25 21:08 35 **************** 162 2021-06-25 21:09 36 ***************** ... ..( 5 skipped). .. ***************** 168 2021-06-25 21:15 36 ***************** 169 2021-06-25 21:16 37 ****************** 170 2021-06-25 21:17 37 ****************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x8000 4 11344 Vendor specific


Hardware for Linux and BSD

GitHub