/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: KINGSTON SV300S37A120G
Serial Number: --
LU WWN Device Id: 5 0026b7 ...
Firmware Version: 505ABBF1
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Aug 5 16:16:04 2016 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 096 096 000 - 3728h+09m+10.820s
12 Power_Cycle_Count -O--CK 097 097 000 - 3776
171 Program_Fail_Count -O--CK 000 000 000 - 0
172 Erase_Fail_Count -O--CK 000 000 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 1212
177 Wear_Range_Delta ------ 000 000 000 - 6
181 Program_Fail_Count -O--CK 000 000 000 - 0
182 Erase_Fail_Count -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 040 073 000 - 40 (Min/Max 13/73)
194 Temperature_Celsius -O---K 040 073 000 - 40 (Min/Max 13/73)
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 100 100 010 - 0
233 SandForce_Internal ------ 000 000 000 - 15245
234 SandForce_Internal -O--CK 000 000 000 - 12537
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 12537
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 19969
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x04 SL R/O 1 Device Statistics log
0x09 SL R/W 1 Selective self-test log
0x11 SL R/O 1 SATA Phy Event Counters
0x80-0x9f SL R/W 16 Host vendor specific log
0xb7 SL VS 16 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 40/40 Celsius
Lifetime Min/Max Temperature: 13/73 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 0 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 0 (27)
Temperature History is empty
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE16 Serial ATA
Device Model: WDC WD4000KS-00MNB0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 07.02E07
User Capacity: 400,088,457,216 bytes [400 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Fri Aug 5 16:16:04 2016 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (11880) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 149) minutes.
Conveyance self-test routine
recommended polling time: ( 6) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 253 213 021 - 4008
4 Start_Stop_Count -O--CK 095 095 000 - 5765
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 100 253 051 - 0
9 Power_On_Hours -O--CK 095 095 000 - 3782
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3813
194 Temperature_Celsius -O---K 100 094 000 - 52
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3359 -
# 2 Short offline Completed without error 00% 3354 -
# 3 Short offline Completed without error 00% 3331 -
# 4 Short offline Completed without error 00% 3318 -
# 5 Short offline Completed without error 00% 3255 -
# 6 Short offline Completed without error 00% 3247 -
# 7 Short offline Interrupted (host reset) 90% 3243 -
# 8 Short offline Completed without error 00% 3232 -
# 9 Short offline Completed without error 00% 3220 -
#10 Short offline Completed without error 00% 3215 -
#11 Short offline Completed without error 00% 3207 -
#12 Short offline Completed without error 00% 3197 -
#13 Short offline Completed without error 00% 3192 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 52 Celsius
Power Cycle Max Temperature: 53 Celsius
Lifetime Max Temperature: 58 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (10)
Index Estimated Time Temperature Celsius
11 2016-08-05 14:09 43 ************************
12 2016-08-05 14:10 44 *************************
13 2016-08-05 14:11 45 **************************
14 2016-08-05 14:12 45 **************************
15 2016-08-05 14:13 46 ***************************
16 2016-08-05 14:14 46 ***************************
17 2016-08-05 14:15 47 ****************************
... ..( 2 skipped). .. ****************************
20 2016-08-05 14:18 47 ****************************
21 2016-08-05 14:19 48 *****************************
22 2016-08-05 14:20 48 *****************************
23 2016-08-05 14:21 ? -
24 2016-08-05 14:22 48 *****************************
25 2016-08-05 14:23 ? -
26 2016-08-05 14:24 49 ******************************
27 2016-08-05 14:25 49 ******************************
28 2016-08-05 14:26 50 *******************************
... ..( 3 skipped). .. *******************************
32 2016-08-05 14:30 50 *******************************
33 2016-08-05 14:31 51 ********************************
... ..( 7 skipped). .. ********************************
41 2016-08-05 14:39 51 ********************************
42 2016-08-05 14:40 52 *********************************
... ..( 8 skipped). .. *********************************
51 2016-08-05 14:49 52 *********************************
52 2016-08-05 14:50 ? -
53 2016-08-05 14:51 52 *********************************
... ..( 28 skipped). .. *********************************
82 2016-08-05 15:20 52 *********************************
83 2016-08-05 15:21 53 **********************************
84 2016-08-05 15:22 53 **********************************
85 2016-08-05 15:23 ? -
86 2016-08-05 15:24 53 **********************************
... ..( 41 skipped). .. **********************************
0 2016-08-05 16:06 53 **********************************
1 2016-08-05 16:07 52 *********************************
2 2016-08-05 16:08 ? -
3 2016-08-05 16:09 53 **********************************
4 2016-08-05 16:10 52 *********************************
5 2016-08-05 16:11 52 *********************************
6 2016-08-05 16:12 52 *********************************
7 2016-08-05 16:13 53 **********************************
8 2016-08-05 16:14 53 **********************************
9 2016-08-05 16:15 52 *********************************
10 2016-08-05 16:16 52 *********************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x8000 4 447 Vendor specific