Probe #3c86eab683 of Dell 0NV0M7 A01 Desktop Computer (OptiPlex 3060)
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.9-desktop-1omv2490] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KBG40ZNS256G NVMe KIOXIA 256GB
Serial Number: --
Firmware Version: 10410106
PCI Vendor/Subsystem ID: 0x1e0f
IEEE OUI Identifier: 0x8ce38e
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 8ce38e ...
Local Time is: Sat Jan 18 20:16:57 2025 CST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 87 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 3.60W - - 0 0 0 0 1 1
1 + 2.60W - - 1 1 1 1 1 1
2 + 2.20W - - 2 2 2 2 1 1
3 - 0.0500W - - 3 3 3 3 800 1200
4 - 0.0050W - - 4 4 4 4 3000 32000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 3
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 32 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 18%
Data Units Read: 55,889,902 [28.6 TB]
Data Units Written: 54,808,231 [28.0 TB]
Host Read Commands: 1,131,174,314
Host Write Commands: 1,369,409,465
Controller Busy Time: 7,213
Power Cycles: 670
Power On Hours: 4,250
Unsafe Shutdowns: 5
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 32 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 1861 - - - - -
1 Short Aborted: Self-test command 1433 - - - - -
2 Short Completed without error 1239 - - - - -
3 Short Completed without error 1197 - - - - -
4 Short Completed without error 1196 - - - - -
5 Short Completed without error 950 - - - - -
6 Short Completed without error 612 - - - - -
7 Short Completed without error 13 - - - - -
8 Short Completed without error 7 - - - - -
9 Short Completed without error 3 - - - - -