/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.7-desktop-1omv4003] (OpenMandriva Lx 7.2-2)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.2
Device Model: ST96812A
Serial Number: --
Firmware Version: 3.06
User Capacity: 60,011,642,880 bytes [60.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Tue Jul 5 18:01:57 2022 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 426) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 84) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 111 095 006 - 33480447
3 Spin_Up_Time PO---- 097 096 000 - 0
4 Start_Stop_Count -O--CK 099 099 020 - 1972
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 074 060 030 - 28670317
9 Power_On_Hours -O--CK 099 099 000 - 1702
10 Spin_Retry_Count PO--C- 100 100 034 - 0
12 Power_Cycle_Count -O--CK 099 099 020 - 1942
187 Reported_Uncorrect -O--CK 001 001 000 - 173
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 060 054 045 - 40 (Min/Max 40/43)
192 Power-Off_Retract_Count -O--CK 100 100 000 - 276
193 Load_Cycle_Count -O--CK 047 047 000 - 106863
194 Temperature_Celsius -O---K 040 046 000 - 40 (0 8 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 084 051 000 - 140490784
197 Current_Pending_Sector -O--C- 001 001 000 - 4294967295
198 Offline_Uncorrectable ----C- 001 001 000 - 4294967295
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x20 SL R/O 1 Streaming performance log [OBS-8]
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 249 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 249 occurred at disk power-on lifetime: 1213 hours (50 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 15 da 43 e2
Error: UNC at LBA = 0x0243da15 = 38001173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 20 03 da 43 e2 00 00:18:08.646 READ DMA
c8 d8 20 e3 d9 43 e2 00 00:18:08.646 READ DMA
c8 d8 20 c3 d9 43 e2 00 00:18:08.645 READ DMA
c8 d8 20 a3 d9 43 e2 00 00:18:08.645 READ DMA
c8 d8 20 83 d9 43 e2 00 00:18:08.650 READ DMA
Error 248 occurred at disk power-on lifetime: 1213 hours (50 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 15 da 43 e2
Error: UNC at LBA = 0x0243da15 = 38001173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 80 c3 d9 43 e2 00 00:18:02.717 READ DMA
c8 d8 80 43 d9 43 e2 00 00:18:02.716 READ DMA
c8 d8 80 c3 d8 43 e2 00 00:18:02.740 READ DMA
c8 d8 80 43 d8 43 e2 00 00:18:02.738 READ DMA
c8 d8 80 c3 d7 43 e2 00 00:18:02.737 READ DMA
Error 247 occurred at disk power-on lifetime: 1213 hours (50 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 15 da 43 e2
Error: UNC at LBA = 0x0243da15 = 38001173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 08 13 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 4b da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 13 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 43 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 0b da 43 e2 00 00:03:57.757 READ DMA
Error 246 occurred at disk power-on lifetime: 1213 hours (50 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 15 da 43 e2
Error: UNC at LBA = 0x0243da15 = 38001173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 08 13 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 43 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 0b da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 03 da 43 e2 00 00:03:55.524 READ DMA
c8 d8 08 fb d9 43 e2 00 00:03:55.523 READ DMA
Error 245 occurred at disk power-on lifetime: 1213 hours (50 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 15 da 43 e2
Error: UNC at LBA = 0x0243da15 = 38001173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 00 4b d9 43 e2 00 00:03:53.043 READ DMA
c8 d8 00 4b d8 43 e2 00 00:03:53.040 READ DMA
c8 d8 00 4b d7 43 e2 00 00:03:53.037 READ DMA
c8 d8 00 4b d6 43 e2 00 00:03:53.032 READ DMA
c8 d8 00 4b d5 43 e2 00 00:03:53.029 READ DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 521 (0x0209)
Device State: Active (0)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: --/ 0 Celsius
Lifetime Min/Max Temperature: --/ 0 Celsius
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported