Probe #5600a75dba of HP EliteBook 735 G5
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.0.7-301.fc37.x86_64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KBG30ZMV256G TOSHIBA
Serial Number: --
Firmware Version: ADHA0101
PCI Vendor/Subsystem ID: 0x1179
IEEE OUI Identifier: 0x00080d
Controller ID: 0
NVMe Version: 1.2.1
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 00080d ...
Local Time is: Wed Oct 4 07:35:04 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0017): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
Log Page Attributes (0x02): Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 82 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 3.30W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.30W - - 2 2 2 2 0 0
3 - 0.0500W - - 4 4 4 4 8000 32000
4 - 0.0050W - - 4 4 4 4 8000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 - 4096 0 0
1 + 512 0 3
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 51 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 37%
Data Units Read: 32,284,511 [16.5 TB]
Data Units Written: 71,584,050 [36.6 TB]
Host Read Commands: 539,438,226
Host Write Commands: 1,224,622,382
Controller Busy Time: 8,071
Power Cycles: 1,958
Power On Hours: 13,625
Unsafe Shutdowns: 222
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,540
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 51 Celsius
Thermal Temp. 1 Transition Count: 8
Thermal Temp. 2 Transition Count: 5
Thermal Temp. 1 Total Time: 112
Thermal Temp. 2 Total Time: 5
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 1540 0 0x0008 0xc004 0x028 - 0 - Invalid Field in Command
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Extended Completed without error 10856 - - - - -