/dev/nvme0n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.11-arch1-1] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: XPG GAMMIX S41
Serial Number: --
Firmware Version: VB421D57
PCI Vendor/Subsystem ID: 0x10ec
IEEE OUI Identifier: 0x00e04c
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Mon Apr 11 07:41:23 2022 UTC
Firmware Updates (0x02): 1 Slot
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
Log Page Attributes (0x02): Cmd_Eff_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 118 Celsius
Critical Comp. Temp. Threshold: 150 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.00W - - 0 0 0 0 0 50000
1 + 4.00W - - 1 1 1 1 0 50000
2 + 3.00W - - 2 2 2 2 0 50000
3 - 0.0500W - - 3 3 3 3 4000 50000
4 - 0.0080W - - 4 4 4 4 8000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 42 Celsius
Available Spare: 100%
Available Spare Threshold: 32%
Percentage Used: 2%
Data Units Read: 13,157,793 [6.73 TB]
Data Units Written: 23,302,976 [11.9 TB]
Host Read Commands: 111,256,332
Host Write Commands: 123,255,388
Controller Busy Time: 0
Power Cycles: 663
Power On Hours: 6,218
Unsafe Shutdowns: 118
Media and Data Integrity Errors: 0
Error Information Log Entries: 587
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 8 of 8 entries)
No Errors Logged
/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.11-arch1-1] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Toshiba P300
Device Model: TOSHIBA HDWD110
Serial Number: --
LU WWN Device Id: 5 000039 ...
Firmware Version: MS2OA8R0
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Apr 11 07:41:23 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7022) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 117) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 142 142 054 - 68
3 Spin_Up_Time POS--- 127 127 024 - 181 (Average 180)
4 Start_Stop_Count -O--C- 099 099 000 - 7574
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 110 110 020 - 36
9 Power_On_Hours -O--C- 098 098 000 - 16686
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1622
192 Power-Off_Retract_Count -O--CK 094 094 000 - 7607
193 Load_Cycle_Count -O--C- 094 094 000 - 7607
194 Temperature_Celsius -O---- 162 162 000 - 37 (Min/Max 15/41)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 23/38 Celsius
Lifetime Min/Max Temperature: 15/41 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (109)
Index Estimated Time Temperature Celsius
110 2022-04-11 05:34 28 *********
111 2022-04-11 05:35 28 *********
112 2022-04-11 05:36 29 **********
... ..( 2 skipped). .. **********
115 2022-04-11 05:39 29 **********
116 2022-04-11 05:40 30 ***********
117 2022-04-11 05:41 30 ***********
118 2022-04-11 05:42 31 ************
... ..( 4 skipped). .. ************
123 2022-04-11 05:47 31 ************
124 2022-04-11 05:48 32 *************
... ..( 3 skipped). .. *************
0 2022-04-11 05:52 32 *************
1 2022-04-11 05:53 33 **************
... ..( 3 skipped). .. **************
5 2022-04-11 05:57 33 **************
6 2022-04-11 05:58 32 *************
... ..( 4 skipped). .. *************
11 2022-04-11 06:03 32 *************
12 2022-04-11 06:04 33 **************
... ..( 6 skipped). .. **************
19 2022-04-11 06:11 33 **************
20 2022-04-11 06:12 34 ***************
... ..( 9 skipped). .. ***************
30 2022-04-11 06:22 34 ***************
31 2022-04-11 06:23 35 ****************
32 2022-04-11 06:24 34 ***************
33 2022-04-11 06:25 35 ****************
... ..( 8 skipped). .. ****************
42 2022-04-11 06:34 35 ****************
43 2022-04-11 06:35 36 *****************
... ..( 18 skipped). .. *****************
62 2022-04-11 06:54 36 *****************
63 2022-04-11 06:55 37 ******************
... ..( 5 skipped). .. ******************
69 2022-04-11 07:01 37 ******************
70 2022-04-11 07:02 38 *******************
71 2022-04-11 07:03 37 ******************
... ..( 17 skipped). .. ******************
89 2022-04-11 07:21 37 ******************
90 2022-04-11 07:22 36 *****************
91 2022-04-11 07:23 37 ******************
... ..( 6 skipped). .. ******************
98 2022-04-11 07:30 37 ******************
99 2022-04-11 07:31 36 *****************
100 2022-04-11 07:32 36 *****************
101 2022-04-11 07:33 36 *****************
102 2022-04-11 07:34 37 ******************
... ..( 2 skipped). .. ******************
105 2022-04-11 07:37 37 ******************
106 2022-04-11 07:38 36 *****************
... ..( 2 skipped). .. *****************
109 2022-04-11 07:41 36 *****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1622 --- Lifetime Power-On Resets
0x01 0x010 4 16686 --- Power-on Hours
0x01 0x018 6 22910967058 --- Logical Sectors Written
0x01 0x020 6 124140420 --- Number of Write Commands
0x01 0x028 6 1265525787008 --- Logical Sectors Read
0x01 0x030 6 159440438 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 14384 --- Spindle Motor Power-on Hours
0x03 0x010 4 14383 --- Head Flying Hours
0x03 0x018 4 7607 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 3 --- Read Recovery Attempts
0x03 0x030 4 2 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 37 --- Current Temperature
0x05 0x010 1 32 N-- Average Short Term Temperature
0x05 0x018 1 31 N-- Average Long Term Temperature
0x05 0x020 1 41 --- Highest Temperature
0x05 0x028 1 15 --- Lowest Temperature
0x05 0x030 1 35 N-- Highest Average Short Term Temperature
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
0x05 0x040 1 33 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 12533 --- Number of Hardware Resets
0x06 0x010 4 6172 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.11-arch1-1] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: SanDisk SDSSDA480G
Serial Number: --
LU WWN Device Id: 5 001b44 ...
Firmware Version: Z32070RL
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Apr 11 07:41:25 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Retired_Block_Count -O--CK 100 100 000 - 0
9 Power_On_Hours_and_Msec -O--CK 000 100 000 - 24556h+00m+00.000s
12 Power_Cycle_Count -O--CK 100 100 000 - 2608
165 Unknown_Attribute -O--CK 100 100 000 - 12155354227185
166 Unknown_Attribute -O--CK 100 100 000 - 49
167 Unknown_Attribute -O--CK 100 100 000 - 0
168 Unknown_Attribute -O--CK 100 100 000 - 99
169 Unknown_Attribute -O--CK 100 100 000 - 0
170 Reserve_Block_Count -O--CK 100 100 000 - 0
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Unknown_SandForce_Attr -O--CK 100 100 000 - 77
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 356
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 071 025 000 - 29 (Min/Max 0/75)
199 SATA_CRC_Error_Count -O--CK 100 100 000 - 0
230 Life_Curve_Status -O--CK 100 100 000 - 12438297971536
232 Available_Reservd_Space PO--CK 100 100 004 - 100
233 SandForce_Internal -O--CK 100 100 000 - 37170
234 SandForce_Internal -O--CK 100 100 000 - 175411
241 Lifetime_Writes_GiB ----CK 253 253 000 - 62343
242 Lifetime_Reads_GiB ----CK 253 253 000 - 59387
244 Unknown_Attribute -O--CK 000 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xde GPL VS 8 Device vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2608 --- Lifetime Power-On Resets
0x01 0x010 4 24556 --- Power-on Hours
0x01 0x018 6 1895506931 --- Logical Sectors Written
0x01 0x020 6 1776826805 --- Number of Write Commands
0x01 0x028 6 4285513617 --- Logical Sectors Read
0x01 0x030 6 1516402673 --- Number of Read Commands
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x000a 4 10 Device-to-host register FISes sent due to a COMRESET
/dev/sdc
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.11-arch1-1] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.6
Device Model: ST9500325AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: D005DEM1
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Mon Apr 11 07:41:25 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 208 (intermediate), recommended: 208
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 137) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 115 099 006 - 94609469
3 Spin_Up_Time PO---- 099 098 085 - 0
4 Start_Stop_Count -O--CK 084 084 020 - 16567
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 081 060 030 - 159788376
9 Power_On_Hours -O--CK 063 063 000 - 32566
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 095 095 020 - 5317
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 096 000 - 4295032892
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 061 050 045 - 39 (Min/Max 24/39)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 48
192 Power-Off_Retract_Count -O--CK 100 100 000 - 22
193 Load_Cycle_Count -O--CK 001 001 000 - 341046
194 Temperature_Celsius -O---K 039 050 000 - 39 (0 17 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 048 041 000 - 94609469
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 8644 (234 91 0)
241 Total_LBAs_Written ------ 100 253 000 - 444956259
242 Total_LBAs_Read ------ 100 253 000 - 3016688788
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 65 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xb0 GPL VS 2864 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3976 -
# 2 Short offline Completed without error 00% 1755 -
# 3 Short offline Completed without error 00% 1456 -
# 4 Short offline Completed without error 00% 1336 -
# 5 Short offline Completed without error 00% 1182 -
# 6 Short offline Completed without error 00% 2 -
# 7 Short offline Completed without error 00% 1 -
# 8 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 24/40 Celsius
Lifetime Min/Max Temperature: 17/50 Celsius
Specified Max Operating Temperature: 35 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (18)
Index Estimated Time Temperature Celsius
19 2022-04-11 05:34 35 ****************
... ..( 3 skipped). .. ****************
23 2022-04-11 05:38 35 ****************
24 2022-04-11 05:39 31 ************
25 2022-04-11 05:40 31 ************
26 2022-04-11 05:41 32 *************
27 2022-04-11 05:42 32 *************
28 2022-04-11 05:43 33 **************
29 2022-04-11 05:44 33 **************
30 2022-04-11 05:45 34 ***************
... ..( 2 skipped). .. ***************
33 2022-04-11 05:48 34 ***************
34 2022-04-11 05:49 35 ****************
... ..( 3 skipped). .. ****************
38 2022-04-11 05:53 35 ****************
39 2022-04-11 05:54 36 *****************
... ..( 6 skipped). .. *****************
46 2022-04-11 06:01 36 *****************
47 2022-04-11 06:02 37 ******************
... ..( 13 skipped). .. ******************
61 2022-04-11 06:16 37 ******************
62 2022-04-11 06:17 38 *******************
63 2022-04-11 06:18 38 *******************
64 2022-04-11 06:19 38 *******************
65 2022-04-11 06:20 35 ****************
66 2022-04-11 06:21 36 *****************
67 2022-04-11 06:22 36 *****************
68 2022-04-11 06:23 37 ******************
... ..( 3 skipped). .. ******************
72 2022-04-11 06:27 37 ******************
73 2022-04-11 06:28 38 *******************
... ..( 10 skipped). .. *******************
84 2022-04-11 06:39 38 *******************
85 2022-04-11 06:40 39 ********************
... ..( 30 skipped). .. ********************
116 2022-04-11 07:11 39 ********************
117 2022-04-11 07:12 40 *********************
118 2022-04-11 07:13 39 ********************
119 2022-04-11 07:14 40 *********************
120 2022-04-11 07:15 39 ********************
... ..( 25 skipped). .. ********************
18 2022-04-11 07:41 39 ********************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS