Probe #57d30cfce9 of Lenovo IdeaPad 3 15IML05 82...

Log: smartctl

/dev/nvme0n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-31-generic] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: KINGSTON SNV2S1000G Serial Number: -- Firmware Version: ELFK0S.6 PCI Vendor/Subsystem ID: 0x2646 IEEE OUI Identifier: 0x0026b7 Total NVM Capacity: 1,000,204,886,016 [1.00 TB] Unallocated NVM Capacity: 0 Controller ID: 0 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 0026b7 ... Local Time is: Fri May 17 09:20:28 2024 -03 Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x0057): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 77 Celsius Critical Comp. Temp. Threshold: 79 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 5.00W - - 0 0 0 0 0 0 1 + 2.40W - - 1 1 1 1 0 0 2 + 1.90W - - 2 2 2 2 0 0 3 - 0.0500W - - 3 3 3 3 3000 2000 4 - 0.0035W - - 4 4 4 4 10000 40000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 25 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 3,934,593 [2.01 TB] Data Units Written: 6,487,052 [3.32 TB] Host Read Commands: 64,683,109 Host Write Commands: 117,062,583 Controller Busy Time: 231 Power Cycles: 417 Power On Hours: 254 Unsafe Shutdowns: 12 Media and Data Integrity Errors: 0 Error Information Log Entries: 5,027 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 2: 52 Celsius Error Information (NVMe Log 0x01, 16 of 63 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message 0 5027 0 0x400d 0xc004 0x000 0 0 - Invalid Field in Command 1 5026 0 0x400c 0xc004 0x000 0 0 - Invalid Field in Command 2 5025 0 0x000c 0xc005 0x028 0 0 - Invalid Field in Command 3 5024 0 0x1008 0xc005 - 0 0 - Invalid Field in Command Read Self-test Log failed: Invalid Field in Command (0x6002)


Hardware for Linux and BSD

GitHub