/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.20-generic-2rosa2021.1-x86_64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Intel 520 Series SSDs
Device Model: INTEL SSDSC2CW120A3
Serial Number: --
LU WWN Device Id: 5 5cd2e4 ...
Firmware Version: 400i
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available, deterministic
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu May 25 06:41:10 2023 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2097) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 911142h+10m+02.760s
12 Power_Cycle_Count -O--CK 093 093 000 - 7361
170 Available_Reservd_Space PO--CK 100 100 010 - 0
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 5677
184 End-to-End_Error PO--CK 100 100 090 - 0
187 Uncorrectable_Error_Cnt POSR-- 105 105 050 - 10197601
192 Power-Off_Retract_Count -O--CK 100 100 000 - 5677
225 Host_Writes_32MiB -O--CK 100 100 000 - 333649
226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 65535
227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 68
228 Workload_Minutes -O--CK 100 100 000 - 65535
232 Available_Reservd_Space PO--CK 100 100 010 - 0
233 Media_Wearout_Indicator -O--CK 100 100 000 - 0
241 Host_Writes_32MiB -O--CK 100 100 000 - 333649
242 Host_Reads_32MiB -O--CK 100 100 000 - 739204
249 NAND_Writes_1GiB PO--C- 100 100 000 - 13090
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x04 GPL,SL R/O 1 Device Statistics log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 0 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/30 Celsius
Lifetime Min/Max Temperature: 30/30 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 0 (Unknown, should be 2)
Temperature Sampling Period: 0 minutes
Temperature Logging Interval: 0 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 0 (0)
Temperature History is empty
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 7378 --- Lifetime Power-On Resets
0x01 0x010 4 16348 --- Power-on Hours
0x01 0x018 6 23195139336 --- Logical Sectors Written
0x01 0x028 6 49990776848 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 25916 --- Resets Between Cmd Acceptance and Completion
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 25916 --- Number of Hardware Resets
0x06 0x010 4 19040 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 255 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 16 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.20-generic-2rosa2021.1-x86_64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST500LM012 HN-M500MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2BA30001
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu May 25 06:41:11 2023 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7080) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 118) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 79
2 Throughput_Performance POS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 094 087 025 - 1844
4 Start_Stop_Count -O--CK 098 098 000 - 2050
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate POSR-K 252 252 051 - 0
8 Seek_Time_Performance P-S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 21249
10 Spin_Retry_Count PO--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 326
12 Power_Cycle_Count -O--CK 099 099 000 - 2003
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 20286858
183 Runtime_Bad_Block -O--CK 100 100 010 - 69
184 End-to-End_Error PO--CK 252 252 048 - 0
186 Unknown_Attribute -O--CK 252 252 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 2
188 Command_Timeout -O--CK 252 252 000 - 0
190 Airflow_Temperature_Cel -O---- 063 055 040 - 37 (Min/Max -4/46)
191 G-Sense_Error_Rate -O---K 100 100 000 - 1625
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
193 Load_Cycle_Count -O--CK 011 011 000 - 900182
194 Temperature_Celsius -O---- 063 055 000 - 37 (Min/Max -4/46)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 252 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 315016
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 21149 hours (881 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 08 00 00 04 54 a2 50 40 00
Error: UNC at LBA = 0x0454a250 = 72655440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.030 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:00:00.030 READ LOG EXT
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.024 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 21149 hours (881 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 08 00 00 04 54 a2 50 40 00
Error: UNC at LBA = 0x0454a250 = 72655440
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 54 a2 50 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 71 82 28 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 71 82 20 40 00 00:00:00.024 READ FPDMA QUEUED
60 00 00 00 08 00 00 04 54 a2 38 40 00 00:00:00.024 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 34/37 Celsius
Lifetime Min/Max Temperature: -4/46 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (107)
Index Estimated Time Temperature Celsius
108 2023-05-24 20:05 36 *****************
109 2023-05-24 20:10 41 **********************
110 2023-05-24 20:15 40 *********************
111 2023-05-24 20:20 40 *********************
112 2023-05-24 20:25 41 **********************
113 2023-05-24 20:30 41 **********************
114 2023-05-24 20:35 41 **********************
115 2023-05-24 20:40 40 *********************
116 2023-05-24 20:45 41 **********************
117 2023-05-24 20:50 41 **********************
118 2023-05-24 20:55 41 **********************
119 2023-05-24 21:00 42 ***********************
... ..( 26 skipped). .. ***********************
18 2023-05-24 23:15 42 ***********************
19 2023-05-24 23:20 43 ************************
20 2023-05-24 23:25 43 ************************
21 2023-05-24 23:30 43 ************************
22 2023-05-24 23:35 37 ******************
23 2023-05-24 23:40 40 *********************
24 2023-05-24 23:45 41 **********************
25 2023-05-24 23:50 42 ***********************
... ..( 2 skipped). .. ***********************
28 2023-05-25 00:05 42 ***********************
29 2023-05-25 00:10 41 **********************
30 2023-05-25 00:15 41 **********************
31 2023-05-25 00:20 42 ***********************
... ..( 4 skipped). .. ***********************
36 2023-05-25 00:45 42 ***********************
37 2023-05-25 00:50 43 ************************
38 2023-05-25 00:55 42 ***********************
39 2023-05-25 01:00 42 ***********************
40 2023-05-25 01:05 42 ***********************
41 2023-05-25 01:10 43 ************************
... ..( 4 skipped). .. ************************
46 2023-05-25 01:35 43 ************************
47 2023-05-25 01:40 42 ***********************
48 2023-05-25 01:45 42 ***********************
49 2023-05-25 01:50 42 ***********************
50 2023-05-25 01:55 43 ************************
... ..( 6 skipped). .. ************************
57 2023-05-25 02:30 43 ************************
58 2023-05-25 02:35 42 ***********************
... ..( 2 skipped). .. ***********************
61 2023-05-25 02:50 42 ***********************
62 2023-05-25 02:55 40 *********************
63 2023-05-25 03:00 39 ********************
64 2023-05-25 03:05 39 ********************
65 2023-05-25 03:10 39 ********************
66 2023-05-25 03:15 40 *********************
67 2023-05-25 03:20 41 **********************
68 2023-05-25 03:25 41 **********************
69 2023-05-25 03:30 41 **********************
70 2023-05-25 03:35 42 ***********************
... ..( 3 skipped). .. ***********************
74 2023-05-25 03:55 42 ***********************
75 2023-05-25 04:00 37 ******************
76 2023-05-25 04:05 40 *********************
77 2023-05-25 04:10 41 **********************
78 2023-05-25 04:15 42 ***********************
... ..( 2 skipped). .. ***********************
81 2023-05-25 04:30 42 ***********************
82 2023-05-25 04:35 43 ************************
... ..( 8 skipped). .. ************************
91 2023-05-25 05:20 43 ************************
92 2023-05-25 05:25 30 ***********
93 2023-05-25 05:30 31 ************
94 2023-05-25 05:35 32 *************
95 2023-05-25 05:40 34 ***************
96 2023-05-25 05:45 35 ****************
97 2023-05-25 05:50 34 ***************
... ..( 3 skipped). .. ***************
101 2023-05-25 06:10 34 ***************
102 2023-05-25 06:15 35 ****************
103 2023-05-25 06:20 35 ****************
104 2023-05-25 06:25 36 *****************
... ..( 2 skipped). .. *****************
107 2023-05-25 06:40 36 *****************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 139 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific