/dev/sda
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.14.6-2-cachyos] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: WD Blue / Red / Green SSDs
Device Model: WDC WDS250G2B0B-00YS70
Serial Number: --
LU WWN Device Id: 5 001b44 ...
Firmware Version: 401000WD
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: M.2
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.5/5706
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 17 19:14:55 2025 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 100 100 --- - 0
9 Power_On_Hours -O--CK 100 100 --- - 10249
12 Power_Cycle_Count -O--CK 100 100 --- - 1796
165 Block_Erase_Count -O--CK 100 100 --- - 451259404200
166 Minimum_PE_Cycles_TLC -O--CK 100 100 --- - 16
167 Max_Bad_Blocks_per_Die -O--CK 100 100 --- - 27
168 Maximum_PE_Cycles_TLC -O--CK 100 100 --- - 69
169 Total_Bad_Blocks -O--CK 100 100 --- - 132
170 Grown_Bad_Blocks -O--CK 100 100 --- - 0
171 Program_Fail_Count -O--CK 100 100 --- - 0
172 Erase_Fail_Count -O--CK 100 100 --- - 0
173 Average_PE_Cycles_TLC -O--CK 100 100 --- - 46
174 Unexpected_Power_Loss -O--CK 100 100 --- - 41
184 End-to-End_Error -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 --- - 0
188 Command_Timeout -O--CK 100 100 --- - 1
194 Temperature_Celsius -O---K 054 066 --- - 46 (Min/Max 15/66)
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
230 Media_Wearout_Indicator -O--CK 008 008 --- - 0x0801043c0801
232 Available_Reservd_Space PO--CK 100 100 004 - 100
233 NAND_GB_Written_TLC -O--CK 100 100 --- - 11691
234 NAND_GB_Written_SLC -O--CK 100 100 --- - 23830
241 Host_Writes_GiB ----CK 253 253 --- - 17943
242 Host_Reads_GiB ----CK 253 253 --- - 20320
244 Temp_Throttle_Status -O--CK 000 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 1781 Current Device Internal Status Data log
0x25 GPL R/O 1781 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xde GPL VS 8 Device vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 10232 -
# 2 Short offline Completed without error 00% 9602 -
# 3 Short offline Completed without error 00% 8190 -
# 4 Short offline Completed without error 00% 7840 -
# 5 Short offline Completed without error 00% 7698 -
# 6 Short offline Completed without error 00% 7389 -
# 7 Short offline Completed without error 00% 7095 -
# 8 Short offline Completed without error 00% 6759 -
# 9 Short offline Completed without error 00% 6449 -
#10 Short offline Completed without error 00% 6203 -
#11 Short offline Completed without error 00% 5745 -
#12 Short offline Completed without error 00% 5473 -
#13 Short offline Completed without error 00% 5309 -
#14 Short offline Completed without error 00% 4926 -
#15 Short offline Completed without error 00% 4551 -
#16 Short offline Completed without error 00% 4127 -
#17 Short offline Completed without error 00% 2614 -
#18 Short offline Completed without error 00% 2226 -
#19 Short offline Completed without error 00% 2009 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1796 --- Lifetime Power-On Resets
0x01 0x010 4 10249 --- Power-on Hours
0x01 0x018 6 37629425692 --- Logical Sectors Written
0x01 0x020 6 502638685 --- Number of Write Commands
0x01 0x028 6 42616169631 --- Logical Sectors Read
0x01 0x030 6 520272048892 --- Number of Read Commands
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
/dev/sdb
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.14.6-2-cachyos] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue Mobile
Device Model: WDC WD10JPVX-22JC3T0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.5/5706
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 17 19:14:55 2025 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (18420) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 206) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 181 176 021 - 1950
4 Start_Stop_Count -O--CK 001 001 000 - 490798
5 Reallocated_Sector_Ct PO--CK 199 199 140 - 62
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 068 068 000 - 23649
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2133
191 G-Sense_Error_Rate -O--CK 020 020 000 - 80
192 Power-Off_Retract_Count -O--CK 200 200 000 - 311
193 Load_Cycle_Count -O--CK 001 001 000 - 1355064
194 Temperature_Celsius -O---K 104 094 000 - 43
196 Reallocated_Event_Count -O--CK 138 138 000 - 62
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 38 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 23643 -
# 2 Short offline Completed without error 00% 23367 -
# 3 Short offline Completed without error 00% 22586 -
# 4 Short offline Completed without error 00% 22387 -
# 5 Short offline Completed without error 00% 22316 -
# 6 Short offline Completed without error 00% 22220 -
# 7 Short offline Aborted by host 80% 22163 -
# 8 Short offline Completed without error 00% 22140 -
# 9 Short offline Completed without error 00% 22001 -
#10 Short offline Completed without error 00% 21863 -
#11 Short offline Completed without error 00% 21737 -
#12 Short offline Completed without error 00% 21515 -
#13 Short offline Completed without error 00% 21318 -
#14 Short offline Completed without error 00% 21226 -
#15 Short offline Completed without error 00% 21041 -
#16 Short offline Completed without error 00% 20972 -
#17 Short offline Completed without error 00% 20896 -
#18 Short offline Completed without error 00% 20360 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 41/43 Celsius
Lifetime Min/Max Temperature: 13/55 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (26)
Index Estimated Time Temperature Celsius
27 2025-05-17 17:07 40 *********************
28 2025-05-17 17:08 40 *********************
29 2025-05-17 17:09 41 **********************
... ..( 9 skipped). .. **********************
39 2025-05-17 17:19 41 **********************
40 2025-05-17 17:20 ? -
41 2025-05-17 17:21 25 ******
42 2025-05-17 17:22 26 *******
43 2025-05-17 17:23 27 ********
44 2025-05-17 17:24 27 ********
45 2025-05-17 17:25 28 *********
46 2025-05-17 17:26 29 **********
47 2025-05-17 17:27 29 **********
48 2025-05-17 17:28 30 ***********
49 2025-05-17 17:29 30 ***********
50 2025-05-17 17:30 31 ************
51 2025-05-17 17:31 31 ************
52 2025-05-17 17:32 32 *************
53 2025-05-17 17:33 32 *************
54 2025-05-17 17:34 33 **************
55 2025-05-17 17:35 33 **************
56 2025-05-17 17:36 34 ***************
57 2025-05-17 17:37 34 ***************
58 2025-05-17 17:38 35 ****************
... ..( 3 skipped). .. ****************
62 2025-05-17 17:42 35 ****************
63 2025-05-17 17:43 36 *****************
64 2025-05-17 17:44 36 *****************
65 2025-05-17 17:45 36 *****************
66 2025-05-17 17:46 37 ******************
67 2025-05-17 17:47 37 ******************
68 2025-05-17 17:48 37 ******************
69 2025-05-17 17:49 38 *******************
... ..( 2 skipped). .. *******************
72 2025-05-17 17:52 38 *******************
73 2025-05-17 17:53 39 ********************
... ..( 2 skipped). .. ********************
76 2025-05-17 17:56 39 ********************
77 2025-05-17 17:57 40 *********************
... ..( 9 skipped). .. *********************
87 2025-05-17 18:07 40 *********************
88 2025-05-17 18:08 41 **********************
... ..( 4 skipped). .. **********************
93 2025-05-17 18:13 41 **********************
94 2025-05-17 18:14 ? -
95 2025-05-17 18:15 27 ********
96 2025-05-17 18:16 27 ********
97 2025-05-17 18:17 28 *********
98 2025-05-17 18:18 29 **********
99 2025-05-17 18:19 30 ***********
100 2025-05-17 18:20 30 ***********
101 2025-05-17 18:21 30 ***********
102 2025-05-17 18:22 31 ************
103 2025-05-17 18:23 32 *************
104 2025-05-17 18:24 32 *************
105 2025-05-17 18:25 33 **************
106 2025-05-17 18:26 33 **************
107 2025-05-17 18:27 34 ***************
108 2025-05-17 18:28 34 ***************
109 2025-05-17 18:29 35 ****************
... ..( 2 skipped). .. ****************
112 2025-05-17 18:32 35 ****************
113 2025-05-17 18:33 36 *****************
114 2025-05-17 18:34 36 *****************
115 2025-05-17 18:35 36 *****************
116 2025-05-17 18:36 37 ******************
117 2025-05-17 18:37 37 ******************
118 2025-05-17 18:38 37 ******************
119 2025-05-17 18:39 38 *******************
120 2025-05-17 18:40 38 *******************
121 2025-05-17 18:41 39 ********************
122 2025-05-17 18:42 39 ********************
123 2025-05-17 18:43 39 ********************
124 2025-05-17 18:44 40 *********************
... ..( 4 skipped). .. *********************
1 2025-05-17 18:49 40 *********************
2 2025-05-17 18:50 ? -
3 2025-05-17 18:51 41 **********************
... ..( 8 skipped). .. **********************
12 2025-05-17 19:00 41 **********************
13 2025-05-17 19:01 42 ***********************
... ..( 11 skipped). .. ***********************
25 2025-05-17 19:13 42 ***********************
26 2025-05-17 19:14 43 ************************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 469 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 1439 Vendor specific