Probe #5c4e8748ef of IBM ThinkPad T40 237342G
Log: smartctl
/dev/sda
smartctl 7.2 2020-12-30 r5155 [i686-linux-4.9.0-279-antix.1-486-smp] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue EIDE
Device Model: WDC WD1200BEVE-00A0HT0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 11.01A11
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5
Local Time is: Sun Jan 16 07:55:16 2022 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4560) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x2037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 159 158 021 - 1041
4 Start_Stop_Count -O--CK 100 100 000 - 477
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 098 098 000 - 1511
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 311
192 Power-Off_Retract_Count -O--CK 200 200 000 - 42
193 Load_Cycle_Count -O--CK 200 200 000 - 842
194 Temperature_Celsius -O---K 111 094 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 32/35 Celsius
Lifetime Min/Max Temperature: 32/49 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 1/85 Celsius
Temperature History Size (Index): 128 (95)
Index Estimated Time Temperature Celsius
96 2022-01-16 05:48 38 *******************
... ..( 4 skipped). .. *******************
101 2022-01-16 05:53 38 *******************
102 2022-01-16 05:54 39 ********************
... ..( 24 skipped). .. ********************
127 2022-01-16 06:19 39 ********************
0 2022-01-16 06:20 40 *********************
... ..( 2 skipped). .. *********************
3 2022-01-16 06:23 40 *********************
4 2022-01-16 06:24 39 ********************
... ..( 6 skipped). .. ********************
11 2022-01-16 06:31 39 ********************
12 2022-01-16 06:32 ? -
13 2022-01-16 06:33 17 -
14 2022-01-16 06:34 18 -
15 2022-01-16 06:35 18 -
16 2022-01-16 06:36 18 -
17 2022-01-16 06:37 19 -
18 2022-01-16 06:38 ? -
19 2022-01-16 06:39 20 *
20 2022-01-16 06:40 ? -
21 2022-01-16 06:41 21 **
22 2022-01-16 06:42 21 **
23 2022-01-16 06:43 22 ***
24 2022-01-16 06:44 ? -
25 2022-01-16 06:45 22 ***
26 2022-01-16 06:46 22 ***
27 2022-01-16 06:47 22 ***
28 2022-01-16 06:48 23 ****
29 2022-01-16 06:49 ? -
30 2022-01-16 06:50 24 *****
... ..( 5 skipped). .. *****
36 2022-01-16 06:56 24 *****
37 2022-01-16 06:57 ? -
38 2022-01-16 06:58 24 *****
39 2022-01-16 06:59 24 *****
40 2022-01-16 07:00 ? -
41 2022-01-16 07:01 25 ******
42 2022-01-16 07:02 26 *******
43 2022-01-16 07:03 26 *******
44 2022-01-16 07:04 27 ********
45 2022-01-16 07:05 27 ********
46 2022-01-16 07:06 28 *********
47 2022-01-16 07:07 29 **********
48 2022-01-16 07:08 29 **********
49 2022-01-16 07:09 30 ***********
50 2022-01-16 07:10 30 ***********
51 2022-01-16 07:11 31 ************
52 2022-01-16 07:12 31 ************
53 2022-01-16 07:13 31 ************
54 2022-01-16 07:14 32 *************
55 2022-01-16 07:15 33 **************
56 2022-01-16 07:16 32 *************
57 2022-01-16 07:17 32 *************
58 2022-01-16 07:18 33 **************
59 2022-01-16 07:19 33 **************
60 2022-01-16 07:20 33 **************
61 2022-01-16 07:21 34 ***************
62 2022-01-16 07:22 34 ***************
63 2022-01-16 07:23 34 ***************
64 2022-01-16 07:24 35 ****************
... ..( 14 skipped). .. ****************
79 2022-01-16 07:39 35 ****************
80 2022-01-16 07:40 36 *****************
... ..( 2 skipped). .. *****************
83 2022-01-16 07:43 36 *****************
84 2022-01-16 07:44 ? -
85 2022-01-16 07:45 ? -
86 2022-01-16 07:46 35 ****************
87 2022-01-16 07:47 34 ***************
88 2022-01-16 07:48 34 ***************
89 2022-01-16 07:49 33 **************
90 2022-01-16 07:50 33 **************
91 2022-01-16 07:51 32 *************
... ..( 3 skipped). .. *************
95 2022-01-16 07:55 32 *************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported