/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-5.10.118-generic-2rosa2021.1-x86_64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi/HGST Travelstar 5K750
Device Model: Hitachi HTS547550A9E384
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: JE3OA50B
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Thu Jul 7 23:30:03 2022 +04
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 45) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 137) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
2 Throughput_Performance P-S--- 197 197 040 - 153
3 Spin_Up_Time POS--- 186 186 033 - 1
4 Start_Stop_Count -O--C- 099 099 000 - 2328
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 115 115 040 - 34
9 Power_On_Hours -O--C- 077 077 000 - 10206
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 2277
160 Unknown_Attribute PO-RCK 100 100 001 - 0
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 1
192 Power-Off_Retract_Count -O--CK 099 099 000 - 296
193 Load_Cycle_Count -O--C- 073 073 000 - 272009
194 Temperature_Celsius -O---- 162 162 000 - 37 (Min/Max 11/45)
196 Reallocated_Event_Count -O--CK 100 100 000 - 8
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 4
223 Load_Retry_Count -O-R-- 100 100 000 - 0
254 Free_Fall_Sensor -O--CK 100 100 000 - 194
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 4
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 4 [3] occurred at disk power-on lifetime: 5623 hours (234 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 05 60 00 00 06 10 11 50 06 00
Error: ICRC, ABRT at LBA = 0x06101150 = 101716304
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 e8 00 00 06 0e f7 60 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 06 90 00 e0 00 00 06 0e f0 d0 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 09 68 00 d8 00 00 06 0e e7 68 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 08 08 00 d0 00 00 06 10 27 f8 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 01 e0 00 c8 00 00 06 10 1e 20 40 00 07:36:00.637 WRITE FPDMA QUEUED
Error 3 [2] occurred at disk power-on lifetime: 5623 hours (234 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 04 e0 00 00 06 10 11 d0 06 00
Error: ICRC, ABRT at LBA = 0x061011d0 = 101716432
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 e8 00 00 06 0e f7 60 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 06 90 00 e0 00 00 06 0e f0 d0 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 09 68 00 d8 00 00 06 0e e7 68 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 08 08 00 d0 00 00 06 10 27 f8 40 00 07:36:00.638 WRITE FPDMA QUEUED
61 01 e0 00 c8 00 00 06 10 1e 20 40 00 07:36:00.637 WRITE FPDMA QUEUED
Error 2 [1] occurred at disk power-on lifetime: 3331 hours (138 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 11 00 00 00 24 ba 69 00 00
Error: ICRC, ABRT at LBA = 0x0024ba69 = 2407017
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 39 00 30 00 00 00 24 b3 9a 40 00 00:01:22.008 READ FPDMA QUEUED
60 00 20 00 58 00 00 00 24 b0 0a 40 00 00:01:21.991 READ FPDMA QUEUED
60 00 3b 00 28 00 00 00 1e b4 fa 40 00 00:01:21.990 READ FPDMA QUEUED
60 00 08 00 50 00 00 00 14 43 aa 40 00 00:01:21.982 READ FPDMA QUEUED
60 00 18 00 28 00 00 00 1e b4 6a 40 00 00:01:21.980 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 2856 hours (119 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 11 00 00 01 49 32 c7 01 00
Error: ICRC, ABRT at LBA = 0x014932c7 = 21574343
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 20 00 00 00 00 01 49 32 b8 40 00 00:36:43.960 READ FPDMA QUEUED
60 00 80 00 08 00 00 01 49 38 e0 40 00 00:36:43.956 READ FPDMA QUEUED
60 00 18 00 00 00 00 01 49 38 c8 40 00 00:36:43.956 READ FPDMA QUEUED
60 00 20 00 00 00 00 01 49 38 a8 40 00 00:36:43.955 READ FPDMA QUEUED
60 00 20 00 00 00 00 01 49 38 88 40 00 00:36:43.955 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 26/37 Celsius
Lifetime Min/Max Temperature: 11/45 Celsius
Specified Max Operating Temperature: 33 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (53)
Index Estimated Time Temperature Celsius
54 2022-07-07 21:23 34 ***************
... ..( 5 skipped). .. ***************
60 2022-07-07 21:29 34 ***************
61 2022-07-07 21:30 ? -
62 2022-07-07 21:31 26 *******
63 2022-07-07 21:32 26 *******
64 2022-07-07 21:33 27 ********
65 2022-07-07 21:34 28 *********
66 2022-07-07 21:35 28 *********
67 2022-07-07 21:36 29 **********
68 2022-07-07 21:37 30 ***********
69 2022-07-07 21:38 31 ************
70 2022-07-07 21:39 31 ************
71 2022-07-07 21:40 32 *************
... ..( 2 skipped). .. *************
74 2022-07-07 21:43 32 *************
75 2022-07-07 21:44 33 **************
76 2022-07-07 21:45 33 **************
77 2022-07-07 21:46 33 **************
78 2022-07-07 21:47 34 ***************
79 2022-07-07 21:48 34 ***************
80 2022-07-07 21:49 34 ***************
81 2022-07-07 21:50 35 ****************
82 2022-07-07 21:51 35 ****************
83 2022-07-07 21:52 35 ****************
84 2022-07-07 21:53 34 ***************
85 2022-07-07 21:54 35 ****************
... ..( 4 skipped). .. ****************
90 2022-07-07 21:59 35 ****************
91 2022-07-07 22:00 36 *****************
... ..( 6 skipped). .. *****************
98 2022-07-07 22:07 36 *****************
99 2022-07-07 22:08 37 ******************
... ..( 4 skipped). .. ******************
104 2022-07-07 22:13 37 ******************
105 2022-07-07 22:14 38 *******************
... ..( 4 skipped). .. *******************
110 2022-07-07 22:19 38 *******************
111 2022-07-07 22:20 ? -
112 2022-07-07 22:21 27 ********
113 2022-07-07 22:22 28 *********
114 2022-07-07 22:23 29 **********
115 2022-07-07 22:24 30 ***********
116 2022-07-07 22:25 30 ***********
117 2022-07-07 22:26 31 ************
118 2022-07-07 22:27 31 ************
119 2022-07-07 22:28 32 *************
120 2022-07-07 22:29 32 *************
121 2022-07-07 22:30 32 *************
122 2022-07-07 22:31 33 **************
123 2022-07-07 22:32 33 **************
124 2022-07-07 22:33 33 **************
125 2022-07-07 22:34 34 ***************
126 2022-07-07 22:35 34 ***************
127 2022-07-07 22:36 34 ***************
0 2022-07-07 22:37 35 ****************
... ..( 13 skipped). .. ****************
14 2022-07-07 22:51 35 ****************
15 2022-07-07 22:52 36 *****************
16 2022-07-07 22:53 36 *****************
17 2022-07-07 22:54 35 ****************
18 2022-07-07 22:55 36 *****************
... ..( 26 skipped). .. *****************
45 2022-07-07 23:22 36 *****************
46 2022-07-07 23:23 37 ******************
47 2022-07-07 23:24 37 ******************
48 2022-07-07 23:25 36 *****************
... ..( 2 skipped). .. *****************
51 2022-07-07 23:28 36 *****************
52 2022-07-07 23:29 37 ******************
53 2022-07-07 23:30 36 *****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 57914 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS