Probe #72a69ce73a of MSI MS-7246 Desktop Computer
Log: smartctl
/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.14-desktop-1omv4002] (OpenMandriva Lx 7.2-2)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 9
Device Model: Maxtor 6Y160P0
Serial Number: --
Firmware Version: YAR41BW0
User Capacity: 163,928,604,672 bytes [163 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Fri Feb 19 16:04:04 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 302) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 72) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 203 202 063 - 17452
4 Start_Stop_Count -O--CK 252 252 000 - 2584
5 Reallocated_Sector_Ct PO--CK 253 253 063 - 7
6 Read_Channel_Margin P----- 253 253 100 - 0
7 Seek_Error_Rate -O-R-- 253 190 000 - 0
8 Seek_Time_Performance POS--K 244 235 187 - 33212
9 Power_On_Minutes -O--CK 139 139 000 - 397h+05m
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 247 247 000 - 2592
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 253 253 000 - 29
195 Hardware_ECC_Recovered -O-R-- 253 252 000 - 7938
196 Reallocated_Event_Count ---R-- 253 253 000 - 0
197 Current_Pending_Sector ---R-- 253 253 000 - 0
198 Offline_Uncorrectable ---R-- 253 253 000 - 0
199 UDMA_CRC_Error_Count ---R-- 199 199 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 252 000 - 95
202 Data_Address_Mark_Errs -O-R-- 253 252 000 - 0
203 Run_Out_Cancel PO-R-- 253 252 180 - 40
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
209 Offline_Seek_Performnce --S--K 191 189 000 - 0
99 Unknown_Attribute --S--- 253 253 000 - 0
100 Unknown_Attribute --S--- 253 253 000 - 0
101 Unknown_Attribute --S--- 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: scsi error badly formed scsi parameters
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 33161 -
# 2 Short offline Completed without error 00% 33160 -
# 3 Short offline Completed without error 00% 18326 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported