Probe #73ee7c16d5 of Dell Inspiron 5482
Log: smartctl
/dev/nvme0n1
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.14.5-300.fc42.x86_64] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KBG30ZMS256G NVMe TOSHIBA 256GB
Serial Number: --
Firmware Version: ADDA0103
PCI Vendor/Subsystem ID: 0x1179
IEEE OUI Identifier: 0x00080d
Controller ID: 0
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 00080d ...
Local Time is: Mon May 12 11:14:45 2025 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0017): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
Log Page Attributes (0x02): Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 82 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 3.30W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.30W - - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 8000 32000
4 - 0.0050W - - 4 4 4 4 8000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 - 4096 0 0
1 + 512 0 3
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning: 0x00
Temperature: 47 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 42%
Data Units Read: 82,405,689 [42.1 TB]
Data Units Written: 48,057,002 [24.6 TB]
Host Read Commands: 2,122,862,306
Host Write Commands: 818,615,973
Controller Busy Time: 13,961
Power Cycles: 2,716
Power On Hours: 10,359
Unsafe Shutdowns: 274
Media and Data Integrity Errors: 0
Error Information Log Entries: 19,755
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 47 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 19755 0 0x0012 0xc005 0x028 - 0 - Invalid Field in Command
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 7873 - - - - -
1 Short Aborted: Self-test command 7870 - - - - -
2 Short Aborted: Self-test command 7688 - - - - -
3 Short Aborted: Self-test command 7243 - - - - -
4 Short Aborted: Self-test command 7229 - - - - -
5 Short Completed without error 7004 - - - - -
6 Short Aborted: Self-test command 6990 - - - - -
7 Short Aborted: Self-test command 6990 - - - - -
8 Short Completed without error 6983 - - - - -
9 Short Aborted: Self-test command 6723 - - - - -
10 Short Completed without error 6722 - - - - -
11 Short Aborted: Self-test command 1654 - - - - -
12 Short Aborted: Self-test command 7 - - - - -