Probe #73ee7c16d5 of Dell Inspiron 5482

Log: smartctl

/dev/nvme0n1 smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.14.5-300.fc42.x86_64] (local build) Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: KBG30ZMS256G NVMe TOSHIBA 256GB Serial Number: -- Firmware Version: ADDA0103 PCI Vendor/Subsystem ID: 0x1179 IEEE OUI Identifier: 0x00080d Controller ID: 0 NVMe Version: 1.2 Number of Namespaces: 1 Namespace 1 Size/Capacity: 256,060,514,304 [256 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 00080d ... Local Time is: Mon May 12 11:14:45 2025 CEST Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x0017): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Log Page Attributes (0x02): Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 82 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 3.30W - - 0 0 0 0 0 0 1 + 2.70W - - 1 1 1 1 0 0 2 + 2.30W - - 2 2 2 2 0 0 3 - 0.0500W - - 3 3 3 3 8000 32000 4 - 0.0050W - - 4 4 4 4 8000 40000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 - 4096 0 0 1 + 512 0 3 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff) Critical Warning: 0x00 Temperature: 47 Celsius Available Spare: 100% Available Spare Threshold: 50% Percentage Used: 42% Data Units Read: 82,405,689 [42.1 TB] Data Units Written: 48,057,002 [24.6 TB] Host Read Commands: 2,122,862,306 Host Write Commands: 818,615,973 Controller Busy Time: 13,961 Power Cycles: 2,716 Power On Hours: 10,359 Unsafe Shutdowns: 274 Media and Data Integrity Errors: 0 Error Information Log Entries: 19,755 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 47 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message 0 19755 0 0x0012 0xc005 0x028 - 0 - Invalid Field in Command Self-test Log (NVMe Log 0x06, NSID 0xffffffff) Self-test status: No self-test in progress Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code 0 Short Completed without error 7873 - - - - - 1 Short Aborted: Self-test command 7870 - - - - - 2 Short Aborted: Self-test command 7688 - - - - - 3 Short Aborted: Self-test command 7243 - - - - - 4 Short Aborted: Self-test command 7229 - - - - - 5 Short Completed without error 7004 - - - - - 6 Short Aborted: Self-test command 6990 - - - - - 7 Short Aborted: Self-test command 6990 - - - - - 8 Short Completed without error 6983 - - - - - 9 Short Aborted: Self-test command 6723 - - - - - 10 Short Completed without error 6722 - - - - - 11 Short Aborted: Self-test command 1654 - - - - - 12 Short Aborted: Self-test command 7 - - - - -


Hardware for Linux and BSD

GitHub