/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-21-amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST750LM022 HN-M750MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2AR10002
User Capacity: 750,156,374,016 bytes [750 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Apr 23 10:29:38 2023 +03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 137) The previous self-test completed having
a test element that failed and the
device is suspected of having handling
damage.
Total time to complete Offline
data collection: ( 9660) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 161) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 001 001 051 NOW 312515
2 Throughput_Performance POS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 089 089 025 - 3456
4 Start_Stop_Count -O--CK 094 094 000 - 6929
5 Reallocated_Sector_Ct PO--CK 098 098 010 - 416
7 Seek_Error_Rate POSR-K 252 252 051 - 0
8 Seek_Time_Performance P-S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 33706
10 Spin_Retry_Count PO--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 099 099 000 - 1049
12 Power_Cycle_Count -O--CK 093 093 000 - 7197
181 Program_Fail_Cnt_Total -O---K 096 096 000 - 106753786
183 Runtime_Bad_Block -O--CK 100 100 010 - 4
184 End-to-End_Error PO--CK 252 252 048 - 0
186 Unknown_Attribute -O--CK 252 252 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 36278
188 Command_Timeout -O--CK 100 100 000 - 41
190 Airflow_Temperature_Cel -O---- 067 049 040 - 33 (Min/Max 9/52)
191 G-Sense_Error_Rate -O---K 100 100 000 - 348
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
193 Load_Cycle_Count -O--CK 083 083 000 - 181213
194 Temperature_Celsius -O---- 064 049 000 - 33 (Min/Max 9/52)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 098 098 000 - 416
197 Current_Pending_Sector -O--CK 080 079 000 - 3302
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 001 001 000 - 106046
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 36739 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 36739 [2] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 18 d6 c8 98 40 08 00:00:04.508 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.506 READ FPDMA QUEUED
60 00 00 00 20 00 00 19 5a d5 a0 40 08 00:00:04.506 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.506 READ FPDMA QUEUED
60 00 00 00 18 00 00 19 56 cf 00 40 08 00:00:04.506 READ FPDMA QUEUED
Error 36738 [1] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.497 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.499 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.499 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.499 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.499 READ FPDMA QUEUED
Error 36737 [0] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.491 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.493 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.493 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.493 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.493 READ FPDMA QUEUED
Error 36736 [7] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 10 01 00 00 00 39 47 bc 00 40 08 00:00:04.482 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.484 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.484 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.484 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.484 READ FPDMA QUEUED
Error 36735 [6] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.476 READ FPDMA QUEUED
60 00 10 01 00 00 00 39 47 bc 00 40 08 00:00:04.480 READ FPDMA QUEUED
60 00 10 01 00 00 00 3c ef b6 00 40 08 00:00:04.480 READ FPDMA QUEUED
60 00 10 01 00 00 00 3c ef b7 00 40 08 00:00:04.480 READ FPDMA QUEUED
60 00 10 00 c0 00 00 3c ef b4 40 40 08 00:00:04.480 READ FPDMA QUEUED
Error 36734 [5] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.475 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.478 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.478 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.478 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.478 READ FPDMA QUEUED
Error 36733 [4] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 10 01 00 00 00 39 47 bc 00 40 08 00:00:04.431 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.433 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.433 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.433 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.433 READ FPDMA QUEUED
Error 36732 [3] occurred at disk power-on lifetime: 33620 hours (1400 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 a0 00 00 39 47 bc 60 40 00
Error: UNC at LBA = 0x3947bc60 = 961002592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.426 READ FPDMA QUEUED
60 00 00 01 00 00 00 39 47 bc 00 40 08 00:00:04.429 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b6 00 40 08 00:00:04.429 READ FPDMA QUEUED
60 00 00 01 00 00 00 3c ef b7 00 40 08 00:00:04.429 READ FPDMA QUEUED
60 00 00 00 c0 00 00 3c ef b4 40 40 08 00:00:04.429 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: handling damage?? 90% 32827 0
# 2 Short offline Completed: handling damage?? 90% 32754 0
# 3 Short offline Completed: handling damage?? 90% 32753 0
# 4 Short offline Completed: handling damage?? 90% 32753 0
# 5 Extended offline Completed: handling damage?? 90% 29366 0
# 6 Extended offline Completed: handling damage?? 90% 29366 0
# 7 Short offline Completed: handling damage?? 90% 29366 0
# 8 Short offline Completed: handling damage?? 90% 29366 0
# 9 Short offline Completed: handling damage?? 90% 29366 0
#10 Extended offline Completed: handling damage?? 90% 29366 0
#11 Extended offline Completed: read failure 90% 29323 10008216
#12 Extended offline Completed: read failure 90% 29323 10008216
#13 Extended offline Interrupted (host reset) 90% 29312 -
#14 Extended offline Aborted by host 90% 29312 -
#15 Short offline Completed: read failure 90% 29311 669940416
#16 Short offline Completed: read failure 90% 29309 669940416
#17 Extended offline Aborted by host 90% 28367 -
#18 Short offline Completed: read failure 90% 28349 59872552
#19 Extended offline Aborted by host 90% 28349 -
#20 Extended offline Completed: read failure 90% 28280 59872552
#21 Short offline Completed without error 00% 25884 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_handling_damage?? [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 20/33 Celsius
Lifetime Min/Max Temperature: 9/52 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (84)
Index Estimated Time Temperature Celsius
85 2023-04-22 23:50 33 **************
86 2023-04-22 23:55 31 ************
... ..( 7 skipped). .. ************
94 2023-04-23 00:35 31 ************
95 2023-04-23 00:40 30 ***********
... ..( 43 skipped). .. ***********
11 2023-04-23 04:20 30 ***********
12 2023-04-23 04:25 29 **********
... ..( 26 skipped). .. **********
39 2023-04-23 06:40 29 **********
40 2023-04-23 06:45 30 ***********
... ..( 14 skipped). .. ***********
55 2023-04-23 08:00 30 ***********
56 2023-04-23 08:05 31 ************
57 2023-04-23 08:10 31 ************
58 2023-04-23 08:15 30 ***********
59 2023-04-23 08:20 31 ************
60 2023-04-23 08:25 31 ************
61 2023-04-23 08:30 30 ***********
... ..( 10 skipped). .. ***********
72 2023-04-23 09:25 30 ***********
73 2023-04-23 09:30 29 **********
... ..( 2 skipped). .. **********
76 2023-04-23 09:45 29 **********
77 2023-04-23 09:50 30 ***********
78 2023-04-23 09:55 31 ************
79 2023-04-23 10:00 31 ************
80 2023-04-23 10:05 31 ************
81 2023-04-23 10:10 32 *************
82 2023-04-23 10:15 32 *************
83 2023-04-23 10:20 33 **************
84 2023-04-23 10:25 33 **************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 26524 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific