/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST2000DM001-9YN164
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: CC4H
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jan 13 20:02:28 2019 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 592) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 227) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 116 093 006 - 111748656
3 Spin_Up_Time PO---- 094 094 000 - 0
4 Start_Stop_Count -O--CK 097 097 020 - 3198
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 081 060 030 - 4433678397
9 Power_On_Hours -O--CK 064 064 000 - 31649
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 2861
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 001 001 000 - 1166
188 Command_Timeout -O--CK 100 098 000 - 0 0 36
189 High_Fly_Writes -O-RCK 099 099 000 - 1
190 Airflow_Temperature_Cel -O---K 060 050 045 - 40 (Min/Max 24/44 #1)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 205
193 Load_Cycle_Count -O--CK 036 036 000 - 129606
194 Temperature_Celsius -O---K 040 050 000 - 40 (128 0 0 0 0)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 10771h+00m+01.817s
241 Total_LBAs_Written ------ 100 253 000 - 98446892251752
242 Total_LBAs_Read ------ 100 253 000 - 257241452677804
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 4496 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 5067 Device vendor specific log
0xbd GPL VS 512 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 1138 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1138 [17] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 94 b0 00 00
Error: UNC at LBA = 0x043794b0 = 70751408
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 94 70 e0 00 07:01:25.414 READ DMA EXT
25 00 00 01 00 00 00 04 37 93 70 e0 00 07:01:22.648 READ DMA EXT
25 00 00 01 00 00 00 04 37 92 70 e0 00 07:01:22.531 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 07:01:22.371 READ DMA EXT
25 00 00 00 20 00 00 04 37 93 e0 e0 00 07:01:19.650 READ DMA EXT
Error 1137 [16] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 93 f8 00 00
Error: UNC at LBA = 0x043793f8 = 70751224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 93 70 e0 00 07:01:22.648 READ DMA EXT
25 00 00 01 00 00 00 04 37 92 70 e0 00 07:01:22.531 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 07:01:22.371 READ DMA EXT
25 00 00 00 20 00 00 04 37 93 e0 e0 00 07:01:19.650 READ DMA EXT
35 00 00 00 20 00 00 29 4e 8b 20 e0 00 07:01:19.649 WRITE DMA EXT
Error 1136 [15] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 93 f8 00 00
Error: UNC at LBA = 0x043793f8 = 70751224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 04 37 93 e0 e0 00 07:01:19.650 READ DMA EXT
35 00 00 00 20 00 00 29 4e 8b 20 e0 00 07:01:19.649 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 c0 e0 00 07:01:19.649 READ DMA EXT
35 00 00 00 20 00 00 29 4e 8b 00 e0 00 07:01:19.649 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 a0 e0 00 07:01:19.648 READ DMA EXT
Error 1135 [14] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 94 b0 00 00
Error: UNC at LBA = 0x043794b0 = 70751408
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 94 70 e0 00 06:58:26.147 READ DMA EXT
25 00 00 01 00 00 00 04 37 92 70 e0 00 06:58:23.430 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 06:58:23.213 READ DMA EXT
35 00 00 00 08 00 00 00 6a 87 48 e0 00 06:58:23.213 WRITE DMA EXT
35 00 00 00 10 00 00 00 6f 77 70 e0 00 06:58:23.213 WRITE DMA EXT
Error 1134 [13] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 93 f8 00 00
Error: UNC at LBA = 0x043793f8 = 70751224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 92 70 e0 00 06:58:23.430 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 06:58:23.213 READ DMA EXT
35 00 00 00 08 00 00 00 6a 87 48 e0 00 06:58:23.213 WRITE DMA EXT
35 00 00 00 10 00 00 00 6f 77 70 e0 00 06:58:23.213 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 e0 e0 00 06:58:20.496 READ DMA EXT
Error 1133 [12] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 93 f8 00 00
Error: UNC at LBA = 0x043793f8 = 70751224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 04 37 93 e0 e0 00 06:58:20.496 READ DMA EXT
35 00 00 00 20 00 00 29 4f 8a 80 e0 00 06:58:20.496 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 c0 e0 00 06:58:20.495 READ DMA EXT
35 00 00 00 20 00 00 29 4f 8a 60 e0 00 06:58:20.495 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 a0 e0 00 06:58:20.495 READ DMA EXT
Error 1132 [11] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 94 b0 00 00
Error: UNC at LBA = 0x043794b0 = 70751408
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 94 70 e0 00 06:52:21.155 READ DMA EXT
25 00 00 01 00 00 00 04 37 92 70 e0 00 06:52:18.438 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 06:52:18.204 READ DMA EXT
25 00 00 00 20 00 00 04 37 93 e0 e0 00 06:52:15.488 READ DMA EXT
35 00 00 00 20 00 00 29 5b 0e a0 e0 00 06:52:15.487 WRITE DMA EXT
Error 1131 [10] occurred at disk power-on lifetime: 14635 hours (609 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 04 37 93 f8 00 00
Error: UNC at LBA = 0x043793f8 = 70751224
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 04 37 92 70 e0 00 06:52:18.438 READ DMA EXT
25 00 00 01 00 00 00 04 37 91 70 e0 00 06:52:18.204 READ DMA EXT
25 00 00 00 20 00 00 04 37 93 e0 e0 00 06:52:15.488 READ DMA EXT
35 00 00 00 20 00 00 29 5b 0e a0 e0 00 06:52:15.487 WRITE DMA EXT
25 00 00 00 20 00 00 04 37 93 c0 e0 00 06:52:15.487 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 31625 -
# 2 Extended offline Interrupted (host reset) 00% 31562 -
# 3 Extended offline Interrupted (host reset) 00% 31473 -
# 4 Extended offline Interrupted (host reset) 00% 31425 -
# 5 Extended offline Interrupted (host reset) 00% 31369 -
# 6 Extended offline Interrupted (host reset) 00% 31295 -
# 7 Extended offline Completed without error 00% 31258 -
# 8 Extended offline Interrupted (host reset) 00% 31248 -
# 9 Extended offline Completed without error 00% 31189 -
#10 Extended offline Interrupted (host reset) 00% 31146 -
#11 Extended offline Interrupted (host reset) 00% 31086 -
#12 Extended offline Completed without error 00% 31033 -
#13 Extended offline Completed without error 00% 31002 -
#14 Extended offline Completed without error 00% 30964 -
#15 Extended offline Completed without error 00% 30935 -
#16 Extended offline Completed without error 00% 30883 -
#17 Extended offline Completed without error 00% 30808 -
#18 Extended offline Interrupted (host reset) 00% 30757 -
#19 Extended offline Completed without error 00% 30738 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 24/44 Celsius
Lifetime Min/Max Temperature: 13/49 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 40 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3250310AS
Serial Number: --
Firmware Version: 3.AAF
User Capacity: 250,058,268,160 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sun Jan 13 20:02:28 2019 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0
3 Spin_Up_Time PO---- 098 097 000 - 0
4 Start_Stop_Count -O--CK 094 094 020 - 6547
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 11
7 Seek_Error_Rate POSR-- 084 060 030 - 326164862
9 Power_On_Hours -O--CK 083 083 000 - 15754
10 Spin_Retry_Count PO--C- 100 099 097 - 0
12 Power_Cycle_Count -O--CK 094 094 020 - 7098
187 Reported_Uncorrect -O--CK 064 064 000 - 36
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 060 045 045 Past 40 (Min/Max 13/55)
194 Temperature_Celsius -O---K 040 055 000 - 40 (0 13 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 059 053 000 - 27049968
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 152 000 - 2060
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 37 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 37 [16] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6c 00 5e f3 e0 00
Error: UNC at LBA = 0x6c005ef3 = 1811963635
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 80 00 00 6c 00 5e df e0 00 00:03:50.550 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 87 e0 00 00:03:50.540 READ DMA EXT
25 00 00 00 30 00 00 6c 00 5e a7 e0 00 00:03:50.516 READ DMA EXT
25 00 00 00 80 00 00 6c 00 5e 27 e0 00 00:03:46.500 READ DMA EXT
25 00 00 00 80 00 00 6b 00 5e a7 e0 00 00:03:46.500 READ DMA EXT
Error 36 [15] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6d 00 5e 0c e0 00
Error: UNC at LBA = 0x6d005e0c = 1828740620
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 6d 00 5e 07 e0 00 00:03:58.374 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:58.350 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e ff e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e f7 e0 00 00:03:54.492 READ DMA EXT
Error 35 [14] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6d 00 5e 0c e0 00
Error: UNC at LBA = 0x6d005e0c = 1828740620
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 80 00 00 6c 00 5e f7 e0 00 00:03:58.374 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:58.350 READ DMA EXT
25 00 00 00 10 00 00 6c 00 5e df e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:54.492 READ DMA EXT
35 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:54.492 WRITE DMA EXT
Error 34 [13] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6c 00 5e f3 e0 00
Error: UNC at LBA = 0x6c005ef3 = 1811963635
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 6c 00 5e ef e0 00 00:03:50.550 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e e7 e0 00 00:03:50.540 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e df e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
Error 33 [12] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6c 00 5e f3 e0 00
Error: UNC at LBA = 0x6c005ef3 = 1811963635
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 80 00 00 6c 00 5e df e0 00 00:03:50.550 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 87 e0 00 00:03:50.540 READ DMA EXT
25 00 00 00 30 00 00 6c 00 5e a7 e0 00 00:03:50.516 READ DMA EXT
25 00 00 00 80 00 00 6c 00 5e 27 e0 00 00:03:46.500 READ DMA EXT
25 00 00 00 80 00 00 6b 00 5e a7 e0 00 00:03:46.500 READ DMA EXT
Error 32 [11] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6d 00 5e 0c e0 00
Error: UNC at LBA = 0x6d005e0c = 1828740620
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 6d 00 5e 07 e0 00 00:03:58.374 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:58.350 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e ff e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e f7 e0 00 00:03:54.492 READ DMA EXT
Error 31 [10] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6d 00 5e 0c e0 00
Error: UNC at LBA = 0x6d005e0c = 1828740620
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 80 00 00 6c 00 5e f7 e0 00 00:03:58.374 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:58.350 READ DMA EXT
25 00 00 00 10 00 00 6c 00 5e df e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:54.492 READ DMA EXT
35 00 00 00 08 00 00 f4 00 63 8f e0 00 00:03:54.492 WRITE DMA EXT
Error 30 [9] occurred at disk power-on lifetime: 4569 hours (190 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 6c 00 5e f3 e0 00
Error: UNC at LBA = 0x6c005ef3 = 1811963635
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 08 00 00 6c 00 5e ef e0 00 00:03:50.550 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e e7 e0 00 00:03:50.540 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 08 00 00 6c 00 5e df e0 00 00:03:54.492 READ DMA EXT
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:03:54.492 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 15747 -
# 2 Extended offline Completed without error 00% 15728 -
# 3 Extended offline Aborted by host 40% 15666 -
# 4 Extended offline Aborted by host 80% 15577 -
# 5 Extended offline Completed without error 00% 15527 -
# 6 Extended offline Aborted by host 80% 15470 -
# 7 Extended offline Completed without error 00% 15396 -
# 8 Extended offline Completed without error 00% 15355 -
# 9 Extended offline Aborted by host 50% 15347 -
#10 Extended offline Completed without error 00% 15286 -
#11 Extended offline Aborted by host 60% 15244 -
#12 Extended offline Completed without error 00% 15181 -
#13 Extended offline Interrupted (host reset) 30% 15127 -
#14 Extended offline Completed without error 00% 15094 -
#15 Extended offline Completed without error 00% 15055 -
#16 Extended offline Completed without error 00% 15026 -
#17 Extended offline Completed without error 00% 14973 -
#18 Extended offline Completed without error 00% 14897 -
#19 Extended offline Aborted by host 30% 14848 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 521 (0x0209)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Max Temperature: 0 Celsius
Lifetime Max Temperature: 0 Celsius
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 41 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 41 Transition from drive PhyRdy to drive PhyNRdy
0x8002 2 0 Vendor specific
0x8003 2 10 Vendor specific
0x8004 2 0 Vendor specific
/dev/sdc
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST3160827AS
Serial Number: --
Firmware Version: 3.42
User Capacity: 160,040,803,840 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Sun Jan 13 20:02:29 2019 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 94) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 055 048 006 - 4872820
3 Spin_Up_Time PO---- 096 096 000 - 0
4 Start_Stop_Count -O--CK 087 087 020 - 13399
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 089 060 030 - 899488029
9 Power_On_Hours -O--CK 079 079 000 - 18808
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 090 090 020 - 11197
194 Temperature_Celsius -O---K 039 057 000 - 39 (0 6 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 055 048 000 - 4872820
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 001 000 - 3232
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x20 SL R/O 1 Streaming performance log [OBS-8]
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 1176 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1176 occurred at disk power-on lifetime: 9248 hours (385 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 6f 50 ed f0 e0
Error: ICRC, ABRT 111 sectors at LBA = 0x00f0ed50 = 15789392
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 80 3f ed f0 e0 00 00:04:14.846 READ DMA EXT
25 03 80 bf ec f0 e0 00 00:04:14.826 READ DMA EXT
25 03 80 3f ec f0 e0 00 00:04:14.807 READ DMA EXT
25 03 80 bf eb f0 e0 00 00:04:14.805 READ DMA EXT
25 03 80 bf eb f0 e0 00 00:04:14.785 READ DMA EXT
Error 1175 occurred at disk power-on lifetime: 9248 hours (385 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 3f 00 ec f0 e0
Error: ICRC, ABRT 63 sectors at LBA = 0x00f0ec00 = 15789056
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 80 bf eb f0 e0 00 00:04:14.846 READ DMA EXT
25 03 80 3f eb f0 e0 00 00:04:14.826 READ DMA EXT
25 03 80 bf ea f0 e0 00 00:04:14.807 READ DMA EXT
25 03 80 3f ea f0 e0 00 00:04:14.805 READ DMA EXT
25 03 80 bf e9 f0 e0 00 00:04:14.785 READ DMA EXT
Error 1174 occurred at disk power-on lifetime: 9248 hours (385 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 2f c8 ef bc e0
Error: ICRC, ABRT 47 sectors at LBA = 0x00bcefc8 = 12382152
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 80 77 ef bc e0 00 00:04:03.708 READ DMA EXT
25 03 80 f7 ee bc e0 00 00:04:03.706 READ DMA EXT
25 03 80 77 ee bc e0 00 00:04:03.704 READ DMA EXT
25 03 80 f7 ed bc e0 00 00:04:03.702 READ DMA EXT
25 03 80 77 ed bc e0 00 00:04:03.700 READ DMA EXT
Error 1173 occurred at disk power-on lifetime: 9240 hours (385 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 0f 00 5a b8 e0
Error: ICRC, ABRT 15 sectors at LBA = 0x00b85a00 = 12081664
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 80 8f 59 b8 e0 00 00:39:01.405 READ DMA EXT
25 03 08 87 58 b8 e0 00 00:39:01.399 READ DMA EXT
25 03 08 7f 58 b8 e0 00 00:39:01.382 READ DMA EXT
25 03 08 77 58 b8 e0 00 00:39:00.609 READ DMA EXT
25 03 08 6f 58 b8 e0 00 00:39:00.077 READ DMA EXT
Error 1172 occurred at disk power-on lifetime: 9073 hours (378 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 26 a6 50 e0
Error: ICRC, ABRT at LBA = 0x0050a626 = 5285414
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 08 1f a6 50 e0 00 00:00:46.135 READ DMA EXT
25 03 08 1f a6 50 e0 00 00:01:05.023 READ DMA EXT
25 03 08 3f 00 60 e0 00 00:01:03.382 READ DMA EXT
25 03 08 3f 00 60 e0 00 00:01:03.370 READ DMA EXT
25 03 08 3f 00 00 e0 00 00:01:01.723 READ DMA EXT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 18782 -
# 2 Extended offline Aborted by host 40% 18720 -
# 3 Extended offline Aborted by host 80% 18633 -
# 4 Extended offline Completed without error 00% 18584 -
# 5 Extended offline Aborted by host 80% 18528 -
# 6 Extended offline Aborted by host 30% 18454 -
# 7 Extended offline Completed without error 00% 18415 -
# 8 Extended offline Aborted by host 60% 18407 -
# 9 Extended offline Completed without error 00% 18346 -
#10 Extended offline Aborted by host 60% 18305 -
#11 Extended offline Completed without error 00% 18243 -
#12 Extended offline Completed without error 00% 18190 -
#13 Extended offline Completed without error 00% 18158 -
#14 Extended offline Completed without error 00% 18119 -
#15 Extended offline Completed without error 00% 18090 -
#16 Extended offline Completed without error 00% 18038 -
#17 Extended offline Completed without error 00% 17963 -
#18 Extended offline Aborted by host 40% 17915 -
#19 Extended offline Completed without error 00% 17894 -
#20 Extended offline Completed without error 00% 17846 -
#21 Extended offline Aborted by host 60% 17793 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported