Probe #8ff57cadde of Lenovo ThinkPad X230 2324A1...
Log: smartctl
/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.74-generic-2rosa2021.1-x86_64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD1600BEVS-08VAT2
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 14.01A14
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 1.5 Gb/s
Local Time is: Tue Apr 19 12:02:32 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 59) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 160 155 021 - 991
4 Start_Stop_Count -O--CK 081 081 000 - 19975
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 090 090 000 - 7711
10 Spin_Retry_Count PO--CK 100 099 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 094 094 000 - 6031
192 Power-Off_Retract_Count -O--CK 200 200 000 - 491
193 Load_Cycle_Count -O--CK 105 105 000 - 285228
194 Temperature_Celsius -O---K 111 088 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
240 Head_Flying_Hours -O--CK 096 096 000 - 2989
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 6696 -
# 2 Short offline Completed without error 00% 6685 -
# 3 Short offline Completed without error 00% 6673 -
# 4 Short offline Completed without error 00% 6667 -
# 5 Short offline Completed without error 00% 6651 -
# 6 Short offline Completed without error 00% 6637 -
# 7 Short offline Completed without error 00% 6629 -
# 8 Extended offline Completed without error 00% 6627 -
# 9 Short offline Completed without error 00% 6616 -
#10 Short offline Completed without error 00% 6611 -
#11 Vendor (0x50) Aborted by host 10% 6538 -
#12 Short offline Aborted by host 10% 6538 -
#13 Vendor (0x50) Completed without error 00% 6524 -
#14 Short offline Completed without error 00% 6523 -
#15 Vendor (0x50) Aborted by host 90% 6520 -
#16 Short offline Aborted by host 10% 6520 -
#17 Vendor (0x50) Aborted by host 90% 6519 -
#18 Short offline Aborted by host 10% 6519 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 18/33 Celsius
Lifetime Min/Max Temperature: 19/55 Celsius
Specified Max Operating Temperature: 25 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 1/85 Celsius
Temperature History Size (Index): 128 (38)
Index Estimated Time Temperature Celsius
39 2022-04-19 09:55 32 *************
... ..( 36 skipped). .. *************
76 2022-04-19 10:32 32 *************
77 2022-04-19 10:33 31 ************
78 2022-04-19 10:34 31 ************
79 2022-04-19 10:35 32 *************
80 2022-04-19 10:36 32 *************
81 2022-04-19 10:37 32 *************
82 2022-04-19 10:38 31 ************
... ..( 13 skipped). .. ************
96 2022-04-19 10:52 31 ************
97 2022-04-19 10:53 32 *************
... ..( 41 skipped). .. *************
11 2022-04-19 11:35 32 *************
12 2022-04-19 11:36 33 **************
13 2022-04-19 11:37 33 **************
14 2022-04-19 11:38 32 *************
... ..( 23 skipped). .. *************
38 2022-04-19 12:02 32 *************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x8000 4 18362 Vendor specific