Probe #8ff57cadde of Lenovo ThinkPad X230 2324A1...

Log: smartctl

/dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.74-generic-2rosa2021.1-x86_64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA Device Model: WDC WD1600BEVS-08VAT2 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 14.01A14 User Capacity: 160,041,885,696 bytes [160 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 1.5 Gb/s Local Time is: Tue Apr 19 12:02:32 2022 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 4800) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 59) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 160 155 021 - 991 4 Start_Stop_Count -O--CK 081 081 000 - 19975 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate POSR-K 200 200 051 - 0 9 Power_On_Hours -O--CK 090 090 000 - 7711 10 Spin_Retry_Count PO--CK 100 099 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 094 094 000 - 6031 192 Power-Off_Retract_Count -O--CK 200 200 000 - 491 193 Load_Cycle_Count -O--CK 105 105 000 - 285228 194 Temperature_Celsius -O---K 111 088 000 - 32 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0 240 Head_Flying_Hours -O--CK 096 096 000 - 2989 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 6696 - # 2 Short offline Completed without error 00% 6685 - # 3 Short offline Completed without error 00% 6673 - # 4 Short offline Completed without error 00% 6667 - # 5 Short offline Completed without error 00% 6651 - # 6 Short offline Completed without error 00% 6637 - # 7 Short offline Completed without error 00% 6629 - # 8 Extended offline Completed without error 00% 6627 - # 9 Short offline Completed without error 00% 6616 - #10 Short offline Completed without error 00% 6611 - #11 Vendor (0x50) Aborted by host 10% 6538 - #12 Short offline Aborted by host 10% 6538 - #13 Vendor (0x50) Completed without error 00% 6524 - #14 Short offline Completed without error 00% 6523 - #15 Vendor (0x50) Aborted by host 90% 6520 - #16 Short offline Aborted by host 10% 6520 - #17 Vendor (0x50) Aborted by host 90% 6519 - #18 Short offline Aborted by host 10% 6519 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 32 Celsius Power Cycle Min/Max Temperature: 18/33 Celsius Lifetime Min/Max Temperature: 19/55 Celsius Specified Max Operating Temperature: 25 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: 1/85 Celsius Temperature History Size (Index): 128 (38) Index Estimated Time Temperature Celsius 39 2022-04-19 09:55 32 ************* ... ..( 36 skipped). .. ************* 76 2022-04-19 10:32 32 ************* 77 2022-04-19 10:33 31 ************ 78 2022-04-19 10:34 31 ************ 79 2022-04-19 10:35 32 ************* 80 2022-04-19 10:36 32 ************* 81 2022-04-19 10:37 32 ************* 82 2022-04-19 10:38 31 ************ ... ..( 13 skipped). .. ************ 96 2022-04-19 10:52 31 ************ 97 2022-04-19 10:53 32 ************* ... ..( 41 skipped). .. ************* 11 2022-04-19 11:35 32 ************* 12 2022-04-19 11:36 33 ************** 13 2022-04-19 11:37 33 ************** 14 2022-04-19 11:38 32 ************* ... ..( 23 skipped). .. ************* 38 2022-04-19 12:02 32 ************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 10 Device-to-host register FISes sent due to a COMRESET 0x8000 4 18362 Vendor specific


Hardware for Linux and BSD

GitHub