/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: OCZ-AGILITY3
Serial Number: --
LU WWN Device Id: 5 e83a97 ...
Firmware Version: 2.25
User Capacity: 60 022 480 896 bytes [60,0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jan 6 17:32:43 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 098 098 000 - 2530h+23m+38.250s
12 Power_Cycle_Count -O--CK 100 100 000 - 994
171 Program_Fail_Count -O--CK 000 000 000 - 0
172 Erase_Fail_Count -O--CK 000 000 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 109
177 Wear_Range_Delta ------ 000 000 000 - 1
181 Program_Fail_Count -O--CK 000 000 000 - 0
182 Erase_Fail_Count -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 100 100 010 - 0
233 SandForce_Internal ------ 000 000 000 - 1728
234 SandForce_Internal -O--CK 000 000 000 - 1535
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 1535
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 1981
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/30 Celsius
Lifetime Min/Max Temperature: 30/30 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 0 minutes
Temperature Logging Interval: 0 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 478 (1)
Index Estimated Time Temperature Celsius
2 2017-01-06 09:35 ? -
... ..(476 skipped). .. -
1 2017-01-06 17:32 ? -
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue
Device Model: WDC WD5000AAKX-60U6AA0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 18.01H18
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jan 6 17:32:43 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 8460) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 86) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 392
3 Spin_Up_Time POS--K 143 142 021 - 3825
4 Start_Stop_Count -O--CK 100 100 000 - 978
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 091 091 000 - 6676
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 904
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 001 000 - 257
188 Command_Timeout -O--CK 100 074 000 - 26
190 Airflow_Temperature_Cel -O---K 064 052 040 - 36 (Min/Max 27/36)
192 Power-Off_Retract_Count -O--CK 200 200 000 - 63
193 Load_Cycle_Count -O--CK 200 200 000 - 914
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 1
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 257 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 257 [16] occurred at disk power-on lifetime: 6340 hours (264 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 01 38 a5 09 e0 00
Error: UNC 2 sectors at LBA = 0x0138a509 = 20489481
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 02 00 00 01 38 a5 09 e0 00 01:06:50.715 READ DMA EXT
25 00 00 00 02 00 00 01 38 a5 07 e0 00 01:06:50.715 READ DMA EXT
25 00 00 00 02 00 00 01 38 a5 05 e0 00 01:06:50.714 READ DMA EXT
25 00 00 00 02 00 00 01 38 a5 03 e0 00 01:06:50.714 READ DMA EXT
25 00 00 00 02 00 00 01 38 a5 01 e0 00 01:06:50.714 READ DMA EXT
Error 256 [15] occurred at disk power-on lifetime: 6340 hours (264 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 01 38 9c 86 e0 00
Error: UNC 2 sectors at LBA = 0x01389c86 = 20487302
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 02 00 00 01 38 9c 85 e0 00 01:04:30.960 READ DMA EXT
25 00 00 00 02 00 00 01 38 aa 69 e0 00 01:04:30.959 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 81 e0 00 01:04:30.959 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 7d e0 00 01:04:30.959 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 79 e0 00 01:04:30.959 READ DMA EXT
Error 255 [14] occurred at disk power-on lifetime: 6340 hours (264 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c 86 e0 00
Error: UNC 256 sectors at LBA = 0x01389c86 = 20487302
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 1f e0 00 00:47:12.815 READ DMA EXT
25 00 00 01 00 00 00 01 38 9b 1f e0 00 00:47:12.814 READ DMA EXT
25 00 00 01 00 00 00 01 38 9a 1f e0 00 00:47:12.814 READ DMA EXT
25 00 00 01 00 00 00 01 38 99 1f e0 00 00:47:12.813 READ DMA EXT
25 00 00 01 00 00 00 01 38 98 1f e0 00 00:47:12.813 READ DMA EXT
Error 254 [13] occurred at disk power-on lifetime: 6339 hours (264 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c 86 e0 00
Error: UNC 256 sectors at LBA = 0x01389c86 = 20487302
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:26:40.318 READ DMA EXT
25 00 00 00 48 00 00 00 3d 7e af e0 00 00:26:40.305 READ DMA EXT
25 00 00 00 50 00 00 00 df 53 f7 e0 00 00:26:40.297 READ DMA EXT
25 00 00 00 68 00 00 00 18 9b 3f e0 00 00:26:40.281 READ DMA EXT
25 00 00 00 68 00 00 06 75 82 77 e0 00 00:26:40.280 READ DMA EXT
Error 253 [12] occurred at disk power-on lifetime: 6339 hours (264 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c 86 e0 00
Error: UNC 256 sectors at LBA = 0x01389c86 = 20487302
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:20:34.194 READ DMA EXT
25 00 00 00 18 00 00 00 b4 63 e7 e0 00 00:20:34.193 READ DMA EXT
25 00 00 00 80 00 00 00 b4 63 67 e0 00 00:20:34.192 READ DMA EXT
25 00 00 00 80 00 00 00 b4 62 e7 e0 00 00:20:34.187 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 3f e0 00 00:20:34.186 READ DMA EXT
Error 252 [11] occurred at disk power-on lifetime: 6339 hours (264 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c 86 e0 00
Error: UNC 256 sectors at LBA = 0x01389c86 = 20487302
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:20:32.296 READ DMA EXT
25 00 00 00 50 00 00 00 40 89 b7 e0 00 00:20:32.285 READ DMA EXT
25 00 00 00 28 00 00 06 83 a5 47 e0 00 00:20:32.284 READ DMA EXT
25 00 00 00 80 00 00 06 83 a4 c7 e0 00 00:20:32.284 READ DMA EXT
25 00 00 00 80 00 00 06 83 a4 47 e0 00 00:20:32.283 READ DMA EXT
Error 251 [10] occurred at disk power-on lifetime: 6339 hours (264 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c c9 e0 00
Error: UNC 256 sectors at LBA = 0x01389cc9 = 20487369
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:19:36.030 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 45 e0 00 00:19:36.029 READ DMA EXT
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:19:33.299 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 43 e0 00 00:19:33.298 READ DMA EXT
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:19:31.261 READ DMA EXT
Error 250 [9] occurred at disk power-on lifetime: 6339 hours (264 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 01 38 9c ff e0 00
Error: UNC 256 sectors at LBA = 0x01389cff = 20487423
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:19:33.299 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 43 e0 00 00:19:33.298 READ DMA EXT
25 00 00 01 00 00 00 01 38 9c 3f e0 00 00:19:31.261 READ DMA EXT
25 00 00 00 02 00 00 01 38 9c 41 e0 00 00:19:31.260 READ DMA EXT
35 00 00 00 02 00 00 01 38 9c 41 e0 00 00:19:31.259 WRITE DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 27/36 Celsius
Lifetime Min/Max Temperature: 0/48 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (113)
Index Estimated Time Temperature Celsius
114 2017-01-06 15:25 37 ******************
115 2017-01-06 15:26 38 *******************
116 2017-01-06 15:27 37 ******************
117 2017-01-06 15:28 37 ******************
118 2017-01-06 15:29 37 ******************
119 2017-01-06 15:30 38 *******************
... ..( 42 skipped). .. *******************
34 2017-01-06 16:13 38 *******************
35 2017-01-06 16:14 39 ********************
36 2017-01-06 16:15 38 *******************
37 2017-01-06 16:16 38 *******************
38 2017-01-06 16:17 38 *******************
39 2017-01-06 16:18 39 ********************
40 2017-01-06 16:19 38 *******************
... ..( 43 skipped). .. *******************
84 2017-01-06 17:03 38 *******************
85 2017-01-06 17:04 ? -
86 2017-01-06 17:05 27 ********
87 2017-01-06 17:06 27 ********
88 2017-01-06 17:07 27 ********
89 2017-01-06 17:08 28 *********
90 2017-01-06 17:09 29 **********
91 2017-01-06 17:10 29 **********
92 2017-01-06 17:11 30 ***********
93 2017-01-06 17:12 30 ***********
94 2017-01-06 17:13 31 ************
95 2017-01-06 17:14 32 *************
96 2017-01-06 17:15 32 *************
97 2017-01-06 17:16 32 *************
98 2017-01-06 17:17 33 **************
99 2017-01-06 17:18 33 **************
100 2017-01-06 17:19 34 ***************
101 2017-01-06 17:20 34 ***************
102 2017-01-06 17:21 34 ***************
103 2017-01-06 17:22 35 ****************
... ..( 7 skipped). .. ****************
111 2017-01-06 17:30 35 ****************
112 2017-01-06 17:31 36 *****************
113 2017-01-06 17:32 36 *****************
SCT Error Recovery Control:
Read: 85 (8,5 seconds)
Write: 85 (8,5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1853 Vendor specific
/dev/sdc
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Green
Device Model: WDC WD5000AADS-00S9B0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.00A01
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Jan 6 17:32:43 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10200) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 120) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 42
3 Spin_Up_Time POS--K 150 146 021 - 3491
4 Start_Stop_Count -O--CK 097 097 000 - 3717
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 090 090 000 - 7576
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2861
192 Power-Off_Retract_Count -O--CK 200 200 000 - 606
193 Load_Cycle_Count -O--CK 166 166 000 - 104996
194 Temperature_Celsius -O---K 113 094 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 529 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 529 [0] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:13:39.969 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:13:39.969 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:13:39.969 IDENTIFY DEVICE
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:12:32.489 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:12:32.488 SMART WRITE LOG
Error 528 [23] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:13:39.969 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:13:39.969 IDENTIFY DEVICE
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:12:32.489 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:12:32.488 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:12:32.488 IDENTIFY DEVICE
Error 527 [22] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:12:32.489 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:12:32.488 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:12:32.488 IDENTIFY DEVICE
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:11:03.768 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:11:03.768 SMART WRITE LOG
Error 526 [21] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:12:32.488 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:12:32.488 IDENTIFY DEVICE
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:11:03.768 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:11:03.768 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:11:03.767 IDENTIFY DEVICE
Error 525 [20] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 04:11:03.768 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:11:03.768 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:11:03.767 IDENTIFY DEVICE
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:10:30.970 SMART WRITE LOG
60 00 08 00 00 00 00 0c 95 08 00 40 08 04:09:58.229 READ FPDMA QUEUED
Error 524 [19] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:11:03.768 SMART WRITE LOG
ec 00 00 00 01 00 00 00 00 00 00 00 08 04:11:03.767 IDENTIFY DEVICE
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:10:30.970 SMART WRITE LOG
60 00 08 00 00 00 00 0c 95 08 00 40 08 04:09:58.229 READ FPDMA QUEUED
60 00 08 00 00 00 00 0c 35 08 80 40 08 04:09:58.229 READ FPDMA QUEUED
Error 523 [18] occurred at disk power-on lifetime: 5143 hours (214 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 04:10:30.970 SMART WRITE LOG
60 00 08 00 00 00 00 0c 95 08 00 40 08 04:09:58.229 READ FPDMA QUEUED
60 00 08 00 00 00 00 0c 35 08 80 40 08 04:09:58.229 READ FPDMA QUEUED
60 00 08 00 00 00 00 0c 35 08 00 40 08 04:09:58.228 READ FPDMA QUEUED
60 00 08 00 00 00 00 00 60 08 00 40 08 04:09:58.225 READ FPDMA QUEUED
Error 522 [17] occurred at disk power-on lifetime: 4029 hours (167 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 00 63 2b 79 40 00
Error: WP at LBA = 0x00632b79 = 6499193
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 10 00 00 00 62 b4 50 40 00 00:10:41.803 WRITE FPDMA QUEUED
61 00 08 00 10 00 00 00 60 6e c0 40 00 00:10:41.802 WRITE FPDMA QUEUED
60 00 20 00 08 00 00 00 63 2b 60 40 00 00:10:41.802 READ FPDMA QUEUED
ef 00 02 00 00 00 00 00 00 00 00 00 00 00:10:41.802 SET FEATURES [Enable write cache]
60 00 20 00 30 00 00 00 63 2b 60 40 00 00:10:38.969 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 27/30 Celsius
Lifetime Min/Max Temperature: 27/49 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (175)
Index Estimated Time Temperature Celsius
176 2017-01-06 09:35 32 *************
... ..( 38 skipped). .. *************
215 2017-01-06 10:14 32 *************
216 2017-01-06 10:15 ? -
217 2017-01-06 10:16 32 *************
... ..( 17 skipped). .. *************
235 2017-01-06 10:34 32 *************
236 2017-01-06 10:35 31 ************
... ..( 6 skipped). .. ************
243 2017-01-06 10:42 31 ************
244 2017-01-06 10:43 32 *************
245 2017-01-06 10:44 32 *************
246 2017-01-06 10:45 32 *************
247 2017-01-06 10:46 31 ************
... ..( 5 skipped). .. ************
253 2017-01-06 10:52 31 ************
254 2017-01-06 10:53 30 ***********
... ..( 18 skipped). .. ***********
273 2017-01-06 11:12 30 ***********
274 2017-01-06 11:13 ? -
275 2017-01-06 11:14 30 ***********
276 2017-01-06 11:15 ? -
277 2017-01-06 11:16 23 ****
... ..( 3 skipped). .. ****
281 2017-01-06 11:20 23 ****
282 2017-01-06 11:21 24 *****
283 2017-01-06 11:22 25 ******
... ..( 3 skipped). .. ******
287 2017-01-06 11:26 25 ******
288 2017-01-06 11:27 26 *******
... ..( 3 skipped). .. *******
292 2017-01-06 11:31 26 *******
293 2017-01-06 11:32 27 ********
294 2017-01-06 11:33 28 *********
295 2017-01-06 11:34 29 **********
296 2017-01-06 11:35 29 **********
297 2017-01-06 11:36 29 **********
298 2017-01-06 11:37 30 ***********
299 2017-01-06 11:38 30 ***********
300 2017-01-06 11:39 31 ************
301 2017-01-06 11:40 31 ************
302 2017-01-06 11:41 32 *************
303 2017-01-06 11:42 33 **************
304 2017-01-06 11:43 32 *************
305 2017-01-06 11:44 32 *************
306 2017-01-06 11:45 31 ************
307 2017-01-06 11:46 31 ************
308 2017-01-06 11:47 30 ***********
... ..( 6 skipped). .. ***********
315 2017-01-06 11:54 30 ***********
316 2017-01-06 11:55 29 **********
... ..( 5 skipped). .. **********
322 2017-01-06 12:01 29 **********
323 2017-01-06 12:02 ? -
324 2017-01-06 12:03 28 *********
325 2017-01-06 12:04 ? -
326 2017-01-06 12:05 22 ***
327 2017-01-06 12:06 22 ***
328 2017-01-06 12:07 23 ****
329 2017-01-06 12:08 23 ****
330 2017-01-06 12:09 24 *****
331 2017-01-06 12:10 25 ******
332 2017-01-06 12:11 25 ******
333 2017-01-06 12:12 26 *******
334 2017-01-06 12:13 26 *******
335 2017-01-06 12:14 27 ********
336 2017-01-06 12:15 27 ********
337 2017-01-06 12:16 28 *********
338 2017-01-06 12:17 29 **********
... ..( 3 skipped). .. **********
342 2017-01-06 12:21 29 **********
343 2017-01-06 12:22 30 ***********
344 2017-01-06 12:23 30 ***********
345 2017-01-06 12:24 ? -
346 2017-01-06 12:25 22 ***
347 2017-01-06 12:26 22 ***
348 2017-01-06 12:27 22 ***
349 2017-01-06 12:28 23 ****
350 2017-01-06 12:29 24 *****
351 2017-01-06 12:30 25 ******
352 2017-01-06 12:31 25 ******
353 2017-01-06 12:32 26 *******
... ..( 2 skipped). .. *******
356 2017-01-06 12:35 26 *******
357 2017-01-06 12:36 27 ********
358 2017-01-06 12:37 28 *********
359 2017-01-06 12:38 28 *********
360 2017-01-06 12:39 29 **********
361 2017-01-06 12:40 29 **********
362 2017-01-06 12:41 29 **********
363 2017-01-06 12:42 30 ***********
... ..( 2 skipped). .. ***********
366 2017-01-06 12:45 30 ***********
367 2017-01-06 12:46 31 ************
368 2017-01-06 12:47 31 ************
369 2017-01-06 12:48 31 ************
370 2017-01-06 12:49 32 *************
371 2017-01-06 12:50 32 *************
372 2017-01-06 12:51 32 *************
373 2017-01-06 12:52 33 **************
... ..( 17 skipped). .. **************
391 2017-01-06 13:10 33 **************
392 2017-01-06 13:11 34 ***************
... ..( 31 skipped). .. ***************
424 2017-01-06 13:43 34 ***************
425 2017-01-06 13:44 33 **************
... ..( 5 skipped). .. **************
431 2017-01-06 13:50 33 **************
432 2017-01-06 13:51 32 *************
... ..( 15 skipped). .. *************
448 2017-01-06 14:07 32 *************
449 2017-01-06 14:08 31 ************
... ..( 46 skipped). .. ************
18 2017-01-06 14:55 31 ************
19 2017-01-06 14:56 ? -
20 2017-01-06 14:57 27 ********
... ..( 7 skipped). .. ********
28 2017-01-06 15:05 27 ********
29 2017-01-06 15:06 28 *********
30 2017-01-06 15:07 28 *********
31 2017-01-06 15:08 28 *********
32 2017-01-06 15:09 29 **********
... ..( 9 skipped). .. **********
42 2017-01-06 15:19 29 **********
43 2017-01-06 15:20 30 ***********
... ..( 3 skipped). .. ***********
47 2017-01-06 15:24 30 ***********
48 2017-01-06 15:25 29 **********
... ..( 4 skipped). .. **********
53 2017-01-06 15:30 29 **********
54 2017-01-06 15:31 30 ***********
... ..( 6 skipped). .. ***********
61 2017-01-06 15:38 30 ***********
62 2017-01-06 15:39 31 ************
... ..( 97 skipped). .. ************
160 2017-01-06 17:17 31 ************
161 2017-01-06 17:18 32 *************
... ..( 13 skipped). .. *************
175 2017-01-06 17:32 32 *************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1854 Vendor specific
/dev/sdd
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Green
Device Model: WDC WD5000AACS-00ZUB0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01B01
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Fri Jan 6 17:32:43 2017 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13560) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 158) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 73
3 Spin_Up_Time PO---- 161 157 021 - 4933
4 Start_Stop_Count -O--CK 095 095 000 - 5430
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 088 088 000 - 9271
10 Spin_Retry_Count -O--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3052
192 Power-Off_Retract_Count -O--CK 200 200 000 - 365
193 Load_Cycle_Count -O--CK 157 157 000 - 130943
194 Temperature_Celsius -O---K 115 096 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 101 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 101 [4] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 0b 00 00 51 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 7d b0 e8 3d 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 d6 00 e0 e8 3d 7d b0 00 00 00 08 00:00:57.601 DEVICE RESET
00 f2 b0 e7 35 00 00 01 00 08 00 00 00 04:13:40.092 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 d6 00 e0 e7 35 f2 b0 00 00 00 08 00:00:57.601 DEVICE RESET
Error 100 [3] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 10 00 00 53 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 7d b0 e8 3d 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 00 00 00 e8 3d 7c ec 00 00 00 08 00:00:57.345 DEVICE RESET
00 f2 b0 e7 35 00 e1 01 d5 08 00 00 00 04:12:32.626 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 00 00 00 e7 35 f2 ec 00 00 00 08 00:00:57.345 DEVICE RESET
Error 99 [2] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 0b 00 00 51 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 f2 b0 e7 35 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 d6 00 e0 e7 35 f2 b0 00 00 00 08 00:00:57.601 DEVICE RESET
00 69 b0 e5 db 00 00 01 00 08 00 00 00 04:12:32.626 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 d6 00 e0 e5 db 69 b0 00 00 00 08 00:00:57.601 DEVICE RESET
Error 98 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 10 00 00 53 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 f2 b0 e7 35 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 00 00 00 e7 35 f2 ec 00 00 00 08 00:00:57.345 DEVICE RESET
00 69 b0 e5 db 00 e1 01 d5 08 00 00 00 04:11:03.913 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 00 00 00 e5 db 69 ec 00 00 00 08 00:00:57.345 DEVICE RESET
Error 97 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 0b 00 00 51 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 69 b0 e5 db 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 d6 00 e0 e5 db 69 b0 00 00 00 08 00:00:57.601 DEVICE RESET
00 48 b0 e5 5b 00 00 01 00 08 00 00 00 04:11:03.913 NOP [Reserved subcommand] [OBS-ACS-2]
08 00 08 00 3f e4 db 73 60 00 00 00 08 00:00:57.345 DEVICE RESET
Error 96 [23] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 10 00 00 53 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 69 b0 e5 db 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 01 00 00 00 e5 db 69 ec 00 00 00 08 00:00:57.345 DEVICE RESET
00 73 60 e4 db 00 e0 01 d6 08 00 00 00 04:10:31.112 NOP [Reserved subcommand] [OBS-ACS-2]
08 00 08 00 4f e4 db 73 60 00 00 00 08 00:00:16.128 DEVICE RESET
Error 95 [22] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 00 10 00 00 53 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 48 b0 e5 5b 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
08 00 08 00 3f e4 db 73 60 00 00 00 08 00:00:57.345 DEVICE RESET
00 72 60 e4 db 00 4f 00 08 08 00 00 00 04:09:58.387 NOP [Reserved subcommand] [OBS-ACS-2]
08 00 08 00 00 e4 db 6f 60 00 00 00 08 00:00:16.128 DEVICE RESET
Error 94 [21] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 00 00 00 51 40 00 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 cc 60 05 5b 00 00 00 00 00 00 00 16 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 00 02 00 00 05 5b c4 ef 00 00 00 00 00:00:10.008 NOP [Reserved subcommand] [OBS-ACS-2]
00 aa 60 05 4b 00 3f 18 01 00 00 00 00 00:05:47.050 NOP [Reserved subcommand] [OBS-ACS-2]
00 10 80 00 27 05 4b 9e 60 16 00 00 00 00:00:00.008 NOP [Reserved subcommand] [OBS-ACS-2]
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 27/32 Celsius
Lifetime Min/Max Temperature: 27/51 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/85 Celsius
Temperature History Size (Index): 128 (128)
Invalid Temperature History Size or Index
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x8000 4 1859 Vendor specific