Probe #9cd5d1485c of ASRock 770 Extreme3 Desktop Computer

Log: smartctl

/dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-21-amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD40EZRZ-00GXCB0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 80.00A80 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Mar 27 19:28:18 2023 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (45480) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 483) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 160 154 021 - 7000 4 Start_Stop_Count -O--CK 099 099 000 - 1653 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 073 073 000 - 19971 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 099 099 000 - 1653 192 Power-Off_Retract_Count -O--CK 200 200 000 - 81 193 Load_Cycle_Count -O--CK 181 181 000 - 58105 194 Temperature_Celsius -O---K 123 103 000 - 27 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 56 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 27 Celsius Power Cycle Min/Max Temperature: 20/27 Celsius Lifetime Min/Max Temperature: 16/47 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (182) Index Estimated Time Temperature Celsius 183 2023-03-27 11:31 25 ****** ... ..(126 skipped). .. ****** 310 2023-03-27 13:38 25 ****** 311 2023-03-27 13:39 26 ******* ... ..(110 skipped). .. ******* 422 2023-03-27 15:30 26 ******* 423 2023-03-27 15:31 25 ****** ... ..( 27 skipped). .. ****** 451 2023-03-27 15:59 25 ****** 452 2023-03-27 16:00 26 ******* ... ..( 64 skipped). .. ******* 39 2023-03-27 17:05 26 ******* 40 2023-03-27 17:06 25 ****** ... ..( 27 skipped). .. ****** 68 2023-03-27 17:34 25 ****** 69 2023-03-27 17:35 26 ******* ... ..( 55 skipped). .. ******* 125 2023-03-27 18:31 26 ******* 126 2023-03-27 18:32 27 ******** 127 2023-03-27 18:33 24 ***** ... ..( 16 skipped). .. ***** 144 2023-03-27 18:50 24 ***** 145 2023-03-27 18:51 25 ****** ... ..( 36 skipped). .. ****** 182 2023-03-27 19:28 25 ****** SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 1653 --- Lifetime Power-On Resets 0x01 0x010 4 19971 --- Power-on Hours 0x01 0x018 6 20418227498 --- Logical Sectors Written 0x01 0x020 6 13845681 --- Number of Write Commands 0x01 0x028 6 18791107848 --- Logical Sectors Read 0x01 0x030 6 60383111 --- Number of Read Commands 0x01 0x038 6 3176123264 --- Date and Time TimeStamp 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 19956 --- Spindle Motor Power-on Hours 0x03 0x010 4 1805 --- Head Flying Hours 0x03 0x018 4 58187 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 0 --- Read Recovery Attempts 0x03 0x030 4 0 --- Number of Mechanical Start Failures 0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors 0x03 0x040 4 81 --- Number of High Priority Unload Events 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 27 --- Current Temperature 0x05 0x010 1 25 --- Average Short Term Temperature 0x05 0x018 1 24 --- Average Long Term Temperature 0x05 0x020 1 47 --- Highest Temperature 0x05 0x028 1 19 --- Lowest Temperature 0x05 0x030 1 41 --- Highest Average Short Term Temperature 0x05 0x038 1 21 --- Lowest Average Short Term Temperature 0x05 0x040 1 37 --- Highest Average Long Term Temperature 0x05 0x048 1 23 --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 7880 --- Number of Hardware Resets 0x06 0x010 4 2895 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 40011 Vendor specific /dev/sdb smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-21-amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 860 EVO 500GB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVT01B6Q User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Mar 27 19:28:19 2023 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 098 098 000 - 5737 12 Power_Cycle_Count -O--CK 099 099 000 - 668 177 Wear_Leveling_Count PO--C- 099 099 000 - 4 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 074 059 000 - 26 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 64 241 Total_LBAs_Written -O--CK 099 099 000 - 4970380088 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce-0xcf SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 26 Celsius Power Cycle Min/Max Temperature: 22/40 Celsius Lifetime Min/Max Temperature: 20/40 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (2) Index Estimated Time Temperature Celsius 3 2023-03-26 22:10 25 ****** ... ..( 10 skipped). .. ****** 14 2023-03-27 00:00 25 ****** 15 2023-03-27 00:10 24 ***** ... ..( 2 skipped). .. ***** 18 2023-03-27 00:40 24 ***** 19 2023-03-27 00:50 31 ************ 20 2023-03-27 01:00 33 ************** 21 2023-03-27 01:10 33 ************** 22 2023-03-27 01:20 24 ***** 23 2023-03-27 01:30 25 ****** 24 2023-03-27 01:40 27 ******** 25 2023-03-27 01:50 ? - 26 2023-03-27 02:00 26 ******* 27 2023-03-27 02:10 25 ****** 28 2023-03-27 02:20 25 ****** 29 2023-03-27 02:30 26 ******* ... ..( 2 skipped). .. ******* 32 2023-03-27 03:00 26 ******* 33 2023-03-27 03:10 25 ****** 34 2023-03-27 03:20 25 ****** 35 2023-03-27 03:30 25 ****** 36 2023-03-27 03:40 24 ***** 37 2023-03-27 03:50 24 ***** 38 2023-03-27 04:00 24 ***** 39 2023-03-27 04:10 23 **** ... ..( 9 skipped). .. **** 49 2023-03-27 05:50 23 **** 50 2023-03-27 06:00 24 ***** ... ..( 2 skipped). .. ***** 53 2023-03-27 06:30 24 ***** 54 2023-03-27 06:40 25 ****** ... ..( 3 skipped). .. ****** 58 2023-03-27 07:20 25 ****** 59 2023-03-27 07:30 24 ***** 60 2023-03-27 07:40 25 ****** 61 2023-03-27 07:50 25 ****** 62 2023-03-27 08:00 25 ****** 63 2023-03-27 08:10 ? - 64 2023-03-27 08:20 ? - 65 2023-03-27 08:30 22 *** 66 2023-03-27 08:40 22 *** 67 2023-03-27 08:50 22 *** 68 2023-03-27 09:00 23 **** 69 2023-03-27 09:10 31 ************ 70 2023-03-27 09:20 22 *** 71 2023-03-27 09:30 22 *** 72 2023-03-27 09:40 23 **** 73 2023-03-27 09:50 22 *** ... ..( 4 skipped). .. *** 78 2023-03-27 10:40 22 *** 79 2023-03-27 10:50 25 ****** 80 2023-03-27 11:00 28 ********* 81 2023-03-27 11:10 29 ********** 82 2023-03-27 11:20 26 ******* 83 2023-03-27 11:30 24 ***** ... ..( 3 skipped). .. ***** 87 2023-03-27 12:10 24 ***** 88 2023-03-27 12:20 23 **** 89 2023-03-27 12:30 24 ***** 90 2023-03-27 12:40 23 **** 91 2023-03-27 12:50 23 **** 92 2023-03-27 13:00 25 ****** 93 2023-03-27 13:10 25 ****** 94 2023-03-27 13:20 24 ***** 95 2023-03-27 13:30 25 ****** 96 2023-03-27 13:40 25 ****** 97 2023-03-27 13:50 25 ****** 98 2023-03-27 14:00 26 ******* ... ..( 6 skipped). .. ******* 105 2023-03-27 15:10 26 ******* 106 2023-03-27 15:20 25 ****** ... ..( 2 skipped). .. ****** 109 2023-03-27 15:50 25 ****** 110 2023-03-27 16:00 26 ******* 111 2023-03-27 16:10 26 ******* 112 2023-03-27 16:20 24 ***** 113 2023-03-27 16:30 24 ***** 114 2023-03-27 16:40 24 ***** 115 2023-03-27 16:50 26 ******* ... ..( 5 skipped). .. ******* 121 2023-03-27 17:50 26 ******* 122 2023-03-27 18:00 24 ***** 123 2023-03-27 18:10 24 ***** 124 2023-03-27 18:20 25 ****** ... ..( 5 skipped). .. ****** 2 2023-03-27 19:20 25 ****** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 668 --- Lifetime Power-On Resets 0x01 0x010 4 5737 --- Power-on Hours 0x01 0x018 6 4970380088 --- Logical Sectors Written 0x01 0x020 6 55875681 --- Number of Write Commands 0x01 0x028 6 2789079686 --- Logical Sectors Read 0x01 0x030 6 76126976 --- Number of Read Commands 0x01 0x038 6 756000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 37 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 26 --- Current Temperature 0x05 0x020 1 40 --- Highest Temperature 0x05 0x028 1 20 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 4057 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 5 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC


Hardware for Linux and BSD

GitHub