Probe #9d7b061a4a of Gigabyte 8I945PLGE-RH Desktop Computer by NT Computer (ELEMENT 2.2660/80)

Log: smartctl

/dev/sda === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint P80 SD Device Model: SAMSUNG HD080HJ Serial Number: -- Firmware Version: WT100-41 User Capacity: 80 025 280 000 bytes [80,0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a Local Time is: Sat Dec 19 09:01:01 2015 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1872) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 31) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0 3 Spin_Up_Time POS--- 100 100 025 - 3904 4 Start_Stop_Count -O--CK 091 091 000 - 9455 5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0 7 Seek_Error_Rate POSR-- 253 253 051 - 0 8 Seek_Time_Performance P-S--K 253 253 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 36416 10 Spin_Retry_Count PO--CK 253 253 051 - 0 11 Calibration_Retry_Count -O--C- 253 253 000 - 0 12 Power_Cycle_Count -O--CK 096 096 000 - 4779 187 Reported_Uncorrect -O--CK 079 079 000 - 22 190 Airflow_Temperature_Cel -O---K 118 079 000 - 40 194 Temperature_Celsius -O---K 118 079 000 - 40 195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 23897845 196 Reallocated_Event_Count -O--CK 253 253 000 - 0 197 Current_Pending_Sector -O--C- 253 100 000 - 0 198 Offline_Uncorrectable ----CK 253 253 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0 201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0 202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (2 sectors) Invalid Error Log index = 0x0000, trying reserved byte (0x01) instead Device Error Count: 25 (device log contains only the most recent 8 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 25 [0] occurred at disk power-on lifetime: 34208 hours (1425 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 51 00 80 00 00 3a 02 00 df e6 00 Error: ABRT at LBA = 0x3e0200df = 1040318687 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ca 00 00 00 80 00 00 00 3a 02 df e6 00 04:44:32.438 WRITE DMA c8 00 00 00 20 00 00 00 57 3c 99 e1 00 04:44:32.438 READ DMA ca 00 00 00 80 00 00 00 3a 02 5f e6 00 04:44:32.438 WRITE DMA c8 00 00 00 40 00 00 00 57 3c 59 e1 00 04:44:32.438 READ DMA ca 00 00 00 80 00 00 00 3a 01 df e6 00 04:44:32.438 WRITE DMA Error 24 [7] occurred at disk power-on lifetime: 26216 hours (1092 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 51 00 80 00 00 f3 fe 00 27 e6 00 Error: ABRT at LBA = 0xf7fe0027 = 4160618535 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ca 00 00 00 80 00 00 00 f3 fe 27 e6 00 01:48:49.438 WRITE DMA ca 00 00 00 80 00 00 00 f3 fd a7 e6 00 01:48:49.438 WRITE DMA ca 00 00 00 80 00 00 00 f3 fd 27 e6 00 01:48:49.438 WRITE DMA ca 00 00 00 80 00 00 00 f3 fc a7 e6 00 01:48:49.438 WRITE DMA ca 00 00 00 80 00 00 00 f3 fc 27 e6 00 01:48:49.438 WRITE DMA Error 23 [6] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 00 00 00 60 2e bf e0 00 00:02:22.250 READ DMA c8 00 00 00 18 00 00 00 44 70 b1 e8 00 00:02:20.563 READ DMA c8 00 00 00 1e 00 00 00 44 74 54 e8 00 00:02:20.563 READ DMA c8 00 00 00 40 00 00 00 44 73 a9 e8 00 00:02:20.563 READ DMA c8 00 00 00 18 00 00 00 44 71 69 e8 00 00:02:20.563 READ DMA Error 22 [5] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 00 00 00 60 2e bf e0 00 00:02:20.438 READ DMA c8 00 00 00 03 00 00 00 be 14 87 e0 00 00:02:18.688 READ DMA c8 00 00 00 08 00 00 00 1b e8 67 e0 00 00:02:18.688 READ DMA c8 00 00 00 08 00 00 00 17 26 ef e0 00 00:02:18.625 READ DMA ca 00 00 00 08 00 00 00 61 38 1f e0 00 00:02:18.625 WRITE DMA Error 21 [4] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 d8 d8 00 08 00 00 00 60 2e bf e0 00 00:01:57.188 READ DMA ca d8 d8 00 08 00 00 00 5f b1 af e0 00 00:01:55.438 WRITE DMA c8 d8 d8 00 40 00 00 00 42 77 09 e8 00 00:01:55.438 READ DMA ca d8 d8 00 08 00 00 00 60 a0 6f e0 00 00:01:55.438 WRITE DMA Error 20 [3] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 d8 d8 00 08 00 00 00 60 2e bf e0 00 00:01:55.375 READ DMA c8 d8 d8 00 40 00 00 00 42 76 c9 e8 00 00:01:53.688 READ DMA c8 d8 d8 00 08 00 00 00 60 2e 7f e0 00 00:01:53.625 READ DMA c8 d8 d8 00 fc 00 00 00 42 d3 ce e8 00 00:01:53.625 READ DMA c8 d8 d8 00 03 00 00 00 42 d3 cb e8 00 00:01:53.625 READ DMA Error 19 [2] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 d8 d8 00 08 00 00 00 60 2e bf e0 00 00:01:52.875 READ DMA c8 d8 d8 00 01 00 00 00 00 00 00 e0 00 00:01:51.188 READ DMA Error 18 [1] occurred at disk power-on lifetime: 19751 hours (822 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 60 2e 00 bf e0 00 Error: UNC 8 sectors at LBA = 0x602e00bf = 1613627583 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 d8 d8 00 08 00 00 00 60 2e bf e0 00 00:01:51.125 READ DMA c8 d8 d8 00 08 00 00 00 42 65 ff e8 00 00:01:49.438 READ DMA c8 d8 d8 00 08 00 00 00 60 2e 97 e0 00 00:01:49.438 READ DMA c8 d8 d8 00 08 00 00 00 42 65 f7 e8 00 00:01:49.438 READ DMA c8 d8 d8 00 08 00 00 00 60 2e 8f e0 00 00:01:49.438 READ DMA SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Max Temperature: 42 Celsius Lifetime Max Temperature: 55 Celsius SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 10/55 Celsius Min/Max Temperature Limit: 5/60 Celsius Temperature History Size (Index): 128 (15) Index Estimated Time Temperature Celsius 16 2015-12-19 06:54 38 ******************* 17 2015-12-19 06:55 38 ******************* 18 2015-12-19 06:56 40 ********************* ... ..( 23 skipped). .. ********************* 42 2015-12-19 07:20 40 ********************* 43 2015-12-19 07:21 38 ******************* ... ..( 3 skipped). .. ******************* 47 2015-12-19 07:25 38 ******************* 48 2015-12-19 07:26 40 ********************* ... ..( 19 skipped). .. ********************* 68 2015-12-19 07:46 40 ********************* 69 2015-12-19 07:47 38 ******************* ... ..( 13 skipped). .. ******************* 83 2015-12-19 08:01 38 ******************* 84 2015-12-19 08:02 40 ********************* ... ..( 54 skipped). .. ********************* 11 2015-12-19 08:57 40 ********************* 12 2015-12-19 08:58 ? - 13 2015-12-19 08:59 40 ********************* 14 2015-12-19 09:00 40 ********************* 15 2015-12-19 09:01 40 ********************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x000a 2 18 Device-to-host register FISes sent due to a COMRESET 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x8001 2 0 Vendor specific


Hardware for Linux and BSD

GitHub