/dev/sda smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.2.12-1-default] (SUSE RPM) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.14 (AF) Device Model: ST500DM002-1BD142 Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: HP73 User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Jun 12 17:15:31 2023 WEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 600) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SCT capabilities: (0x103b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 117 099 006 - 148554944 3 Spin_Up_Time PO---K 100 100 000 - 0 4 Start_Stop_Count -O--CK 096 096 020 - 4360 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 232 7 Seek_Error_Rate POSR-K 087 060 030 - 528816958 9 Power_On_Hours -O--CK 073 073 000 - 24181 10 Spin_Retry_Count PO--CK 100 100 097 - 0 12 Power_Cycle_Count -O--CK 096 096 020 - 4358 180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 21224924 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 097 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 099 000 - 2 2 2 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 067 048 045 - 33 (Min/Max 21/34) 194 Temperature_Celsius -O---K 033 052 000 - 33 (0 8 0 0 0) 195 Hardware_ECC_Recovered -O-RCK 055 042 000 - 148554944 196 Reallocated_Event_Count -O--CK 100 100 036 - 232 197 Current_Pending_Sector -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 129 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xab GPL VS 1 Device vendor specific log 0xb0 GPL VS 2928 Device vendor specific log 0xbd GPL VS 252 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 24172 - # 2 Short offline Completed without error 00% 24164 - # 3 Short offline Completed without error 00% 24154 - # 4 Short offline Completed without error 00% 24151 - # 5 Short offline Completed without error 00% 24148 - # 6 Short offline Completed without error 00% 24139 - # 7 Short offline Completed without error 00% 24128 - # 8 Extended offline Completed without error 00% 24120 - # 9 Short offline Completed without error 00% 24113 - #10 Short offline Completed without error 00% 24104 - #11 Short offline Completed without error 00% 24096 - #12 Short offline Completed without error 00% 24087 - #13 Short offline Completed without error 00% 24079 - #14 Short offline Completed without error 00% 24070 - #15 Short offline Completed without error 00% 24059 - #16 Short offline Completed without error 00% 24049 - #17 Short offline Completed without error 00% 24040 - #18 Short offline Completed without error 00% 24028 - #19 Short offline Completed without error 00% 24019 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 33 Celsius Power Cycle Min/Max Temperature: 21/34 Celsius Lifetime Min/Max Temperature: 8/52 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 59 minutes Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (63) Index Estimated Time Temperature Celsius 64 2023-06-07 11:31 33 ************** 65 2023-06-07 12:30 32 ************* ... ..( 3 skipped). .. ************* 69 2023-06-07 16:26 32 ************* 70 2023-06-07 17:25 ? - 71 2023-06-07 18:24 24 ***** 72 2023-06-07 19:23 ? - 73 2023-06-07 20:22 19 - 74 2023-06-07 21:21 31 ************ ... ..( 5 skipped). .. ************ 80 2023-06-08 03:15 31 ************ 81 2023-06-08 04:14 ? - 82 2023-06-08 05:13 19 - 83 2023-06-08 06:12 31 ************ 84 2023-06-08 07:11 32 ************* ... ..( 2 skipped). .. ************* 87 2023-06-08 10:08 32 ************* 88 2023-06-08 11:07 31 ************ 89 2023-06-08 12:06 31 ************ 90 2023-06-08 13:05 ? - 91 2023-06-08 14:04 20 * 92 2023-06-08 15:03 35 **************** 93 2023-06-08 16:02 32 ************* ... ..( 3 skipped). .. ************* 97 2023-06-08 19:58 32 ************* 98 2023-06-08 20:57 31 ************ 99 2023-06-08 21:56 ? - 100 2023-06-08 22:55 21 ** 101 2023-06-08 23:54 32 ************* 102 2023-06-09 00:53 32 ************* 103 2023-06-09 01:52 32 ************* 104 2023-06-09 02:51 35 **************** 105 2023-06-09 03:50 ? - 106 2023-06-09 04:49 22 *** 107 2023-06-09 05:48 33 ************** 108 2023-06-09 06:47 32 ************* 109 2023-06-09 07:46 32 ************* 110 2023-06-09 08:45 ? - 111 2023-06-09 09:44 21 ** 112 2023-06-09 10:43 32 ************* 113 2023-06-09 11:42 32 ************* 114 2023-06-09 12:41 ? - 115 2023-06-09 13:40 21 ** 116 2023-06-09 14:39 ? - 117 2023-06-09 15:38 21 ** 118 2023-06-09 16:37 ? - 119 2023-06-09 17:36 21 ** 120 2023-06-09 18:35 36 ***************** 121 2023-06-09 19:34 35 **************** 122 2023-06-09 20:33 33 ************** 123 2023-06-09 21:32 33 ************** 124 2023-06-09 22:31 35 **************** 125 2023-06-09 23:30 33 ************** 126 2023-06-10 00:29 ? - 127 2023-06-10 01:28 24 ***** 0 2023-06-10 02:27 33 ************** 1 2023-06-10 03:26 ? - 2 2023-06-10 04:25 21 ** 3 2023-06-10 05:24 33 ************** 4 2023-06-10 06:23 33 ************** 5 2023-06-10 07:22 34 *************** 6 2023-06-10 08:21 34 *************** 7 2023-06-10 09:20 34 *************** 8 2023-06-10 10:19 ? - 9 2023-06-10 11:18 24 ***** 10 2023-06-10 12:17 35 **************** 11 2023-06-10 13:16 37 ****************** 12 2023-06-10 14:15 36 ***************** 13 2023-06-10 15:14 ? - 14 2023-06-10 16:13 23 **** 15 2023-06-10 17:12 33 ************** 16 2023-06-10 18:11 34 *************** 17 2023-06-10 19:10 34 *************** 18 2023-06-10 20:09 33 ************** 19 2023-06-10 21:08 33 ************** 20 2023-06-10 22:07 34 *************** 21 2023-06-10 23:06 ? - 22 2023-06-11 00:05 23 **** 23 2023-06-11 01:04 ? - 24 2023-06-11 02:03 21 ** 25 2023-06-11 03:02 33 ************** 26 2023-06-11 04:01 33 ************** 27 2023-06-11 05:00 ? - 28 2023-06-11 05:59 22 *** 29 2023-06-11 06:58 ? - 30 2023-06-11 07:57 22 *** 31 2023-06-11 08:56 33 ************** 32 2023-06-11 09:55 33 ************** 33 2023-06-11 10:54 ? - 34 2023-06-11 11:53 21 ** 35 2023-06-11 12:52 32 ************* 36 2023-06-11 13:51 33 ************** ... ..( 5 skipped). .. ************** 42 2023-06-11 19:45 33 ************** 43 2023-06-11 20:44 32 ************* 44 2023-06-11 21:43 ? - 45 2023-06-11 22:42 21 ** 46 2023-06-11 23:41 32 ************* 47 2023-06-12 00:40 33 ************** 48 2023-06-12 01:39 ? - 49 2023-06-12 02:38 27 ******** 50 2023-06-12 03:37 33 ************** ... ..( 2 skipped). .. ************** 53 2023-06-12 06:34 33 ************** 54 2023-06-12 07:33 ? - 55 2023-06-12 08:32 21 ** 56 2023-06-12 09:31 32 ************* ... ..( 4 skipped). .. ************* 61 2023-06-12 14:26 32 ************* 62 2023-06-12 15:25 33 ************** 63 2023-06-12 16:24 33 ************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS /dev/sdb smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.2.12-1-default] (SUSE RPM) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Green Device Model: WDC WD5000AZRX-00A8LB0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 01.01A01 User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Jun 12 17:15:32 2023 WEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 8580) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 96) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x30b5) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 138 3 Spin_Up_Time POS--K 137 129 021 - 4116 4 Start_Stop_Count -O--CK 093 093 000 - 7527 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 062 062 000 - 28184 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 094 094 000 - 6594 192 Power-Off_Retract_Count -O--CK 199 199 000 - 1236 193 Load_Cycle_Count -O--CK 110 110 000 - 270641 194 Temperature_Celsius -O---K 113 095 000 - 30 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 17 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 197 000 - 33 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) Device Error Count: 246 (device log contains only the most recent 24 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 246 [5] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:29:03.496 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:29:03.479 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:29:03.471 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:29:03.471 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:29:03.471 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 245 [4] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:28:54.352 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:54.335 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:54.327 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:54.327 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:54.327 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 244 [3] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:28:45.201 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:45.184 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:45.176 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:45.176 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:45.176 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 243 [2] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:28:36.042 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:36.025 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:36.016 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:36.016 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:36.016 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 242 [1] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:28:26.898 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:26.881 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:26.873 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:26.873 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:26.873 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 241 [0] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:28:17.741 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:17.582 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:17.574 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:17.574 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:17.574 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 240 [23] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 08 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 03 00 08 00 00 00 00 00 00 00 e0 08 07:28:08.450 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:08.434 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:28:08.426 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:28:08.426 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:28:08.426 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 239 [22] occurred at disk power-on lifetime: 9047 hours (376 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 ff 98 80 00 a0 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 08 00 e0 08 07:27:59.304 FLUSH CACHE EXT 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:27:59.287 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 08 07:27:59.279 IDENTIFY DEVICE ef 00 03 00 45 00 00 00 00 00 00 a0 08 07:27:59.279 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 08 07:27:59.279 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 28175 - # 2 Short offline Completed without error 00% 28166 - # 3 Short offline Completed without error 00% 28156 - # 4 Short offline Completed without error 00% 28153 - # 5 Short offline Completed without error 00% 28150 - # 6 Short offline Completed without error 00% 28141 - # 7 Short offline Completed without error 00% 28130 - # 8 Extended offline Completed without error 00% 28122 - # 9 Short offline Completed without error 00% 28114 - #10 Short offline Completed without error 00% 28105 - #11 Short offline Completed without error 00% 28097 - #12 Short offline Completed without error 00% 28088 - #13 Short offline Completed without error 00% 28080 - #14 Short offline Completed without error 00% 28071 - #15 Short offline Completed without error 00% 28060 - #16 Short offline Completed without error 00% 28050 - #17 Short offline Completed without error 00% 28041 - #18 Short offline Completed without error 00% 28029 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 30 Celsius Power Cycle Min/Max Temperature: 21/30 Celsius Lifetime Min/Max Temperature: 20/47 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (468) Index Estimated Time Temperature Celsius 469 2023-06-12 09:18 29 ********** 470 2023-06-12 09:19 30 *********** 471 2023-06-12 09:20 29 ********** ... ..( 27 skipped). .. ********** 21 2023-06-12 09:48 29 ********** 22 2023-06-12 09:49 30 *********** 23 2023-06-12 09:50 29 ********** ... ..( 69 skipped). .. ********** 93 2023-06-12 11:00 29 ********** 94 2023-06-12 11:01 30 *********** 95 2023-06-12 11:02 29 ********** ... ..( 5 skipped). .. ********** 101 2023-06-12 11:08 29 ********** 102 2023-06-12 11:09 30 *********** 103 2023-06-12 11:10 29 ********** ... ..( 2 skipped). .. ********** 106 2023-06-12 11:13 29 ********** 107 2023-06-12 11:14 30 *********** 108 2023-06-12 11:15 29 ********** ... ..( 2 skipped). .. ********** 111 2023-06-12 11:18 29 ********** 112 2023-06-12 11:19 30 *********** 113 2023-06-12 11:20 29 ********** ... ..( 6 skipped). .. ********** 120 2023-06-12 11:27 29 ********** 121 2023-06-12 11:28 30 *********** 122 2023-06-12 11:29 30 *********** 123 2023-06-12 11:30 29 ********** ... ..( 6 skipped). .. ********** 130 2023-06-12 11:37 29 ********** 131 2023-06-12 11:38 30 *********** 132 2023-06-12 11:39 29 ********** ... ..( 3 skipped). .. ********** 136 2023-06-12 11:43 29 ********** 137 2023-06-12 11:44 30 *********** 138 2023-06-12 11:45 30 *********** 139 2023-06-12 11:46 30 *********** 140 2023-06-12 11:47 29 ********** 141 2023-06-12 11:48 30 *********** ... ..( 6 skipped). .. *********** 148 2023-06-12 11:55 30 *********** 149 2023-06-12 11:56 29 ********** 150 2023-06-12 11:57 29 ********** 151 2023-06-12 11:58 30 *********** ... ..(132 skipped). .. *********** 284 2023-06-12 14:11 30 *********** 285 2023-06-12 14:12 28 ********* ... ..( 16 skipped). .. ********* 302 2023-06-12 14:29 28 ********* 303 2023-06-12 14:30 29 ********** ... ..( 91 skipped). .. ********** 395 2023-06-12 16:02 29 ********** 396 2023-06-12 16:03 30 *********** ... ..( 11 skipped). .. *********** 408 2023-06-12 16:15 30 *********** 409 2023-06-12 16:16 29 ********** 410 2023-06-12 16:17 30 *********** 411 2023-06-12 16:18 29 ********** ... ..( 9 skipped). .. ********** 421 2023-06-12 16:28 29 ********** 422 2023-06-12 16:29 28 ********* ... ..( 11 skipped). .. ********* 434 2023-06-12 16:41 28 ********* 435 2023-06-12 16:42 29 ********** ... ..( 28 skipped). .. ********** 464 2023-06-12 17:11 29 ********** 465 2023-06-12 17:12 30 *********** 466 2023-06-12 17:13 29 ********** 467 2023-06-12 17:14 29 ********** 468 2023-06-12 17:15 29 ********** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 30908 Vendor specific


Hardware for Linux and BSD

GitHub