/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Intel 545s Series SSDs
Device Model: INTEL SSDSC2KW256G8
Serial Number: --
LU WWN Device Id: 5 5cd2e4 ...
Firmware Version: LHF004C
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 (minor revision not indicated)
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue May 23 01:31:50 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Write SCT (Get) Feature Control Command failed: scsi error badly formed scsi parameters
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 15) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 10985
12 Power_Cycle_Count -O--CK 100 100 000 - 2906
170 Unknown_Attribute PO--CK 100 100 010 - 0
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Unknown_Attribute PO--CK 086 086 005 - 949205401771
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 2121
183 SATA_Downshift_Count -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 090 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Temperature_Case -O--CK 037 053 000 - 37 (Min/Max 9/53)
192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 2121
199 CRC_Error_Count -O--CK 100 100 000 - 92
225 Host_Writes_32MiB -O--CK 100 100 000 - 2091625
226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 0
227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 0
228 Workload_Minutes -O--CK 100 100 000 - 0
232 Available_Reservd_Space PO--CK 100 100 010 - 0
233 Media_Wearout_Indicator -O--CK 067 067 000 - 0
236 Unknown_Attribute -O--CK 067 067 000 - 0
241 Host_Writes_32MiB -O--CK 100 100 000 - 2091625
242 Host_Reads_32MiB -O--CK 100 100 000 - 1880442
249 NAND_Writes_1GiB -O--CK 100 100 000 - 57836
252 Unknown_Attribute -O--CK 100 100 000 - 221
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 20% 10873 -
# 2 Short offline Aborted by host 40% 10873 -
# 3 Short offline Aborted by host 90% 10873 -
# 4 Short offline Aborted by host 90% 10873 -
# 5 Short offline Completed without error 00% 10873 -
# 6 Short offline Aborted by host 00% 10867 -
# 7 Short offline Aborted by host 40% 10867 -
# 8 Short offline Aborted by host 90% 10867 -
# 9 Short offline Aborted by host 90% 10867 -
#10 Short offline Completed without error 00% 8087 -
#11 Short offline Aborted by host 60% 7997 -
#12 Short offline Aborted by host 70% 7997 -
#13 Short offline Aborted by host 70% 7997 -
#14 Short offline Completed without error 00% 7517 -
#15 Short offline Completed without error 00% 7516 -
#16 Short offline Completed without error 00% 7511 -
#17 Short offline Completed without error 00% 6983 -
#18 Short offline Completed without error 00% 6818 -
#19 Short offline Completed without error 00% 6615 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 46 Celsius
Power Cycle Min/Max Temperature: 35/52 Celsius
Lifetime Min/Max Temperature: 14/63 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/100 Celsius
Min/Max Temperature Limit: 0/100 Celsius
Temperature History Size (Index): 128 (73)
Index Estimated Time Temperature Celsius
74 2023-05-22 23:24 51 ********************************
75 2023-05-22 23:25 52 *********************************
76 2023-05-22 23:26 52 *********************************
77 2023-05-22 23:27 52 *********************************
78 2023-05-22 23:28 51 ********************************
79 2023-05-22 23:29 52 *********************************
... ..( 9 skipped). .. *********************************
89 2023-05-22 23:39 52 *********************************
90 2023-05-22 23:40 50 *******************************
91 2023-05-22 23:41 49 ******************************
... ..( 6 skipped). .. ******************************
98 2023-05-22 23:48 49 ******************************
99 2023-05-22 23:49 50 *******************************
... ..( 2 skipped). .. *******************************
102 2023-05-22 23:52 50 *******************************
103 2023-05-22 23:53 35 ****************
104 2023-05-22 23:54 39 ********************
105 2023-05-22 23:55 44 *************************
106 2023-05-22 23:56 44 *************************
107 2023-05-22 23:57 44 *************************
108 2023-05-22 23:58 46 ***************************
109 2023-05-22 23:59 46 ***************************
110 2023-05-23 00:00 41 **********************
111 2023-05-23 00:01 41 **********************
112 2023-05-23 00:02 41 **********************
113 2023-05-23 00:03 42 ***********************
114 2023-05-23 00:04 44 *************************
115 2023-05-23 00:05 41 **********************
116 2023-05-23 00:06 42 ***********************
117 2023-05-23 00:07 42 ***********************
118 2023-05-23 00:08 41 **********************
119 2023-05-23 00:09 41 **********************
120 2023-05-23 00:10 43 ************************
121 2023-05-23 00:11 42 ***********************
122 2023-05-23 00:12 43 ************************
123 2023-05-23 00:13 43 ************************
124 2023-05-23 00:14 43 ************************
125 2023-05-23 00:15 44 *************************
126 2023-05-23 00:16 44 *************************
127 2023-05-23 00:17 43 ************************
... ..( 2 skipped). .. ************************
2 2023-05-23 00:20 43 ************************
3 2023-05-23 00:21 44 *************************
... ..( 10 skipped). .. *************************
14 2023-05-23 00:32 44 *************************
15 2023-05-23 00:33 43 ************************
16 2023-05-23 00:34 43 ************************
17 2023-05-23 00:35 43 ************************
18 2023-05-23 00:36 44 *************************
19 2023-05-23 00:37 44 *************************
20 2023-05-23 00:38 46 ***************************
21 2023-05-23 00:39 45 **************************
22 2023-05-23 00:40 44 *************************
... ..( 2 skipped). .. *************************
25 2023-05-23 00:43 44 *************************
26 2023-05-23 00:44 45 **************************
27 2023-05-23 00:45 52 *********************************
28 2023-05-23 00:46 45 **************************
29 2023-05-23 00:47 45 **************************
30 2023-05-23 00:48 45 **************************
31 2023-05-23 00:49 46 ***************************
32 2023-05-23 00:50 45 **************************
33 2023-05-23 00:51 46 ***************************
34 2023-05-23 00:52 45 **************************
35 2023-05-23 00:53 46 ***************************
36 2023-05-23 00:54 47 ****************************
37 2023-05-23 00:55 48 *****************************
38 2023-05-23 00:56 45 **************************
39 2023-05-23 00:57 44 *************************
40 2023-05-23 00:58 44 *************************
41 2023-05-23 00:59 51 ********************************
42 2023-05-23 01:00 44 *************************
43 2023-05-23 01:01 43 ************************
44 2023-05-23 01:02 43 ************************
45 2023-05-23 01:03 43 ************************
46 2023-05-23 01:04 44 *************************
... ..( 4 skipped). .. *************************
51 2023-05-23 01:09 44 *************************
52 2023-05-23 01:10 43 ************************
53 2023-05-23 01:11 43 ************************
54 2023-05-23 01:12 43 ************************
55 2023-05-23 01:13 44 *************************
... ..( 3 skipped). .. *************************
59 2023-05-23 01:17 44 *************************
60 2023-05-23 01:18 49 ******************************
61 2023-05-23 01:19 45 **************************
62 2023-05-23 01:20 45 **************************
63 2023-05-23 01:21 49 ******************************
64 2023-05-23 01:22 49 ******************************
65 2023-05-23 01:23 51 ********************************
66 2023-05-23 01:24 52 *********************************
67 2023-05-23 01:25 52 *********************************
68 2023-05-23 01:26 46 ***************************
69 2023-05-23 01:27 46 ***************************
70 2023-05-23 01:28 44 *************************
71 2023-05-23 01:29 45 **************************
72 2023-05-23 01:30 46 ***************************
73 2023-05-23 01:31 51 ********************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2906 --- Lifetime Power-On Resets
0x01 0x010 4 10985 --- Power-on Hours
0x01 0x018 6 137076783427 --- Logical Sectors Written
0x01 0x020 6 1820535197 --- Number of Write Commands
0x01 0x028 6 123236709184 --- Logical Sectors Read
0x01 0x030 6 1541085602 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 2121 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 46 --- Current Temperature
0x05 0x010 1 52 --- Average Short Term Temperature
0x05 0x018 1 37 --- Average Long Term Temperature
0x05 0x020 1 59 --- Highest Temperature
0x05 0x028 1 22 --- Lowest Temperature
0x05 0x030 1 54 --- Highest Average Short Term Temperature
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
0x05 0x040 1 37 --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 85 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 35399 --- Number of Hardware Resets
0x06 0x018 4 92 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 14 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0005 2 0 R_ERR response for non-data FIS
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE4
Device Model: WDC WD1003FBYX-01Y7B1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01V02
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue May 23 01:31:50 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16860) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 166) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1
3 Spin_Up_Time POS--K 178 171 021 - 4075
4 Start_Stop_Count -O--CK 097 097 000 - 3621
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 047 047 000 - 38872
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2352
192 Power-Off_Retract_Count -O--CK 198 198 000 - 2074
193 Load_Cycle_Count -O--CK 200 200 000 - 1552
194 Temperature_Celsius -O---K 104 094 000 - 43
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 5742 hours (239 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 68 13 83 5a 40 00
Error: UNC at LBA = 0x6813835a = 1746109274
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 20 00 30 00 00 07 11 6b 40 40 00 01:33:03.843 READ FPDMA QUEUED
61 00 20 00 30 00 00 07 11 6a 00 40 00 01:33:03.843 WRITE FPDMA QUEUED
60 00 20 00 28 00 00 07 11 6b 60 40 00 01:33:03.836 READ FPDMA QUEUED
61 00 20 00 28 00 00 07 11 6a 20 40 00 01:33:03.836 WRITE FPDMA QUEUED
60 00 20 00 20 00 00 07 11 6b 00 40 00 01:33:03.836 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 5742 hours (239 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 68 13 83 5a 40 00
Error: UNC at LBA = 0x6813835a = 1746109274
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 00 00 00 68 13 83 00 40 00 01:33:01.936 READ FPDMA QUEUED
60 01 00 00 00 00 00 68 13 82 00 40 00 01:33:01.934 READ FPDMA QUEUED
60 01 00 00 00 00 00 68 13 81 00 40 00 01:33:01.933 READ FPDMA QUEUED
60 01 00 00 00 00 00 68 13 80 00 40 00 01:33:01.931 READ FPDMA QUEUED
60 01 00 00 00 00 00 68 13 7f 00 40 00 01:33:01.930 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 35201 -
# 2 Short offline Completed without error 00% 35177 -
# 3 Short offline Completed without error 00% 35154 -
# 4 Short offline Completed without error 00% 35130 -
# 5 Short offline Completed without error 00% 35106 -
# 6 Short offline Completed without error 00% 35082 -
# 7 Short offline Completed without error 00% 35058 -
# 8 Short offline Completed without error 00% 35033 -
# 9 Short offline Completed without error 00% 35009 -
#10 Short offline Completed without error 00% 34985 -
#11 Short offline Completed without error 00% 34962 -
#12 Short offline Completed without error 00% 34938 -
#13 Short offline Completed without error 00% 34915 -
#14 Short offline Completed without error 00% 34891 -
#15 Short offline Completed without error 00% 34867 -
#16 Short offline Completed without error 00% 34843 -
#17 Extended offline Interrupted (host reset) 60% 25601 -
#18 Short offline Completed without error 00% 4232 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 36/44 Celsius
Lifetime Min/Max Temperature: 27/53 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (26)
Index Estimated Time Temperature Celsius
27 2023-05-22 17:34 43 ************************
... ..( 43 skipped). .. ************************
71 2023-05-22 18:18 43 ************************
72 2023-05-22 18:19 44 *************************
73 2023-05-22 18:20 43 ************************
74 2023-05-22 18:21 44 *************************
75 2023-05-22 18:22 43 ************************
... ..( 5 skipped). .. ************************
81 2023-05-22 18:28 43 ************************
82 2023-05-22 18:29 44 *************************
... ..( 87 skipped). .. *************************
170 2023-05-22 19:57 44 *************************
171 2023-05-22 19:58 43 ************************
172 2023-05-22 19:59 44 *************************
... ..( 4 skipped). .. *************************
177 2023-05-22 20:04 44 *************************
178 2023-05-22 20:05 43 ************************
179 2023-05-22 20:06 44 *************************
180 2023-05-22 20:07 44 *************************
181 2023-05-22 20:08 44 *************************
182 2023-05-22 20:09 43 ************************
... ..( 27 skipped). .. ************************
210 2023-05-22 20:37 43 ************************
211 2023-05-22 20:38 42 ***********************
212 2023-05-22 20:39 43 ************************
213 2023-05-22 20:40 42 ***********************
214 2023-05-22 20:41 43 ************************
215 2023-05-22 20:42 42 ***********************
216 2023-05-22 20:43 43 ************************
217 2023-05-22 20:44 42 ***********************
... ..( 2 skipped). .. ***********************
220 2023-05-22 20:47 42 ***********************
221 2023-05-22 20:48 43 ************************
222 2023-05-22 20:49 42 ***********************
223 2023-05-22 20:50 43 ************************
224 2023-05-22 20:51 42 ***********************
225 2023-05-22 20:52 42 ***********************
226 2023-05-22 20:53 43 ************************
227 2023-05-22 20:54 43 ************************
228 2023-05-22 20:55 42 ***********************
229 2023-05-22 20:56 43 ************************
230 2023-05-22 20:57 43 ************************
231 2023-05-22 20:58 42 ***********************
232 2023-05-22 20:59 43 ************************
233 2023-05-22 21:00 43 ************************
234 2023-05-22 21:01 43 ************************
235 2023-05-22 21:02 42 ***********************
236 2023-05-22 21:03 43 ************************
... ..(105 skipped). .. ************************
342 2023-05-22 22:49 43 ************************
343 2023-05-22 22:50 42 ***********************
... ..( 26 skipped). .. ***********************
370 2023-05-22 23:17 42 ***********************
371 2023-05-22 23:18 43 ************************
372 2023-05-22 23:19 42 ***********************
373 2023-05-22 23:20 42 ***********************
374 2023-05-22 23:21 43 ************************
375 2023-05-22 23:22 42 ***********************
376 2023-05-22 23:23 43 ************************
377 2023-05-22 23:24 42 ***********************
378 2023-05-22 23:25 43 ************************
379 2023-05-22 23:26 42 ***********************
... ..( 3 skipped). .. ***********************
383 2023-05-22 23:30 42 ***********************
384 2023-05-22 23:31 43 ************************
... ..(119 skipped). .. ************************
26 2023-05-23 01:31 43 ************************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 36849 Vendor specific
/dev/sdc
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE4
Device Model: WDC WD1003FBYX-01Y7B1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01V02
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue May 23 01:31:50 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16680) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 164) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 3210
3 Spin_Up_Time POS--K 173 171 021 - 4350
4 Start_Stop_Count -O--CK 096 096 000 - 4163
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 043 043 000 - 41804
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2432
192 Power-Off_Retract_Count -O--CK 198 198 000 - 2077
193 Load_Cycle_Count -O--CK 200 200 000 - 2085
194 Temperature_Celsius -O---K 109 086 000 - 38
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 13
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 36856 -
# 2 Short offline Completed without error 00% 36832 -
# 3 Short offline Completed without error 00% 36808 -
# 4 Short offline Completed without error 00% 36784 -
# 5 Short offline Completed without error 00% 36760 -
# 6 Short offline Completed without error 00% 36736 -
# 7 Short offline Completed without error 00% 36712 -
# 8 Short offline Completed without error 00% 36688 -
# 9 Short offline Completed without error 00% 36664 -
#10 Short offline Completed without error 00% 36640 -
#11 Short offline Completed without error 00% 36616 -
#12 Short offline Completed without error 00% 36592 -
#13 Short offline Completed without error 00% 36568 -
#14 Short offline Completed without error 00% 36544 -
#15 Short offline Completed without error 00% 36528 -
#16 Short offline Completed without error 00% 36498 -
#17 Short offline Completed without error 00% 4151 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 31/39 Celsius
Lifetime Min/Max Temperature: 31/61 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (356)
Index Estimated Time Temperature Celsius
357 2023-05-22 17:34 37 ******************
... ..( 30 skipped). .. ******************
388 2023-05-22 18:05 37 ******************
389 2023-05-22 18:06 38 *******************
390 2023-05-22 18:07 38 *******************
391 2023-05-22 18:08 37 ******************
392 2023-05-22 18:09 37 ******************
393 2023-05-22 18:10 38 *******************
394 2023-05-22 18:11 37 ******************
395 2023-05-22 18:12 38 *******************
... ..( 4 skipped). .. *******************
400 2023-05-22 18:17 38 *******************
401 2023-05-22 18:18 37 ******************
402 2023-05-22 18:19 37 ******************
403 2023-05-22 18:20 38 *******************
... ..( 69 skipped). .. *******************
473 2023-05-22 19:30 38 *******************
474 2023-05-22 19:31 37 ******************
475 2023-05-22 19:32 38 *******************
476 2023-05-22 19:33 38 *******************
477 2023-05-22 19:34 37 ******************
... ..( 7 skipped). .. ******************
7 2023-05-22 19:42 37 ******************
8 2023-05-22 19:43 38 *******************
9 2023-05-22 19:44 37 ******************
10 2023-05-22 19:45 38 *******************
11 2023-05-22 19:46 37 ******************
12 2023-05-22 19:47 38 *******************
13 2023-05-22 19:48 38 *******************
14 2023-05-22 19:49 38 *******************
15 2023-05-22 19:50 37 ******************
16 2023-05-22 19:51 37 ******************
17 2023-05-22 19:52 38 *******************
... ..( 48 skipped). .. *******************
66 2023-05-22 20:41 38 *******************
67 2023-05-22 20:42 39 ********************
68 2023-05-22 20:43 38 *******************
... ..( 2 skipped). .. *******************
71 2023-05-22 20:46 38 *******************
72 2023-05-22 20:47 39 ********************
73 2023-05-22 20:48 38 *******************
74 2023-05-22 20:49 39 ********************
75 2023-05-22 20:50 38 *******************
76 2023-05-22 20:51 39 ********************
... ..( 84 skipped). .. ********************
161 2023-05-22 22:16 39 ********************
162 2023-05-22 22:17 38 *******************
163 2023-05-22 22:18 39 ********************
... ..( 2 skipped). .. ********************
166 2023-05-22 22:21 39 ********************
167 2023-05-22 22:22 38 *******************
168 2023-05-22 22:23 39 ********************
169 2023-05-22 22:24 39 ********************
170 2023-05-22 22:25 38 *******************
171 2023-05-22 22:26 39 ********************
172 2023-05-22 22:27 39 ********************
173 2023-05-22 22:28 39 ********************
174 2023-05-22 22:29 38 *******************
... ..( 3 skipped). .. *******************
178 2023-05-22 22:33 38 *******************
179 2023-05-22 22:34 39 ********************
180 2023-05-22 22:35 38 *******************
... ..( 19 skipped). .. *******************
200 2023-05-22 22:55 38 *******************
201 2023-05-22 22:56 37 ******************
202 2023-05-22 22:57 38 *******************
203 2023-05-22 22:58 37 ******************
... ..( 19 skipped). .. ******************
223 2023-05-22 23:18 37 ******************
224 2023-05-22 23:19 38 *******************
225 2023-05-22 23:20 37 ******************
226 2023-05-22 23:21 38 *******************
227 2023-05-22 23:22 38 *******************
228 2023-05-22 23:23 38 *******************
229 2023-05-22 23:24 37 ******************
230 2023-05-22 23:25 38 *******************
... ..( 48 skipped). .. *******************
279 2023-05-23 00:14 38 *******************
280 2023-05-23 00:15 37 ******************
281 2023-05-23 00:16 38 *******************
282 2023-05-23 00:17 38 *******************
283 2023-05-23 00:18 38 *******************
284 2023-05-23 00:19 37 ******************
285 2023-05-23 00:20 37 ******************
286 2023-05-23 00:21 37 ******************
287 2023-05-23 00:22 38 *******************
288 2023-05-23 00:23 38 *******************
289 2023-05-23 00:24 37 ******************
290 2023-05-23 00:25 38 *******************
291 2023-05-23 00:26 37 ******************
292 2023-05-23 00:27 37 ******************
293 2023-05-23 00:28 37 ******************
294 2023-05-23 00:29 38 *******************
... ..( 49 skipped). .. *******************
344 2023-05-23 01:19 38 *******************
345 2023-05-23 01:20 37 ******************
... ..( 10 skipped). .. ******************
356 2023-05-23 01:31 37 ******************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 36844 Vendor specific
/dev/sdd
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE4
Device Model: WDC WD1003FBYZ-010FB0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01V03
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue May 23 01:31:51 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 165) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 172 169 021 - 4366
4 Start_Stop_Count -O--CK 096 096 000 - 4371
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 064 064 000 - 26290
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2716
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1153
193 Load_Cycle_Count -O--CK 199 199 000 - 3217
194 Temperature_Celsius -O---K 112 092 000 - 35
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 1
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 1
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 [0] occurred at disk power-on lifetime: 25015 hours (1042 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 28 a9 24 98 40 00
Error: UNC at LBA = 0x28a92498 = 682173592
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 02 00 00 40 00 00 28 a9 25 00 40 08 03:12:35.621 READ FPDMA QUEUED
60 00 68 00 38 00 00 28 a9 24 98 40 08 03:12:35.621 READ FPDMA QUEUED
60 00 88 00 30 00 00 28 a9 24 10 40 08 03:12:35.621 READ FPDMA QUEUED
60 00 b8 00 28 00 00 28 a9 23 58 40 08 03:12:35.621 READ FPDMA QUEUED
60 01 f8 00 20 00 00 28 a9 21 60 40 08 03:12:35.621 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 24557 -
# 2 Short offline Completed without error 00% 24533 -
# 3 Short offline Completed without error 00% 24509 -
# 4 Short offline Completed without error 00% 24485 -
# 5 Short offline Completed without error 00% 24461 -
# 6 Short offline Completed without error 00% 24437 -
# 7 Short offline Completed without error 00% 24413 -
# 8 Short offline Completed without error 00% 24389 -
# 9 Short offline Completed without error 00% 24365 -
#10 Short offline Completed without error 00% 24341 -
#11 Short offline Completed without error 00% 24317 -
#12 Short offline Completed without error 00% 24293 -
#13 Short offline Completed without error 00% 24269 -
#14 Short offline Completed without error 00% 24245 -
#15 Short offline Completed without error 00% 24221 -
#16 Short offline Completed without error 00% 24197 -
#17 Short offline Completed without error 00% 23361 -
#18 Short offline Completed without error 00% 23318 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 31/36 Celsius
Lifetime Min/Max Temperature: 0/55 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (73)
Index Estimated Time Temperature Celsius
74 2023-05-22 17:34 36 *****************
... ..(107 skipped). .. *****************
182 2023-05-22 19:22 36 *****************
183 2023-05-22 19:23 35 ****************
... ..(305 skipped). .. ****************
11 2023-05-23 00:29 35 ****************
12 2023-05-23 00:30 36 *****************
... ..( 60 skipped). .. *****************
73 2023-05-23 01:31 36 *****************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 36849 Vendor specific
/dev/sde
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE4
Device Model: WDC WD1003FBYZ-010FB0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01V03
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue May 23 01:31:51 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16680) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 164) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 188 051 - 0
3 Spin_Up_Time POS--K 173 171 021 - 4341
4 Start_Stop_Count -O--CK 096 096 000 - 4825
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 057 057 000 - 31431
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3137
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1405
193 Load_Cycle_Count -O--CK 199 199 000 - 3423
194 Temperature_Celsius -O---K 112 086 000 - 35
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 102
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 1403 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1403 [10] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 58 00 00 03 2e b4 60 40 00 00:02:47.850 READ FPDMA QUEUED
60 00 08 00 50 00 00 07 de a7 a8 40 00 00:02:47.838 READ FPDMA QUEUED
61 00 08 00 48 00 00 00 bc e0 10 40 00 00:02:47.838 WRITE FPDMA QUEUED
60 01 00 00 c0 00 00 03 0c 80 28 40 00 00:02:47.746 READ FPDMA QUEUED
60 00 08 00 b8 00 00 07 dc 5d 10 40 00 00:02:47.746 READ FPDMA QUEUED
Error 1402 [9] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 01 00 00 c0 00 00 03 0c 80 28 40 00 00:02:45.939 READ FPDMA QUEUED
60 00 08 00 b8 00 00 07 dc 5d 10 40 00 00:02:45.939 READ FPDMA QUEUED
60 00 18 00 b0 00 00 00 48 a1 b8 40 00 00:02:45.939 READ FPDMA QUEUED
60 00 40 00 a8 00 00 12 49 30 42 40 00 00:02:45.939 READ FPDMA QUEUED
60 00 48 00 a0 00 00 18 40 c6 00 40 00 00:02:45.939 READ FPDMA QUEUED
Error 1401 [8] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 80 00 00 03 2e b4 60 40 00 00:02:43.944 READ FPDMA QUEUED
60 00 08 00 78 00 00 00 1c ca c0 40 00 00:02:43.944 READ FPDMA QUEUED
60 00 10 00 70 00 00 00 97 aa e8 40 00 00:02:43.939 READ FPDMA QUEUED
60 00 08 00 68 00 00 07 dc 5c e8 40 00 00:02:43.932 READ FPDMA QUEUED
60 01 00 00 60 00 00 00 97 a9 e8 40 00 00:02:43.929 READ FPDMA QUEUED
Error 1400 [7] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 40 00 68 00 00 00 2b 99 82 40 00 00:02:41.998 READ FPDMA QUEUED
61 00 38 00 60 00 00 00 0a b0 28 40 00 00:02:41.998 WRITE FPDMA QUEUED
60 00 40 00 58 00 00 00 18 08 68 40 00 00:02:41.998 READ FPDMA QUEUED
60 00 10 00 50 00 00 00 37 a4 72 40 00 00:02:41.998 READ FPDMA QUEUED
60 00 40 00 48 00 00 00 1d a4 7a 40 00 00:02:41.998 READ FPDMA QUEUED
Error 1399 [6] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 30 00 e0 00 00 00 37 a2 a2 40 00 00:02:40.020 READ FPDMA QUEUED
60 00 18 00 d8 00 00 00 48 a1 08 40 00 00:02:40.020 READ FPDMA QUEUED
60 00 20 00 d0 00 00 00 2b a3 3b 40 00 00:02:40.020 READ FPDMA QUEUED
61 00 08 00 c8 00 00 00 04 c0 68 40 00 00:02:40.020 WRITE FPDMA QUEUED
60 00 38 00 a8 00 00 00 31 28 c8 40 00 00:02:40.020 READ FPDMA QUEUED
Error 1398 [5] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: WP at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 b0 00 00 07 d6 29 08 40 00 00:02:36.299 WRITE FPDMA QUEUED
61 00 08 00 a8 00 00 00 60 bf 28 40 00 00:02:36.299 WRITE FPDMA QUEUED
61 00 08 00 a0 00 00 03 53 39 c0 40 00 00:02:36.298 WRITE FPDMA QUEUED
61 00 18 00 98 00 00 02 58 ca 88 40 00 00:02:36.298 WRITE FPDMA QUEUED
60 00 08 00 90 00 00 03 2e b4 60 40 00 00:02:36.298 READ FPDMA QUEUED
Error 1397 [4] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: UNC at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 20 00 88 00 00 03 2e b5 60 40 00 00:02:34.365 READ FPDMA QUEUED
60 01 00 00 80 00 00 03 2e b4 60 40 00 00:02:34.365 READ FPDMA QUEUED
61 00 78 00 78 00 00 05 7c d7 e0 40 00 00:02:34.364 WRITE FPDMA QUEUED
60 00 08 00 70 00 00 00 af e0 f0 40 00 00:02:34.364 READ FPDMA QUEUED
61 01 00 00 68 00 00 05 7c d6 e0 40 00 00:02:34.364 WRITE FPDMA QUEUED
Error 1396 [3] occurred at disk power-on lifetime: 28624 hours (1192 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 03 2e b4 63 40 00
Error: WP at LBA = 0x032eb463 = 53392483
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 58 00 f0 00 00 01 07 0b c0 40 00 00:02:32.158 WRITE FPDMA QUEUED
61 00 48 00 e8 00 00 00 0f b6 80 40 00 00:02:32.152 WRITE FPDMA QUEUED
61 00 20 00 e0 00 00 00 38 03 e0 40 00 00:02:32.152 WRITE FPDMA QUEUED
61 00 18 00 d8 00 00 00 37 f3 80 40 00 00:02:32.149 WRITE FPDMA QUEUED
61 00 08 00 c8 00 00 00 38 3b f8 40 00 00:02:32.149 WRITE FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 26267 -
# 2 Short offline Completed without error 00% 26243 -
# 3 Short offline Completed without error 00% 26219 -
# 4 Short offline Completed without error 00% 26195 -
# 5 Short offline Completed without error 00% 26171 -
# 6 Short offline Completed without error 00% 26147 -
# 7 Short offline Completed without error 00% 26123 -
# 8 Short offline Completed without error 00% 26099 -
# 9 Short offline Completed without error 00% 26075 -
#10 Short offline Completed without error 00% 26051 -
#11 Short offline Completed without error 00% 26027 -
#12 Short offline Completed without error 00% 26003 -
#13 Short offline Completed without error 00% 25979 -
#14 Short offline Completed without error 00% 25955 -
#15 Short offline Completed without error 00% 25939 -
#16 Short offline Completed without error 00% 25909 -
#17 Short offline Completed without error 00% 23380 -
#18 Short offline Completed without error 00% 23337 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 30/35 Celsius
Lifetime Min/Max Temperature: 0/61 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (292)
Index Estimated Time Temperature Celsius
293 2023-05-22 17:34 34 ***************
... ..( 43 skipped). .. ***************
337 2023-05-22 18:18 34 ***************
338 2023-05-22 18:19 35 ****************
... ..(258 skipped). .. ****************
119 2023-05-22 22:38 35 ****************
120 2023-05-22 22:39 34 ***************
... ..( 32 skipped). .. ***************
153 2023-05-22 23:12 34 ***************
154 2023-05-22 23:13 35 ****************
... ..( 47 skipped). .. ****************
202 2023-05-23 00:01 35 ****************
203 2023-05-23 00:02 34 ***************
... ..( 17 skipped). .. ***************
221 2023-05-23 00:20 34 ***************
222 2023-05-23 00:21 35 ****************
... ..( 35 skipped). .. ****************
258 2023-05-23 00:57 35 ****************
259 2023-05-23 00:58 33 **************
260 2023-05-23 00:59 33 **************
261 2023-05-23 01:00 33 **************
262 2023-05-23 01:01 34 ***************
... ..( 29 skipped). .. ***************
292 2023-05-23 01:31 34 ***************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 36845 Vendor specific
/dev/sdf
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.3-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE4
Device Model: WDC WD1003FBYX-01Y7B2
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01V03
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue May 23 01:31:51 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (16800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 165) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 197 051 - 0
3 Spin_Up_Time POS--K 173 170 021 - 4350
4 Start_Stop_Count -O--CK 096 096 000 - 4173
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 043 043 000 - 41870
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2433
192 Power-Off_Retract_Count -O--CK 198 198 000 - 2079
193 Load_Cycle_Count -O--CK 200 200 000 - 2097
194 Temperature_Celsius -O---K 111 094 000 - 36
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 199 000 - 58
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 36905 -
# 2 Short offline Completed without error 00% 36881 -
# 3 Short offline Completed without error 00% 36857 -
# 4 Short offline Completed without error 00% 36833 -
# 5 Short offline Completed without error 00% 36809 -
# 6 Short offline Completed without error 00% 36785 -
# 7 Short offline Completed without error 00% 36761 -
# 8 Short offline Completed without error 00% 36737 -
# 9 Short offline Completed without error 00% 36713 -
#10 Short offline Completed without error 00% 36689 -
#11 Short offline Completed without error 00% 36665 -
#12 Short offline Completed without error 00% 36641 -
#13 Short offline Completed without error 00% 36617 -
#14 Short offline Completed without error 00% 36593 -
#15 Short offline Completed without error 00% 36577 -
#16 Short offline Completed without error 00% 36547 -
#17 Short offline Completed without error 00% 4156 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 31/36 Celsius
Lifetime Min/Max Temperature: 0/53 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (366)
Index Estimated Time Temperature Celsius
367 2023-05-22 17:34 35 ****************
... ..(193 skipped). .. ****************
83 2023-05-22 20:48 35 ****************
84 2023-05-22 20:49 36 *****************
... ..(269 skipped). .. *****************
354 2023-05-23 01:19 36 *****************
355 2023-05-23 01:20 35 ****************
... ..( 10 skipped). .. ****************
366 2023-05-23 01:31 35 ****************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 36845 Vendor specific