/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.2-1-default] (SUSE RPM)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 870 EVO 1TB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: SVT02B6Q
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 27 21:11:15 2023 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 85) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 099 099 000 - 135
12 Power_Cycle_Count -O--CK 099 099 000 - 59
177 Wear_Leveling_Count PO--C- 100 100 000 - 0
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 065 058 000 - 35
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 54
241 Total_LBAs_Written -O--CK 099 099 000 - 356111823
252 Unknown_Attribute -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 117 -
# 2 Short offline Completed without error 00% 93 -
# 3 Short offline Completed without error 00% 69 -
# 4 Short offline Completed without error 00% 45 -
# 5 Short offline Completed without error 00% 21 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
256 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 25/40 Celsius
Lifetime Min/Max Temperature: 25/42 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (116)
Index Estimated Time Temperature Celsius
117 2023-05-27 00:00 31 ************
118 2023-05-27 00:10 31 ************
119 2023-05-27 00:20 30 ***********
120 2023-05-27 00:30 30 ***********
121 2023-05-27 00:40 30 ***********
122 2023-05-27 00:50 29 **********
... ..( 8 skipped). .. **********
3 2023-05-27 02:20 29 **********
4 2023-05-27 02:30 28 *********
... ..( 6 skipped). .. *********
11 2023-05-27 03:40 28 *********
12 2023-05-27 03:50 27 ********
... ..( 3 skipped). .. ********
16 2023-05-27 04:30 27 ********
17 2023-05-27 04:40 26 *******
... ..( 6 skipped). .. *******
24 2023-05-27 05:50 26 *******
25 2023-05-27 06:00 25 ******
... ..( 2 skipped). .. ******
28 2023-05-27 06:30 25 ******
29 2023-05-27 06:40 26 *******
... ..( 9 skipped). .. *******
39 2023-05-27 08:20 26 *******
40 2023-05-27 08:30 27 ********
41 2023-05-27 08:40 28 *********
42 2023-05-27 08:50 27 ********
43 2023-05-27 09:00 27 ********
44 2023-05-27 09:10 27 ********
45 2023-05-27 09:20 28 *********
... ..( 3 skipped). .. *********
49 2023-05-27 10:00 28 *********
50 2023-05-27 10:10 29 **********
51 2023-05-27 10:20 29 **********
52 2023-05-27 10:30 29 **********
53 2023-05-27 10:40 30 ***********
... ..( 2 skipped). .. ***********
56 2023-05-27 11:10 30 ***********
57 2023-05-27 11:20 31 ************
... ..( 3 skipped). .. ************
61 2023-05-27 12:00 31 ************
62 2023-05-27 12:10 32 *************
... ..( 5 skipped). .. *************
68 2023-05-27 13:10 32 *************
69 2023-05-27 13:20 33 **************
... ..( 4 skipped). .. **************
74 2023-05-27 14:10 33 **************
75 2023-05-27 14:20 34 ***************
... ..( 6 skipped). .. ***************
82 2023-05-27 15:30 34 ***************
83 2023-05-27 15:40 35 ****************
84 2023-05-27 15:50 35 ****************
85 2023-05-27 16:00 36 *****************
86 2023-05-27 16:10 37 ******************
87 2023-05-27 16:20 37 ******************
88 2023-05-27 16:30 36 *****************
89 2023-05-27 16:40 35 ****************
... ..( 8 skipped). .. ****************
98 2023-05-27 18:10 35 ****************
99 2023-05-27 18:20 36 *****************
100 2023-05-27 18:30 35 ****************
... ..( 6 skipped). .. ****************
107 2023-05-27 19:40 35 ****************
108 2023-05-27 19:50 36 *****************
109 2023-05-27 20:00 35 ****************
110 2023-05-27 20:10 35 ****************
111 2023-05-27 20:20 34 ***************
... ..( 2 skipped). .. ***************
114 2023-05-27 20:50 34 ***************
115 2023-05-27 21:00 35 ****************
116 2023-05-27 21:10 35 ****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 59 --- Lifetime Power-On Resets
0x01 0x010 4 135 --- Power-on Hours
0x01 0x018 6 356111823 --- Logical Sectors Written
0x01 0x020 6 5205532 --- Number of Write Commands
0x01 0x028 6 20494993 --- Logical Sectors Read
0x01 0x030 6 224698 --- Number of Read Commands
0x01 0x038 6 1644000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x020 1 42 --- Highest Temperature
0x05 0x028 1 25 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 36 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.2-1-default] (SUSE RPM)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: SAMSUNG MZ7TE256HMHP-000L7
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EXT09L6Q
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 27 21:11:15 2023 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Unexpected SCT status 0x0001 (action_code=4, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 80) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
9 Power_On_Hours -O--CK 098 098 000 - 8491
12 Power_Cycle_Count -O--CK 098 098 000 - 1275
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
177 Wear_Leveling_Count PO--C- 088 088 005 - 136
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 099 099 010 - 1
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 099 099 010 - 1
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 099 100 010 - 4382
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 099 099 010 - 1
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Uncorrectable_Error_Cnt -O--CK 099 099 000 - 1
190 Airflow_Temperature_Cel -O--CK 063 050 000 - 37
195 ECC_Error_Rate -O-RC- 199 199 000 - 1
198 Offline_Uncorrectable ----CK 099 099 000 - 1
199 CRC_Error_Count -OSRCK 100 100 000 - 0
233 Media_Wearout_Indicator -O-RCK 199 199 000 - 755293
234 Unknown_Samsung_Attr -O--C- 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 127
236 Unknown_Samsung_Attr -O--C- 099 099 000 - 90
237 Unknown_Samsung_Attr -O--C- 099 099 000 - 136
238 Unknown_Samsung_Attr -O--C- 099 099 000 - 1
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa5 GPL,SL VS 16 Device vendor specific log
0xce GPL,SL VS 16 Device vendor specific log
0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 102 -
# 2 Short offline Completed without error 00% 78 -
# 3 Short offline Completed without error 00% 55 -
# 4 Short offline Completed without error 00% 31 -
# 5 Short offline Completed without error 00% 7 -
# 6 Short offline Completed without error 00% 0 -
# 7 Short offline Completed without error 00% 49 -
# 8 Short offline Completed without error 00% 7 -
# 9 Short offline Completed without error 00% 189 -
#10 Short offline Aborted by host 00% 0 -
#11 Short offline Completed without error 00% 0 -
#12 Short offline Completed without error 00% 1 -
#13 Short offline Completed without error 00% 1 -
#14 Short offline Completed without error 00% 0 -
#15 Short offline Completed without error 00% 1 -
#16 Short offline Completed without error 00% 1 -
#17 Short offline Completed without error 00% 44 -
#18 Short offline Completed without error 00% 0 -
#19 Short offline Completed without error 00% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/50972
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (84)
Index Estimated Time Temperature Celsius
85 2023-05-27 00:00 35 ****************
86 2023-05-27 00:10 35 ****************
87 2023-05-27 00:20 34 ***************
... ..( 2 skipped). .. ***************
90 2023-05-27 00:50 34 ***************
91 2023-05-27 01:00 33 **************
... ..( 6 skipped). .. **************
98 2023-05-27 02:10 33 **************
99 2023-05-27 02:20 32 *************
... ..( 4 skipped). .. *************
104 2023-05-27 03:10 32 *************
105 2023-05-27 03:20 37 ******************
106 2023-05-27 03:30 32 *************
107 2023-05-27 03:40 32 *************
108 2023-05-27 03:50 31 ************
... ..( 4 skipped). .. ************
113 2023-05-27 04:40 31 ************
114 2023-05-27 04:50 30 ***********
... ..( 5 skipped). .. ***********
120 2023-05-27 05:50 30 ***********
121 2023-05-27 06:00 29 **********
... ..( 7 skipped). .. **********
1 2023-05-27 07:20 29 **********
2 2023-05-27 07:30 30 ***********
... ..( 8 skipped). .. ***********
11 2023-05-27 09:00 30 ***********
12 2023-05-27 09:10 31 ************
... ..( 3 skipped). .. ************
16 2023-05-27 09:50 31 ************
17 2023-05-27 10:00 32 *************
... ..( 4 skipped). .. *************
22 2023-05-27 10:50 32 *************
23 2023-05-27 11:00 33 **************
... ..( 2 skipped). .. **************
26 2023-05-27 11:30 33 **************
27 2023-05-27 11:40 34 ***************
... ..( 3 skipped). .. ***************
31 2023-05-27 12:20 34 ***************
32 2023-05-27 12:30 35 ****************
... ..( 5 skipped). .. ****************
38 2023-05-27 13:30 35 ****************
39 2023-05-27 13:40 36 *****************
... ..( 6 skipped). .. *****************
46 2023-05-27 14:50 36 *****************
47 2023-05-27 15:00 37 ******************
... ..( 6 skipped). .. ******************
54 2023-05-27 16:10 37 ******************
55 2023-05-27 16:20 38 *******************
... ..( 20 skipped). .. *******************
76 2023-05-27 19:50 38 *******************
77 2023-05-27 20:00 37 ******************
... ..( 6 skipped). .. ******************
84 2023-05-27 21:10 37 ******************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdc
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.2-1-default] (SUSE RPM)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 840 EVO 120GB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EXT0BB6Q
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 27 21:11:15 2023 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Unexpected SCT status 0x0001 (action_code=4, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4200) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 70) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 099 099 010 - 5
9 Power_On_Hours -O--CK 096 096 000 - 19954
12 Power_Cycle_Count -O--CK 099 099 000 - 211
177 Wear_Leveling_Count PO--C- 095 095 000 - 55
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 099 099 010 - 5
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 099 099 010 - 5
187 Uncorrectable_Error_Cnt -O--CK 099 099 000 - 9
190 Airflow_Temperature_Cel -O--CK 062 051 000 - 38
195 ECC_Error_Rate -O-RC- 199 199 000 - 9
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 165
241 Total_LBAs_Written -O--CK 099 099 000 - 21780406791
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 16 Device vendor specific log
0xce GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 102 -
# 2 Short offline Completed without error 00% 78 -
# 3 Short offline Completed without error 00% 55 -
# 4 Short offline Completed without error 00% 31 -
# 5 Short offline Completed without error 00% 7 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/98406
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (85)
Index Estimated Time Temperature Celsius
86 2023-05-27 00:00 36 *****************
87 2023-05-27 00:10 35 ****************
... ..( 2 skipped). .. ****************
90 2023-05-27 00:40 35 ****************
91 2023-05-27 00:50 34 ***************
... ..( 5 skipped). .. ***************
97 2023-05-27 01:50 34 ***************
98 2023-05-27 02:00 33 **************
... ..( 6 skipped). .. **************
105 2023-05-27 03:10 33 **************
106 2023-05-27 03:20 34 ***************
107 2023-05-27 03:30 33 **************
108 2023-05-27 03:40 32 *************
... ..( 3 skipped). .. *************
112 2023-05-27 04:20 32 *************
113 2023-05-27 04:30 31 ************
... ..( 5 skipped). .. ************
119 2023-05-27 05:30 31 ************
120 2023-05-27 05:40 30 ***********
... ..( 13 skipped). .. ***********
6 2023-05-27 08:00 30 ***********
7 2023-05-27 08:10 31 ************
... ..( 4 skipped). .. ************
12 2023-05-27 09:00 31 ************
13 2023-05-27 09:10 32 *************
... ..( 4 skipped). .. *************
18 2023-05-27 10:00 32 *************
19 2023-05-27 10:10 33 **************
... ..( 3 skipped). .. **************
23 2023-05-27 10:50 33 **************
24 2023-05-27 11:00 34 ***************
... ..( 2 skipped). .. ***************
27 2023-05-27 11:30 34 ***************
28 2023-05-27 11:40 35 ****************
... ..( 4 skipped). .. ****************
33 2023-05-27 12:30 35 ****************
34 2023-05-27 12:40 36 *****************
... ..( 5 skipped). .. *****************
40 2023-05-27 13:40 36 *****************
41 2023-05-27 13:50 37 ******************
... ..( 6 skipped). .. ******************
48 2023-05-27 15:00 37 ******************
49 2023-05-27 15:10 38 *******************
... ..( 13 skipped). .. *******************
63 2023-05-27 17:30 38 *******************
64 2023-05-27 17:40 39 ********************
... ..( 8 skipped). .. ********************
73 2023-05-27 19:10 39 ********************
74 2023-05-27 19:20 38 *******************
... ..( 10 skipped). .. *******************
85 2023-05-27 21:10 38 *******************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdd
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.3.2-1-default] (SUSE RPM)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K1000.C
Device Model: Hitachi HDS721010CLA332
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: JP4OA3EA
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat May 27 21:11:15 2023 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10223) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 170) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 134 134 054 - 100
3 Spin_Up_Time POS--- 127 127 024 - 302 (Average 294)
4 Start_Stop_Count -O--C- 100 100 000 - 460
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 2
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 138 138 020 - 31
9 Power_On_Hours -O--C- 096 096 000 - 28904
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 460
192 Power-Off_Retract_Count -O--CK 100 100 000 - 530
193 Load_Cycle_Count -O--C- 100 100 000 - 530
194 Temperature_Celsius -O---- 146 146 000 - 41 (Min/Max 18/49)
196 Reallocated_Event_Count -O--CK 100 100 000 - 2
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 7 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log [OBS-8]
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 0 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 28886 -
# 2 Short offline Completed without error 00% 28862 -
# 3 Short offline Completed without error 00% 28838 -
# 4 Short offline Completed without error 00% 28814 -
# 5 Short offline Completed without error 00% 28790 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 27/44 Celsius
Lifetime Min/Max Temperature: 18/49 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (57)
Index Estimated Time Temperature Celsius
58 2023-05-27 19:04 42 ***********************
59 2023-05-27 19:05 42 ***********************
60 2023-05-27 19:06 42 ***********************
61 2023-05-27 19:07 41 **********************
62 2023-05-27 19:08 42 ***********************
63 2023-05-27 19:09 42 ***********************
64 2023-05-27 19:10 41 **********************
... ..(120 skipped). .. **********************
57 2023-05-27 21:11 41 **********************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 460 --- Lifetime Power-On Resets
0x01 0x010 4 28904 --- Power-on Hours
0x01 0x018 6 2260243532 --- Logical Sectors Written
0x01 0x020 6 39115009 --- Number of Write Commands
0x01 0x028 6 1049384764156 --- Logical Sectors Read
0x01 0x030 6 24425386 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 28898 --- Spindle Motor Power-on Hours
0x03 0x010 4 28898 --- Head Flying Hours
0x03 0x018 4 530 --- Head Load Events
0x03 0x020 4 2 --- Number of Reallocated Logical Sectors
0x03 0x028 4 51 --- Read Recovery Attempts
0x03 0x030 4 2 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 499 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 38 N-- Average Short Term Temperature
0x05 0x018 1 36 N-- Average Long Term Temperature
0x05 0x020 1 49 --- Highest Temperature
0x05 0x028 1 18 --- Lowest Temperature
0x05 0x030 1 45 N-- Highest Average Short Term Temperature
0x05 0x038 1 0 N-- Lowest Average Short Term Temperature
0x05 0x040 1 42 N-- Highest Average Long Term Temperature
0x05 0x048 1 0 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2353 --- Number of Hardware Resets
0x06 0x010 4 870 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS