/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.13.11-gentoo] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 840 EVO 120GB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EXT0CB6Q
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Aug 19 21:44:29 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Unexpected SCT status 0x0001 (action_code=4, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4200) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 70) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 097 097 000 - 12340
12 Power_Cycle_Count -O--CK 097 097 000 - 2791
177 Wear_Leveling_Count PO--C- 091 091 000 - 97
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 071 046 000 - 29
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 142
241 Total_LBAs_Written -O--CK 099 099 000 - 19551840681
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 16 Device vendor specific log
0xce GPL,SL VS 16 Device vendor specific log
0xde SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/73888
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (73)
Index Estimated Time Temperature Celsius
74 2021-08-19 00:30 ? -
... ..( 53 skipped). .. -
0 2021-08-19 09:30 ? -
1 2021-08-19 09:40 24 *****
2 2021-08-19 09:50 26 *******
3 2021-08-19 10:00 27 ********
4 2021-08-19 10:10 28 *********
... ..( 2 skipped). .. *********
7 2021-08-19 10:40 28 *********
8 2021-08-19 10:50 29 **********
... ..( 2 skipped). .. **********
11 2021-08-19 11:20 29 **********
12 2021-08-19 11:30 28 *********
... ..( 17 skipped). .. *********
30 2021-08-19 14:30 28 *********
31 2021-08-19 14:40 29 **********
32 2021-08-19 14:50 29 **********
33 2021-08-19 15:00 29 **********
34 2021-08-19 15:10 28 *********
... ..( 11 skipped). .. *********
46 2021-08-19 17:10 28 *********
47 2021-08-19 17:20 27 ********
48 2021-08-19 17:30 28 *********
49 2021-08-19 17:40 28 *********
50 2021-08-19 17:50 29 **********
... ..( 5 skipped). .. **********
56 2021-08-19 18:50 29 **********
57 2021-08-19 19:00 28 *********
... ..( 2 skipped). .. *********
60 2021-08-19 19:30 28 *********
61 2021-08-19 19:40 29 **********
62 2021-08-19 19:50 29 **********
63 2021-08-19 20:00 29 **********
64 2021-08-19 20:10 28 *********
... ..( 3 skipped). .. *********
68 2021-08-19 20:50 28 *********
69 2021-08-19 21:00 29 **********
... ..( 3 skipped). .. **********
73 2021-08-19 21:40 29 **********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdb
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.13.11-gentoo] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Crucial_CT120M500SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU03
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Aug 19 21:44:29 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 555) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 9) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 18
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 13811
12 Power_Cycle_Count -O--CK 100 100 000 - 4912
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 089 089 000 - 332
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 148
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1990
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 065 045 000 - 35 (Min/Max -10/55)
196 Reallocated_Event_Count -O--CK 100 100 000 - 16
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 4
202 Percent_Lifetime_Remain P---CK 089 089 000 - 11
206 Write_Error_Rate -OSR-- 100 100 000 - 0
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 --- - 16838913119
247 Host_Program_Page_Count -O--CK 100 100 --- - 531534977
248 FTL_Program_Page_Count -O--CK 100 100 --- - 2060986262
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 13766 -
# 2 Vendor (0xff) Completed without error 00% 12524 -
# 3 Vendor (0xff) Completed without error 00% 12501 -
# 4 Vendor (0xff) Completed without error 00% 12489 -
# 5 Vendor (0xff) Completed without error 00% 12470 -
# 6 Vendor (0xff) Completed without error 00% 12461 -
# 7 Vendor (0xff) Completed without error 00% 12427 -
# 8 Vendor (0xff) Completed without error 00% 12417 -
# 9 Vendor (0xff) Completed without error 00% 12407 -
#10 Vendor (0xff) Completed without error 00% 12404 -
#11 Vendor (0xff) Completed without error 00% 12393 -
#12 Vendor (0xff) Completed without error 00% 12383 -
#13 Vendor (0xff) Completed without error 00% 12369 -
#14 Vendor (0xff) Completed without error 00% 12033 -
#15 Vendor (0xff) Completed without error 00% 11943 -
#16 Vendor (0xff) Completed without error 00% 11928 -
#17 Vendor (0xff) Completed without error 00% 11908 -
#18 Vendor (0xff) Completed without error 00% 11743 -
#19 Vendor (0xff) Completed without error 00% 11705 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 22/35 Celsius
Lifetime Min/Max Temperature: -10/55 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (359)
Index Estimated Time Temperature Celsius
360 2021-08-19 13:47 34 ***************
... ..( 34 skipped). .. ***************
395 2021-08-19 14:22 34 ***************
396 2021-08-19 14:23 33 **************
... ..( 20 skipped). .. **************
417 2021-08-19 14:44 33 **************
418 2021-08-19 14:45 34 ***************
... ..( 43 skipped). .. ***************
462 2021-08-19 15:29 34 ***************
463 2021-08-19 15:30 35 ****************
... ..( 13 skipped). .. ****************
477 2021-08-19 15:44 35 ****************
0 2021-08-19 15:45 33 **************
... ..( 34 skipped). .. **************
35 2021-08-19 16:20 33 **************
36 2021-08-19 16:21 34 ***************
... ..( 49 skipped). .. ***************
86 2021-08-19 17:11 34 ***************
87 2021-08-19 17:12 33 **************
... ..(138 skipped). .. **************
226 2021-08-19 19:31 33 **************
227 2021-08-19 19:32 34 ***************
... ..( 92 skipped). .. ***************
320 2021-08-19 21:05 34 ***************
321 2021-08-19 21:06 33 **************
... ..( 15 skipped). .. **************
337 2021-08-19 21:22 33 **************
338 2021-08-19 21:23 34 ***************
... ..( 20 skipped). .. ***************
359 2021-08-19 21:44 34 ***************
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 4912 --- Lifetime Power-On Resets
0x01 0x010 4 13811 --- Power-on Hours
0x01 0x018 6 16838913119 --- Logical Sectors Written
0x01 0x020 6 148610880 --- Number of Write Commands
0x01 0x028 6 29281622885 --- Logical Sectors Read
0x01 0x030 6 442132755 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 4861 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 33 --- Average Long Term Temperature
0x05 0x020 1 55 --- Highest Temperature
0x05 0x028 1 -10 --- Lowest Temperature
0x05 0x030 1 53 --- Highest Average Short Term Temperature
0x05 0x038 1 -10 --- Lowest Average Short Term Temperature
0x05 0x040 1 45 --- Highest Average Long Term Temperature
0x05 0x048 1 23 --- Lowest Average Long Term Temperature
0x05 0x050 4 - --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 499 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 4 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
/dev/sdc
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.13.11-gentoo] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue
Device Model: WDC WD10EZEX-60WN4A1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 03.01A03
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Aug 19 21:44:29 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10800) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 113) minutes.
SCT capabilities: (0x303d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 172 167 021 - 2383
4 Start_Stop_Count -O--CK 099 099 000 - 1687
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 094 094 000 - 4859
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 967
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 067 059 040 - 33 (Min/Max 22/33)
192 Power-Off_Retract_Count -O--CK 200 200 000 - 60
193 Load_Cycle_Count -O--CK 198 198 000 - 6505
194 Temperature_Celsius -O---K 110 102 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0d GPL,SL R/O 8 LPS Mis-alignment log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 402 Device vendor specific log
0xb6 SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 48 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 22/33 Celsius
Lifetime Min/Max Temperature: 12/41 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (40)
Index Estimated Time Temperature Celsius
41 2021-08-19 19:37 33 **************
42 2021-08-19 19:38 33 **************
43 2021-08-19 19:39 33 **************
44 2021-08-19 19:40 32 *************
45 2021-08-19 19:41 33 **************
46 2021-08-19 19:42 32 *************
... ..( 6 skipped). .. *************
53 2021-08-19 19:49 32 *************
54 2021-08-19 19:50 33 **************
55 2021-08-19 19:51 33 **************
56 2021-08-19 19:52 33 **************
57 2021-08-19 19:53 32 *************
... ..( 26 skipped). .. *************
84 2021-08-19 20:20 32 *************
85 2021-08-19 20:21 31 ************
86 2021-08-19 20:22 31 ************
87 2021-08-19 20:23 32 *************
88 2021-08-19 20:24 32 *************
89 2021-08-19 20:25 31 ************
... ..( 23 skipped). .. ************
113 2021-08-19 20:49 31 ************
114 2021-08-19 20:50 32 *************
... ..( 5 skipped). .. *************
120 2021-08-19 20:56 32 *************
121 2021-08-19 20:57 33 **************
... ..( 46 skipped). .. **************
40 2021-08-19 21:44 33 **************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 967 --- Lifetime Power-On Resets
0x01 0x010 4 4859 --- Power-on Hours
0x01 0x018 6 7331334173 --- Logical Sectors Written
0x01 0x020 6 51622309 --- Number of Write Commands
0x01 0x028 6 9307704085 --- Logical Sectors Read
0x01 0x030 6 58655364 --- Number of Read Commands
0x01 0x038 6 312530816 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 4481 --- Spindle Motor Power-on Hours
0x03 0x010 4 2494 --- Head Flying Hours
0x03 0x018 4 6566 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 4 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
0x03 0x040 4 60 --- Number of High Priority Unload Events
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 31 --- Average Short Term Temperature
0x05 0x018 1 30 --- Average Long Term Temperature
0x05 0x020 1 41 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 37 --- Highest Average Short Term Temperature
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
0x05 0x040 1 32 --- Highest Average Long Term Temperature
0x05 0x048 1 29 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4586 --- Number of Hardware Resets
0x06 0x010 4 1939 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 44349 Vendor specific
/dev/sdd
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.13.11-gentoo] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3320620AS
Serial Number: --
Firmware Version: 3.AAK
User Capacity: 320,071,851,520 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Thu Aug 19 21:44:29 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 115) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 110 092 006 - 116825867
3 Spin_Up_Time PO---- 095 095 000 - 0
4 Start_Stop_Count -O--CK 091 091 020 - 9829
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 078 060 030 - 58805422
9 Power_On_Hours -O--CK 073 073 000 - 23836
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 095 095 020 - 5566
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 057 030 045 Past 43 (Min/Max 21/43)
194 Temperature_Celsius -O---K 043 070 000 - 43 (0 12 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 057 050 000 - 81395070
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 82 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 82 [1] occurred at disk power-on lifetime: 6245 hours (260 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 00:02:02.034 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 00:02:02.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 00:02:02.000 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 00:02:02.000 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:01.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 81 [0] occurred at disk power-on lifetime: 6241 hours (260 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 01:01:09.788 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 01:01:09.706 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 01:01:09.648 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 01:01:11.339 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 01:01:11.279 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 80 [19] occurred at disk power-on lifetime: 4943 hours (205 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 00:55:05.965 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 00:55:05.965 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 00:55:05.965 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 00:55:05.883 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:55:05.824 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 79 [18] occurred at disk power-on lifetime: 4796 hours (199 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 06:48:40.814 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 06:48:40.733 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 06:48:40.674 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 06:48:42.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 06:48:42.669 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 78 [17] occurred at disk power-on lifetime: 6245 hours (260 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 00:02:02.034 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 00:02:02.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 00:02:02.000 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 00:02:02.000 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:01.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 77 [16] occurred at disk power-on lifetime: 6241 hours (260 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 01:01:09.788 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 01:01:09.706 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 01:01:09.648 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 01:01:11.339 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 01:01:11.279 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 76 [15] occurred at disk power-on lifetime: 4943 hours (205 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 00:55:05.965 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 00:55:05.965 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 00:55:05.965 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 00:55:05.883 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:55:05.824 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 75 [14] occurred at disk power-on lifetime: 4796 hours (199 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 00 00 00 00 00 e5 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 25 e2 00 42 6e e5 00 06:48:40.814 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 25 ea 00 42 af e0 00 06:48:40.733 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 25 ea 00 42 af e0 00 06:48:40.674 READ MULTIPLE EXT
37 00 00 00 00 00 25 ea 00 42 af e5 00 06:48:42.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 00 00 00 00 00 e0 00 06:48:42.669 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS