/dev/nvme0n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Seagate FireCuda 530 ZP2000GM30013
Serial Number: --
Firmware Version: SU6SM001
PCI Vendor/Subsystem ID: 0x1bb1
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 2,000,398,934,016 [2.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Nov 17 00:25:52 2022 CET
Firmware Updates (0x18): 4 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.80W - - 0 0 0 0 0 0
1 + 2.90W - - 1 1 1 1 0 0
2 + 2.80W - - 2 2 2 2 0 0
3 - 0.0250W - - 3 3 3 3 2500 7500
4 - 0.0050W - - 4 4 4 4 10500 65000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 31 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 98,018,265 [50.1 TB]
Data Units Written: 130,244,426 [66.6 TB]
Host Read Commands: 1,025,445,955
Host Write Commands: 2,694,237,793
Controller Busy Time: 10,867
Power Cycles: 261
Power On Hours: 6,966
Unsafe Shutdowns: 111
Media and Data Integrity Errors: 0
Error Information Log Entries: 2,006
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 2006 0 0x0011 0x4004 0x028 0 0 -
/dev/nvme1n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Seagate FireCuda 530 ZP2000GM30013
Serial Number: --
Firmware Version: SU6SM001
PCI Vendor/Subsystem ID: 0x1bb1
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 2,000,398,934,016 [2.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Nov 17 00:25:52 2022 CET
Firmware Updates (0x18): 4 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.80W - - 0 0 0 0 0 0
1 + 2.90W - - 1 1 1 1 0 0
2 + 2.80W - - 2 2 2 2 0 0
3 - 0.0250W - - 3 3 3 3 2500 7500
4 - 0.0050W - - 4 4 4 4 10500 65000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 29 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 50,435,067 [25.8 TB]
Data Units Written: 55,674,063 [28.5 TB]
Host Read Commands: 440,358,288
Host Write Commands: 608,199,345
Controller Busy Time: 3,797
Power Cycles: 261
Power On Hours: 6,968
Unsafe Shutdowns: 112
Media and Data Integrity Errors: 0
Error Information Log Entries: 2,004
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 2004 0 0x0001 0x4004 0x028 0 0 -
/dev/nvme2n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Seagate FireCuda 530 ZP4000GM30013
Serial Number: --
Firmware Version: SU6SM001
PCI Vendor/Subsystem ID: 0x1bb1
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 4,000,787,030,016 [4.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 4,000,787,030,016 [4.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Nov 17 00:25:52 2022 CET
Firmware Updates (0x18): 4 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.80W - - 0 0 0 0 0 0
1 + 7.10W - - 1 1 1 1 0 0
2 + 5.20W - - 2 2 2 2 0 0
3 - 0.0620W - - 3 3 3 3 2500 7500
4 - 0.0440W - - 4 4 4 4 10500 65000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 69,755,268 [35.7 TB]
Data Units Written: 35,493,197 [18.1 TB]
Host Read Commands: 818,178,640
Host Write Commands: 1,186,158,695
Controller Busy Time: 5,326
Power Cycles: 221
Power On Hours: 6,404
Unsafe Shutdowns: 96
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,746
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 1746 0 0x001d 0x4004 0x028 0 0 -
/dev/nvme3n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Micron_7400_MTFDKBG3T8TDZ
Serial Number: --
Firmware Version: E1MU23BC
PCI Vendor/Subsystem ID: 0x1344
IEEE OUI Identifier: 0x00a075
Total NVM Capacity: 3,840,755,982,336 [3.84 TB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 128
Namespace 1 Size/Capacity: 3,840,755,982,336 [3.84 TB]
Namespace 1 Utilization: 1,530,015,084,544 [1.53 TB]
Namespace 1 Formatted LBA Size: 4096
Namespace 1 IEEE EUI-64: 00a075 ...
Local Time is: Thu Nov 17 00:25:52 2022 CET
Firmware Updates (0x17): 3 Slots, Slot 1 R/O, no Reset required
Optional Admin Commands (0x005e): Format Frmw_DL NS_Mngmt Self_Test MI_Snd/Rec
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 1024 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x16): NA_Fields Dea/Unw_Error NP_Fields
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.25W - - 0 0 0 0 0 0
1 + 7.50W - - 0 0 0 0 10 10
2 + 7.50W - - 0 0 0 0 10 10
3 + 7.50W - - 0 0 0 0 10 10
4 + 5.50W - - 0 0 0 0 10 10
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 - 512 0 2
1 + 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 67,941,109 [34.7 TB]
Data Units Written: 46,201,888 [23.6 TB]
Host Read Commands: 927,046,877
Host Write Commands: 1,546,559,757
Controller Busy Time: 2,845
Power Cycles: 203
Power On Hours: 5,629
Unsafe Shutdowns: 92
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,786
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 51 Celsius
Temperature Sensor 2: 46 Celsius
Temperature Sensor 3: 39 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 1786 0 0x0002 0x8004 0x028 0 0 -
/dev/nvme4n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Micron_7400_MTFDKBG3T8TDZ
Serial Number: --
Firmware Version: E1MU23BC
PCI Vendor/Subsystem ID: 0x1344
IEEE OUI Identifier: 0x00a075
Total NVM Capacity: 3,840,755,982,336 [3.84 TB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 128
Namespace 1 Size/Capacity: 3,840,755,982,336 [3.84 TB]
Namespace 1 Utilization: 1,546,336,002,048 [1.54 TB]
Namespace 1 Formatted LBA Size: 4096
Namespace 1 IEEE EUI-64: 00a075 ...
Local Time is: Thu Nov 17 00:25:52 2022 CET
Firmware Updates (0x17): 3 Slots, Slot 1 R/O, no Reset required
Optional Admin Commands (0x005e): Format Frmw_DL NS_Mngmt Self_Test MI_Snd/Rec
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 1024 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x16): NA_Fields Dea/Unw_Error NP_Fields
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.25W - - 0 0 0 0 0 0
1 + 7.50W - - 0 0 0 0 10 10
2 + 7.50W - - 0 0 0 0 10 10
3 + 7.50W - - 0 0 0 0 10 10
4 + 5.50W - - 0 0 0 0 10 10
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 - 512 0 2
1 + 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 45 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 60,537,121 [30.9 TB]
Data Units Written: 40,293,713 [20.6 TB]
Host Read Commands: 839,147,323
Host Write Commands: 1,234,305,202
Controller Busy Time: 2,256
Power Cycles: 162
Power On Hours: 4,478
Unsafe Shutdowns: 81
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,422
Warning Comp. Temperature Time: 1
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 56 Celsius
Temperature Sensor 2: 50 Celsius
Temperature Sensor 3: 38 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 1422 0 0x000a 0x8004 0x028 0 0 -
/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint T133
Device Model: SAMSUNG HD300LJ
Serial Number: --
Firmware Version: ZT100-13
User Capacity: 300,069,052,416 bytes [300 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
Local Time is: Thu Nov 17 00:25:52 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7040) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 127) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 253 100 051 - 0
3 Spin_Up_Time POS--- 100 100 015 - 8064
4 Start_Stop_Count -O--CK 100 100 000 - 472
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 43471
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 328
190 Airflow_Temperature_Cel -O---K 073 059 000 - 27
194 Temperature_Celsius -O---K 157 115 000 - 27
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 8934
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 100 000 - 0
198 Offline_Uncorrectable ----CK 253 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1
200 Multi_Zone_Error_Rate -O-R-- 253 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 100 000 - 75
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Invalid Error Log index = 0x0000, trying reserved byte (0x01) instead
Device Error Count: 1
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 [0] occurred at disk power-on lifetime: 37557 hours (1564 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 04 00 00 00 1d b7 42 42 e9 00
Error: ABRT 1024 sectors at LBA = 0x1db74242 = 498549314
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
35 00 00 04 00 00 00 1d b7 42 42 e9 00 45d+11:47:15.145 WRITE DMA EXT
35 00 00 04 00 00 00 1d b7 3e 42 e9 00 45d+11:47:15.145 WRITE DMA EXT
35 00 00 04 00 00 00 1d b7 3a 42 e9 00 45d+11:47:15.145 WRITE DMA EXT
35 00 00 04 00 00 00 1d b7 36 42 e9 00 45d+11:47:15.145 WRITE DMA EXT
35 00 00 04 00 00 00 1d b7 32 42 e9 00 45d+11:47:15.083 WRITE DMA EXT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 42797 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: --/28 Celsius
Lifetime Min/Max Temperature: --/43 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 10/55 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (46)
Index Estimated Time Temperature Celsius
47 2022-11-16 22:18 27 ********
... ..( 95 skipped). .. ********
15 2022-11-16 23:54 27 ********
16 2022-11-16 23:55 28 *********
17 2022-11-16 23:56 27 ********
18 2022-11-16 23:57 27 ********
19 2022-11-16 23:58 28 *********
20 2022-11-16 23:59 27 ********
21 2022-11-17 00:00 28 *********
22 2022-11-17 00:01 27 ********
... ..( 7 skipped). .. ********
30 2022-11-17 00:09 27 ********
31 2022-11-17 00:10 ? -
32 2022-11-17 00:11 28 *********
... ..( 6 skipped). .. *********
39 2022-11-17 00:18 28 *********
40 2022-11-17 00:19 27 ********
... ..( 5 skipped). .. ********
46 2022-11-17 00:25 27 ********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x8001 2 0 Vendor specific
/dev/sdb
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F3
Device Model: SAMSUNG HD103SJ
Serial Number: --
LU WWN Device Id: 5 0024e9 ...
Firmware Version: 1AJ10001
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Thu Nov 17 00:25:53 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9300) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 155) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 134
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 071 070 025 - 8869
4 Start_Stop_Count -O--CK 100 100 000 - 613
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 36610
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 528
191 G-Sense_Error_Rate -O---K 100 100 000 - 19
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 064 055 000 - 29 (Min/Max 17/45)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 252 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 4
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 394
223 Load_Retry_Count -O--CK 252 252 000 - 0
225 Load_Cycle_Count -O--CK 100 100 000 - 2671
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 4
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 4 [3] occurred at disk power-on lifetime: 29826 hours (1242 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 ab 28 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 43816 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 59 26 ab 20 e0 00 00:00:00.392 READ DMA EXT
25 00 03 00 08 00 00 59 26 aa f0 e0 00 00:00:00.392 READ DMA EXT
25 00 03 00 08 00 00 59 26 aa e0 e0 00 00:00:00.392 READ DMA EXT
25 00 03 00 08 00 00 59 26 aa d8 e0 00 00:00:00.392 READ DMA EXT
25 00 03 00 08 00 00 59 26 aa d0 e0 00 00:00:00.392 READ DMA EXT
Error 3 [2] occurred at disk power-on lifetime: 29826 hours (1242 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 95 30 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 38192 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 59 25 95 28 e0 00 00:00:00.061 READ DMA EXT
25 00 03 00 08 00 00 05 9f 86 00 e0 00 00:00:00.061 READ DMA EXT
25 00 03 00 08 00 00 59 25 95 68 e0 00 00:00:00.061 READ DMA EXT
35 00 03 00 08 00 00 00 62 c3 00 e0 00 00:00:00.061 WRITE DMA EXT
35 00 03 00 08 00 00 00 62 c2 d0 e0 00 00:00:00.061 WRITE DMA EXT
Error 2 [1] occurred at disk power-on lifetime: 29826 hours (1242 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 94 a0 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 38048 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 00 62 94 98 e0 00 00:00:00.058 READ DMA EXT
25 00 03 00 08 00 00 00 62 9c a8 e0 00 00:00:00.058 READ DMA EXT
25 00 03 00 08 00 00 00 62 9c 18 e0 00 00:00:00.058 READ DMA EXT
35 00 03 00 08 00 00 00 62 02 d8 e0 00 00:00:00.058 WRITE DMA EXT
25 00 03 00 08 00 00 04 86 93 a8 e0 00 00:00:00.058 READ DMA EXT
Error 1 [0] occurred at disk power-on lifetime: 29826 hours (1242 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 c0 90 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 49296 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 03 00 08 00 00 00 62 c0 88 e0 00 00:00:00.055 READ DMA EXT
25 00 03 00 08 00 00 05 88 c7 d8 e0 00 00:00:00.055 READ DMA EXT
25 00 03 00 08 00 00 00 62 bf f0 e0 00 00:00:00.055 READ DMA EXT
25 00 03 00 08 00 00 05 88 c7 d0 e0 00 00:00:00.055 READ DMA EXT
25 00 03 00 08 00 00 00 62 bf 98 e0 00 00:00:00.055 READ DMA EXT
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 30912 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 29/29 Celsius
Lifetime Min/Max Temperature: 21/68 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (111)
Index Estimated Time Temperature Celsius
112 2022-11-16 13:50 29 **********
... ..( 3 skipped). .. **********
116 2022-11-16 14:10 29 **********
117 2022-11-16 14:15 28 *********
118 2022-11-16 14:20 28 *********
119 2022-11-16 14:25 29 **********
120 2022-11-16 14:30 29 **********
121 2022-11-16 14:35 28 *********
... ..( 11 skipped). .. *********
5 2022-11-16 15:35 28 *********
6 2022-11-16 15:40 29 **********
7 2022-11-16 15:45 28 *********
8 2022-11-16 15:50 28 *********
9 2022-11-16 15:55 29 **********
10 2022-11-16 16:00 29 **********
11 2022-11-16 16:05 28 *********
... ..( 21 skipped). .. *********
33 2022-11-16 17:55 28 *********
34 2022-11-16 18:00 29 **********
... ..( 3 skipped). .. **********
38 2022-11-16 18:20 29 **********
39 2022-11-16 18:25 28 *********
... ..( 4 skipped). .. *********
44 2022-11-16 18:50 28 *********
45 2022-11-16 18:55 27 ********
46 2022-11-16 19:00 28 *********
... ..( 49 skipped). .. *********
96 2022-11-16 23:10 28 *********
97 2022-11-16 23:15 29 **********
98 2022-11-16 23:20 29 **********
99 2022-11-16 23:25 28 *********
100 2022-11-16 23:30 28 *********
101 2022-11-16 23:35 28 *********
102 2022-11-16 23:40 29 **********
... ..( 2 skipped). .. **********
105 2022-11-16 23:55 29 **********
106 2022-11-17 00:00 28 *********
107 2022-11-17 00:05 29 **********
... ..( 3 skipped). .. **********
111 2022-11-17 00:25 29 **********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific
/dev/sdc
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST18000NM000J-2TV103
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: SN02
User Capacity: 18,000,207,937,536 bytes [18.0 TB]
Sector Size: 4096 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-4 (minor revision not indicated)
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 17 00:25:54 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Disabled
DSN feature is: Disabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Unexpected SCT status 0x000d (action_code=0, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1042) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: (1534) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x70bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 083 064 044 - 25384289
3 Spin_Up_Time PO---- 090 089 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 200
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 089 060 045 - 888577564
9 Power_On_Hours -O--CK 093 093 000 - 6615
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 182
18 Unknown_Attribute PO-R-- 100 100 050 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 099 000 - 4295032833
190 Airflow_Temperature_Cel -O---K 061 049 000 - 39 (Min/Max 39/39)
192 Power-Off_Retract_Count -O--CK 100 100 000 - 97
193 Load_Cycle_Count -O--CK 097 097 000 - 7576
194 Temperature_Celsius -O---K 039 051 000 - 39 (0 20 0 0 0)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 2
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
240 Head_Flying_Hours ------ 100 253 000 - 5220 (112 152 0)
241 Total_LBAs_Written ------ 100 253 000 - 10192516229
242 Total_LBAs_Read ------ 100 253 000 - 254762052698873
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL R/O 256 Device Statistics log
0x04 SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0a GPL R/W 8 Device Statistics Notification
0x0c GPL R/O 2048 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 768 Current Device Internal Status Data log
0x2f GPL - 1 Set Sector Configuration
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 160 Device vendor specific log
0xa2 GPL VS 16320 Device vendor specific log
0xa4 GPL,SL VS 160 Device vendor specific log
0xa6 GPL VS 192 Device vendor specific log
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xad GPL VS 16 Device vendor specific log
0xb1 GPL,SL VS 160 Device vendor specific log
0xb6 GPL VS 1920 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc1 GPL,SL VS 8 Device vendor specific log
0xc3 GPL,SL VS 24 Device vendor specific log
0xc6 GPL VS 5184 Device vendor specific log
0xc7 GPL,SL VS 8 Device vendor specific log
0xc9 GPL,SL VS 8 Device vendor specific log
0xca GPL,SL VS 16 Device vendor specific log
0xcd GPL,SL VS 1 Device vendor specific log
0xce GPL VS 1 Device vendor specific log
0xcf GPL VS 512 Device vendor specific log
0xd1 GPL VS 656 Device vendor specific log
0xd2 GPL VS 10256 Device vendor specific log
0xd4 GPL VS 2048 Device vendor specific log
0xda GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 5910 -
# 2 Short offline Completed without error 00% 996 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 38/39 Celsius
Lifetime Min/Max Temperature: 20/51 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
Vendor specific:
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 4 minutes
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 10/40 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (29)
Index Estimated Time Temperature Celsius
30 2022-11-11 19:00 35 ****************
31 2022-11-11 19:59 36 *****************
... ..( 4 skipped). .. *****************
36 2022-11-12 00:54 36 *****************
37 2022-11-12 01:53 38 *******************
38 2022-11-12 02:52 37 ******************
39 2022-11-12 03:51 36 *****************
... ..( 3 skipped). .. *****************
43 2022-11-12 07:47 36 *****************
44 2022-11-12 08:46 37 ******************
45 2022-11-12 09:45 36 *****************
46 2022-11-12 10:44 35 ****************
47 2022-11-12 11:43 36 *****************
... ..( 2 skipped). .. *****************
50 2022-11-12 14:40 36 *****************
51 2022-11-12 15:39 37 ******************
52 2022-11-12 16:38 36 *****************
53 2022-11-12 17:37 36 *****************
54 2022-11-12 18:36 35 ****************
55 2022-11-12 19:35 36 *****************
... ..( 2 skipped). .. *****************
58 2022-11-12 22:32 36 *****************
59 2022-11-12 23:31 38 *******************
60 2022-11-13 00:30 38 *******************
61 2022-11-13 01:29 37 ******************
62 2022-11-13 02:28 36 *****************
63 2022-11-13 03:27 36 *****************
64 2022-11-13 04:26 35 ****************
65 2022-11-13 05:25 38 *******************
66 2022-11-13 06:24 38 *******************
67 2022-11-13 07:23 38 *******************
68 2022-11-13 08:22 35 ****************
69 2022-11-13 09:21 36 *****************
70 2022-11-13 10:20 36 *****************
71 2022-11-13 11:19 35 ****************
72 2022-11-13 12:18 38 *******************
73 2022-11-13 13:17 38 *******************
74 2022-11-13 14:16 36 *****************
75 2022-11-13 15:15 37 ******************
76 2022-11-13 16:14 38 *******************
77 2022-11-13 17:13 36 *****************
78 2022-11-13 18:12 35 ****************
79 2022-11-13 19:11 35 ****************
80 2022-11-13 20:10 36 *****************
81 2022-11-13 21:09 36 *****************
82 2022-11-13 22:08 38 *******************
83 2022-11-13 23:07 39 ********************
84 2022-11-14 00:06 36 *****************
85 2022-11-14 01:05 39 ********************
86 2022-11-14 02:04 36 *****************
87 2022-11-14 03:03 38 *******************
88 2022-11-14 04:02 36 *****************
89 2022-11-14 05:01 36 *****************
90 2022-11-14 06:00 35 ****************
91 2022-11-14 06:59 35 ****************
92 2022-11-14 07:58 36 *****************
93 2022-11-14 08:57 36 *****************
94 2022-11-14 09:56 35 ****************
95 2022-11-14 10:55 36 *****************
96 2022-11-14 11:54 35 ****************
97 2022-11-14 12:53 38 *******************
98 2022-11-14 13:52 ? -
99 2022-11-14 14:51 36 *****************
100 2022-11-14 15:50 38 *******************
101 2022-11-14 16:49 38 *******************
102 2022-11-14 17:48 39 ********************
103 2022-11-14 18:47 38 *******************
104 2022-11-14 19:46 38 *******************
105 2022-11-14 20:45 37 ******************
106 2022-11-14 21:44 37 ******************
107 2022-11-14 22:43 38 *******************
108 2022-11-14 23:42 38 *******************
109 2022-11-15 00:41 38 *******************
110 2022-11-15 01:40 39 ********************
111 2022-11-15 02:39 38 *******************
112 2022-11-15 03:38 38 *******************
113 2022-11-15 04:37 38 *******************
114 2022-11-15 05:36 37 ******************
115 2022-11-15 06:35 37 ******************
116 2022-11-15 07:34 37 ******************
117 2022-11-15 08:33 38 *******************
118 2022-11-15 09:32 38 *******************
119 2022-11-15 10:31 37 ******************
120 2022-11-15 11:30 37 ******************
121 2022-11-15 12:29 37 ******************
122 2022-11-15 13:28 38 *******************
123 2022-11-15 14:27 39 ********************
124 2022-11-15 15:26 39 ********************
125 2022-11-15 16:25 38 *******************
126 2022-11-15 17:24 39 ********************
127 2022-11-15 18:23 39 ********************
0 2022-11-15 19:22 40 *********************
1 2022-11-15 20:21 39 ********************
2 2022-11-15 21:20 38 *******************
... ..( 2 skipped). .. *******************
5 2022-11-16 00:17 38 *******************
6 2022-11-16 01:16 40 *********************
7 2022-11-16 02:15 38 *******************
... ..( 3 skipped). .. *******************
11 2022-11-16 06:11 38 *******************
12 2022-11-16 07:10 39 ********************
13 2022-11-16 08:09 38 *******************
... ..( 2 skipped). .. *******************
16 2022-11-16 11:06 38 *******************
17 2022-11-16 12:05 39 ********************
18 2022-11-16 13:04 38 *******************
19 2022-11-16 14:03 39 ********************
20 2022-11-16 15:02 38 *******************
21 2022-11-16 16:01 38 *******************
22 2022-11-16 17:00 39 ********************
23 2022-11-16 17:59 38 *******************
... ..( 3 skipped). .. *******************
27 2022-11-16 21:55 38 *******************
28 2022-11-16 22:54 ? -
29 2022-11-16 23:53 39 ********************
SCT Error Recovery Control:
Read: 100 (10.0 seconds)
Write: 100 (10.0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 182 --- Lifetime Power-On Resets
0x01 0x010 4 6615 --- Power-on Hours
0x01 0x018 6 10177097508 --- Logical Sectors Written
0x01 0x020 6 99143339 --- Number of Write Commands
0x01 0x028 6 253275399400296 --- Logical Sectors Read
0x01 0x030 6 5982181078 --- Number of Read Commands
0x01 0x038 6 1668641152649 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 6597 --- Spindle Motor Power-on Hours
0x03 0x010 4 5471 --- Head Flying Hours
0x03 0x018 4 7576 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
0x03 0x040 4 97 --- Number of High Priority Unload Events
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
0x04 0x018 4 0 -D- Physical Element Status Changed
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 39 --- Current Temperature
0x05 0x010 1 38 --- Average Short Term Temperature
0x05 0x018 1 35 --- Average Long Term Temperature
0x05 0x020 1 51 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x030 1 43 --- Highest Average Short Term Temperature
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
0x05 0x040 1 38 --- Highest Average Long Term Temperature
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2075 --- Number of Hardware Resets
0x06 0x010 4 906 --- Number of ASR Events
0x06 0x018 4 2 --- Number of Interface CRC Errors
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
0xff 0x008 7 0 --- Vendor Specific
0xff 0x010 7 0 --- Vendor Specific
0xff 0x018 7 0 --- Vendor Specific
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c)
No Defects Logged
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/sdd
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Ultrastar DC HC550
Device Model: WDC WUH721818ALE6L4
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: PCGNW232
User Capacity: 18,000,207,937,536 bytes [18.0 TB]
Sector Size: 4096 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 published, ANSI INCITS 529-2018
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 17 00:25:54 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Disabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 101) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: (1788) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 001 - 0
2 Throughput_Performance P-S--- 136 136 054 - 96
3 Spin_Up_Time POS--- 082 082 001 - 362 (Average 362)
4 Start_Stop_Count -O--C- 100 100 000 - 176
5 Reallocated_Sector_Ct PO--CK 100 100 001 - 0
7 Seek_Error_Rate PO-R-- 100 100 001 - 0
8 Seek_Time_Performance P-S--- 140 140 020 - 15
9 Power_On_Hours -O--C- 100 100 000 - 5781
10 Spin_Retry_Count PO--C- 100 100 001 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 164
22 Helium_Level PO---K 100 100 025 - 100
192 Power-Off_Retract_Count -O--CK 100 100 000 - 4043
193 Load_Cycle_Count -O--C- 100 100 000 - 4043
194 Temperature_Celsius -O---- 058 058 000 - 36 (Min/Max 24/46)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 256 Device Statistics log
0x04 SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0c GPL R/O 3751 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x12 GPL R/O 1 SATA NCQ Non-Data log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x15 GPL R/W 1 Rebuild Assist log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 256 Current Device Internal Status Data log
0x25 GPL R/O 256 Saved Device Internal Status Data log
0x2f GPL - 1 Set Sector Configuration
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 2236 -
# 2 Short offline Completed without error 00% 62 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 35/36 Celsius
Lifetime Min/Max Temperature: 24/46 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
Minimum supported ERC Time Limit: 65 (6.5 seconds)
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (64)
Index Estimated Time Temperature Celsius
65 2022-11-16 22:18 35 ****************
... ..( 2 skipped). .. ****************
68 2022-11-16 22:21 35 ****************
69 2022-11-16 22:22 36 *****************
70 2022-11-16 22:23 36 *****************
71 2022-11-16 22:24 35 ****************
72 2022-11-16 22:25 36 *****************
... ..( 15 skipped). .. *****************
88 2022-11-16 22:41 36 *****************
89 2022-11-16 22:42 35 ****************
... ..( 7 skipped). .. ****************
97 2022-11-16 22:50 35 ****************
98 2022-11-16 22:51 36 *****************
... ..( 2 skipped). .. *****************
101 2022-11-16 22:54 36 *****************
102 2022-11-16 22:55 35 ****************
... ..( 14 skipped). .. ****************
117 2022-11-16 23:10 35 ****************
118 2022-11-16 23:11 34 ***************
119 2022-11-16 23:12 35 ****************
120 2022-11-16 23:13 35 ****************
121 2022-11-16 23:14 34 ***************
122 2022-11-16 23:15 34 ***************
123 2022-11-16 23:16 35 ****************
124 2022-11-16 23:17 34 ***************
... ..( 34 skipped). .. ***************
31 2022-11-16 23:52 34 ***************
32 2022-11-16 23:53 35 ****************
... ..( 4 skipped). .. ****************
37 2022-11-16 23:58 35 ****************
38 2022-11-16 23:59 36 *****************
... ..( 24 skipped). .. *****************
63 2022-11-17 00:24 36 *****************
64 2022-11-17 00:25 35 ****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 164 --- Lifetime Power-On Resets
0x01 0x010 4 5781 --- Power-on Hours
0x01 0x018 6 9325823874 --- Logical Sectors Written
0x01 0x020 6 87000027 --- Number of Write Commands
0x01 0x028 6 84583938201 --- Logical Sectors Read
0x01 0x030 6 6137535310 --- Number of Read Commands
0x01 0x038 6 1668641153150 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 5307 --- Spindle Motor Power-on Hours
0x03 0x010 4 5307 --- Head Flying Hours
0x03 0x018 4 4043 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 34 N-- Average Short Term Temperature
0x05 0x018 1 34 N-- Average Long Term Temperature
0x05 0x020 1 46 --- Highest Temperature
0x05 0x028 1 24 --- Lowest Temperature
0x05 0x030 1 41 N-- Highest Average Short Term Temperature
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
0x05 0x040 1 36 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1963 --- Number of Hardware Resets
0x06 0x010 4 731 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c)
No Defects Logged
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdf
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Ultrastar DC HC550
Device Model: WDC WUH721818ALE6L4
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: PCGNW232
User Capacity: 18,000,207,937,536 bytes [18.0 TB]
Sector Size: 4096 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-4 published, ANSI INCITS 529-2018
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 17 00:25:56 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Disabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 101) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: (1963) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 001 - 0
2 Throughput_Performance P-S--- 136 136 054 - 96
3 Spin_Up_Time POS--- 083 083 001 - 355 (Average 357)
4 Start_Stop_Count -O--C- 100 100 000 - 199
5 Reallocated_Sector_Ct PO--CK 100 100 001 - 0
7 Seek_Error_Rate PO-R-- 100 100 001 - 0
8 Seek_Time_Performance P-S--- 140 140 020 - 15
9 Power_On_Hours -O--C- 100 100 000 - 6743
10 Spin_Retry_Count PO--C- 100 100 001 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 184
22 Helium_Level PO---K 100 100 025 - 100
192 Power-Off_Retract_Count -O--CK 100 100 000 - 5447
193 Load_Cycle_Count -O--C- 100 100 000 - 5447
194 Temperature_Celsius -O---- 060 060 000 - 34 (Min/Max 19/47)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL R/O 256 Device Statistics log
0x04 SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0c GPL R/O 3751 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x12 GPL R/O 1 SATA NCQ Non-Data log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x15 GPL R/W 1 Rebuild Assist log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 256 Current Device Internal Status Data log
0x25 GPL R/O 256 Saved Device Internal Status Data log
0x2f GPL - 1 Set Sector Configuration
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 6071 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 33/34 Celsius
Lifetime Min/Max Temperature: 19/47 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
Minimum supported ERC Time Limit: 65 (6.5 seconds)
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (41)
Index Estimated Time Temperature Celsius
42 2022-11-16 22:18 33 **************
... ..( 2 skipped). .. **************
45 2022-11-16 22:21 33 **************
46 2022-11-16 22:22 34 ***************
... ..( 25 skipped). .. ***************
72 2022-11-16 22:48 34 ***************
73 2022-11-16 22:49 33 **************
74 2022-11-16 22:50 34 ***************
... ..( 9 skipped). .. ***************
84 2022-11-16 23:00 34 ***************
85 2022-11-16 23:01 33 **************
... ..( 52 skipped). .. **************
10 2022-11-16 23:54 33 **************
11 2022-11-16 23:55 34 ***************
... ..( 9 skipped). .. ***************
21 2022-11-17 00:05 34 ***************
22 2022-11-17 00:06 35 ****************
23 2022-11-17 00:07 34 ***************
... ..( 16 skipped). .. ***************
40 2022-11-17 00:24 34 ***************
41 2022-11-17 00:25 33 **************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 184 --- Lifetime Power-On Resets
0x01 0x010 4 6743 --- Power-on Hours
0x01 0x018 6 12898946411 --- Logical Sectors Written
0x01 0x020 6 177036946 --- Number of Write Commands
0x01 0x028 6 106826101436 --- Logical Sectors Read
0x01 0x030 6 6985804550 --- Number of Read Commands
0x01 0x038 6 1668641154500 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 6084 --- Spindle Motor Power-on Hours
0x03 0x010 4 6084 --- Head Flying Hours
0x03 0x018 4 5447 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 34 --- Current Temperature
0x05 0x010 1 33 N-- Average Short Term Temperature
0x05 0x018 1 32 N-- Average Long Term Temperature
0x05 0x020 1 47 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 41 N-- Highest Average Short Term Temperature
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
0x05 0x040 1 36 N-- Highest Average Long Term Temperature
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2712 --- Number of Hardware Resets
0x06 0x010 4 1002 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c)
No Defects Logged
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdg
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST18000NM000J-2TV103
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: SN02
User Capacity: 18,000,207,937,536 bytes [18.0 TB]
Sector Size: 4096 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-4 (minor revision not indicated)
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Nov 17 00:25:56 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Disabled
DSN feature is: Disabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Unexpected SCT status 0x000d (action_code=0, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1009) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: (1543) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x70bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 069 064 044 - 1026806
3 Spin_Up_Time PO---- 089 089 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 199
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 090 060 045 - 917625373
9 Power_On_Hours -O--CK 093 093 000 - 6741
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 180
18 Unknown_Attribute PO-R-- 100 100 050 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 099 000 - 4295032833
190 Airflow_Temperature_Cel -O---K 064 048 000 - 36 (Min/Max 36/37)
192 Power-Off_Retract_Count -O--CK 100 100 000 - 98
193 Load_Cycle_Count -O--CK 097 097 000 - 7408
194 Temperature_Celsius -O---K 036 049 000 - 36 (0 20 0 0 0)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
240 Head_Flying_Hours ------ 100 253 000 - 5382 (167 212 0)
241 Total_LBAs_Written ------ 100 253 000 - 12837760256
242 Total_LBAs_Read ------ 100 253 000 - 4014138316446
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL R/O 256 Device Statistics log
0x04 SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x0a GPL R/W 8 Device Statistics Notification
0x0c GPL R/O 2048 Pending Defects log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x24 GPL R/O 768 Current Device Internal Status Data log
0x2f GPL - 1 Set Sector Configuration
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 160 Device vendor specific log
0xa2 GPL VS 16320 Device vendor specific log
0xa4 GPL,SL VS 160 Device vendor specific log
0xa6 GPL VS 192 Device vendor specific log
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xad GPL VS 16 Device vendor specific log
0xb1 GPL,SL VS 160 Device vendor specific log
0xb6 GPL VS 1920 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc1 GPL,SL VS 8 Device vendor specific log
0xc3 GPL,SL VS 24 Device vendor specific log
0xc6 GPL VS 5184 Device vendor specific log
0xc7 GPL,SL VS 8 Device vendor specific log
0xc9 GPL,SL VS 8 Device vendor specific log
0xca GPL,SL VS 16 Device vendor specific log
0xcd GPL,SL VS 1 Device vendor specific log
0xce GPL VS 1 Device vendor specific log
0xcf GPL VS 512 Device vendor specific log
0xd1 GPL VS 656 Device vendor specific log
0xd2 GPL VS 10256 Device vendor specific log
0xd4 GPL VS 2048 Device vendor specific log
0xda GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 6039 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 35/37 Celsius
Lifetime Min/Max Temperature: 20/51 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
Vendor specific:
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 4 minutes
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 10/40 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (25)
Index Estimated Time Temperature Celsius
26 2022-11-11 19:00 33 **************
... ..( 2 skipped). .. **************
29 2022-11-11 21:57 33 **************
30 2022-11-11 22:56 34 ***************
31 2022-11-11 23:55 35 ****************
32 2022-11-12 00:54 34 ***************
33 2022-11-12 01:53 34 ***************
34 2022-11-12 02:52 34 ***************
35 2022-11-12 03:51 33 **************
36 2022-11-12 04:50 35 ****************
37 2022-11-12 05:49 34 ***************
38 2022-11-12 06:48 33 **************
39 2022-11-12 07:47 34 ***************
40 2022-11-12 08:46 34 ***************
41 2022-11-12 09:45 33 **************
42 2022-11-12 10:44 33 **************
43 2022-11-12 11:43 33 **************
44 2022-11-12 12:42 34 ***************
45 2022-11-12 13:41 33 **************
46 2022-11-12 14:40 34 ***************
47 2022-11-12 15:39 34 ***************
48 2022-11-12 16:38 33 **************
49 2022-11-12 17:37 33 **************
50 2022-11-12 18:36 33 **************
51 2022-11-12 19:35 34 ***************
52 2022-11-12 20:34 34 ***************
53 2022-11-12 21:33 33 **************
54 2022-11-12 22:32 33 **************
55 2022-11-12 23:31 36 *****************
56 2022-11-13 00:30 35 ****************
... ..( 2 skipped). .. ****************
59 2022-11-13 03:27 35 ****************
60 2022-11-13 04:26 36 *****************
61 2022-11-13 05:25 35 ****************
62 2022-11-13 06:24 34 ***************
63 2022-11-13 07:23 35 ****************
64 2022-11-13 08:22 33 **************
65 2022-11-13 09:21 33 **************
66 2022-11-13 10:20 34 ***************
67 2022-11-13 11:19 35 ****************
68 2022-11-13 12:18 34 ***************
69 2022-11-13 13:17 34 ***************
70 2022-11-13 14:16 33 **************
71 2022-11-13 15:15 36 *****************
72 2022-11-13 16:14 35 ****************
73 2022-11-13 17:13 33 **************
74 2022-11-13 18:12 33 **************
75 2022-11-13 19:11 35 ****************
76 2022-11-13 20:10 33 **************
77 2022-11-13 21:09 35 ****************
78 2022-11-13 22:08 34 ***************
79 2022-11-13 23:07 36 *****************
80 2022-11-14 00:06 33 **************
81 2022-11-14 01:05 36 *****************
82 2022-11-14 02:04 33 **************
83 2022-11-14 03:03 34 ***************
84 2022-11-14 04:02 34 ***************
85 2022-11-14 05:01 33 **************
... ..( 4 skipped). .. **************
90 2022-11-14 09:56 33 **************
91 2022-11-14 10:55 34 ***************
92 2022-11-14 11:54 33 **************
93 2022-11-14 12:53 35 ****************
94 2022-11-14 13:52 ? -
95 2022-11-14 14:51 33 **************
96 2022-11-14 15:50 37 ******************
97 2022-11-14 16:49 35 ****************
... ..( 2 skipped). .. ****************
100 2022-11-14 19:46 35 ****************
101 2022-11-14 20:45 34 ***************
102 2022-11-14 21:44 35 ****************
... ..( 3 skipped). .. ****************
106 2022-11-15 01:40 35 ****************
107 2022-11-15 02:39 34 ***************
108 2022-11-15 03:38 35 ****************
109 2022-11-15 04:37 35 ****************
110 2022-11-15 05:36 34 ***************
111 2022-11-15 06:35 35 ****************
112 2022-11-15 07:34 34 ***************
113 2022-11-15 08:33 35 ****************
114 2022-11-15 09:32 36 *****************
115 2022-11-15 10:31 35 ****************
116 2022-11-15 11:30 34 ***************
117 2022-11-15 12:29 34 ***************
118 2022-11-15 13:28 35 ****************
119 2022-11-15 14:27 36 *****************
120 2022-11-15 15:26 36 *****************
121 2022-11-15 16:25 35 ****************
122 2022-11-15 17:24 35 ****************
123 2022-11-15 18:23 35 ****************
124 2022-11-15 19:22 36 *****************
125 2022-11-15 20:21 37 ******************
126 2022-11-15 21:20 35 ****************
127 2022-11-15 22:19 35 ****************
0 2022-11-15 23:18 35 ****************
1 2022-11-16 00:17 36 *****************
2 2022-11-16 01:16 37 ******************
3 2022-11-16 02:15 35 ****************
... ..( 3 skipped). .. ****************
7 2022-11-16 06:11 35 ****************
8 2022-11-16 07:10 36 *****************
9 2022-11-16 08:09 35 ****************
... ..( 2 skipped). .. ****************
12 2022-11-16 11:06 35 ****************
13 2022-11-16 12:05 36 *****************
14 2022-11-16 13:04 35 ****************
15 2022-11-16 14:03 36 *****************
16 2022-11-16 15:02 36 *****************
17 2022-11-16 16:01 35 ****************
18 2022-11-16 17:00 35 ****************
19 2022-11-16 17:59 35 ****************
20 2022-11-16 18:58 34 ***************
21 2022-11-16 19:57 34 ***************
22 2022-11-16 20:56 36 *****************
23 2022-11-16 21:55 35 ****************
24 2022-11-16 22:54 ? -
25 2022-11-16 23:53 36 *****************
SCT Error Recovery Control:
Read: 100 (10.0 seconds)
Write: 100 (10.0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 180 --- Lifetime Power-On Resets
0x01 0x010 4 6741 --- Power-on Hours
0x01 0x018 6 12817489768 --- Logical Sectors Written
0x01 0x020 6 178831620 --- Number of Write Commands
0x01 0x028 6 3618394779564 --- Logical Sectors Read
0x01 0x030 6 5503035200 --- Number of Read Commands
0x01 0x038 6 1668641155474 --- Date and Time TimeStamp
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 6722 --- Spindle Motor Power-on Hours
0x03 0x010 4 5629 --- Head Flying Hours
0x03 0x018 4 7408 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
0x03 0x040 4 98 --- Number of High Priority Unload Events
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
0x04 0x018 4 0 -D- Physical Element Status Changed
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 35 --- Average Short Term Temperature
0x05 0x018 1 33 --- Average Long Term Temperature
0x05 0x020 1 49 --- Highest Temperature
0x05 0x028 1 23 --- Lowest Temperature
0x05 0x030 1 42 --- Highest Average Short Term Temperature
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
0x05 0x040 1 36 --- Highest Average Long Term Temperature
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2292 --- Number of Hardware Resets
0x06 0x010 4 978 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
0xff 0x008 7 0 --- Vendor Specific
0xff 0x010 7 0 --- Vendor Specific
0xff 0x018 7 0 --- Vendor Specific
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c)
No Defects Logged
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/sdh
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: NVME
Product: INTEL SSDPF21Q80
Revision: 0200
Compliance: SPC-4
User Capacity: 800,166,076,416 bytes [800 GB]
Logical block size: 512 bytes
LU is resource provisioned, LBPRZ=0
Rotation Rate: Solid State Device
Logical Unit id: 0x5cd2e4abd7530500
Serial number: --
Device type: disk
Local Time is: Thu Nov 17 00:25:57 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Disabled or Not Supported
Read Cache is: Unavailable
Writeback Cache is: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Percentage used endurance indicator: 0%
Current Drive Temperature: 33 C
Drive Trip Temperature: 70 C
Error Counter logging not supported
[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
Self-test Log Sense length is 0x9001 not 0x190 bytes
Background scan results log
Status: no scans active
Accumulated power on time, hours:minutes 295:00 [17700 minutes]
Number of background scans performed: 0, scan progress: 0.00%
Number of background medium scans performed: 0
/dev/sdi
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: NVME
Product: INTEL SSDPF21Q40
Revision: 0200
Compliance: SPC-4
User Capacity: 400,088,457,216 bytes [400 GB]
Logical block size: 512 bytes
LU is resource provisioned, LBPRZ=0
Rotation Rate: Solid State Device
Logical Unit id: 0x5cd2e439fb210500
Serial number: --
Device type: disk
Local Time is: Thu Nov 17 00:25:57 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Disabled or Not Supported
Read Cache is: Unavailable
Writeback Cache is: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Percentage used endurance indicator: 0%
Current Drive Temperature: 32 C
Drive Trip Temperature: 70 C
Error Counter logging not supported
[GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on']
Self-test Log Sense length is 0x9001 not 0x190 bytes
Background scan results log
Status: no scans active
Accumulated power on time, hours:minutes 3655:00 [219300 minutes]
Number of background scans performed: 0, scan progress: 0.00%
Number of background medium scans performed: 0
/dev/sg10
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.16.12] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: Adaptec
Product: 1200P-32i
Revision: 0114
Compliance: SPC-3
Serial number: --
Device type: storage array
Local Time is: Thu Nov 17 00:25:57 2022 CET
SMART support is: Unavailable - device lacks SMART capability.
=== START OF READ SMART DATA SECTION ===
Current Drive Temperature: 0 C
Drive Trip Temperature: 0 C
Error Counter logging not supported
Device does not support Self Test logging