/dev/sda
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-21-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: ADATA SP900
Serial Number: --
LU WWN Device Id: 5 707c18 ...
Firmware Version: 5.0.7b
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Aug 18 15:54:15 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 107 107 050 - 0/15386777
5 Retired_Block_Count PO--CK 100 100 003 - 2
9 Power_On_Hours_and_Msec -O--CK 040 040 000 - 53130h+28m+36.320s
12 Power_Cycle_Count -O--CK 100 100 000 - 677
171 Program_Fail_Count -O--CK 000 000 000 - 1
172 Erase_Fail_Count -O--CK 000 000 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 123
177 Wear_Range_Delta ------ 000 000 000 - 7
181 Program_Fail_Count -O--CK 000 000 000 - 1
182 Erase_Fail_Count -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 045 063 000 - 45 (Min/Max 14/63)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/15386777
196 Reallocated_Event_Count PO--CK 100 100 003 - 2
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/15386777
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/15386777
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 097 097 010 - 0
233 SandForce_Internal ------ 000 000 000 - 54586
234 SandForce_Internal -O--CK 000 000 000 - 52962
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 52962
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 15146
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x04 GPL,SL R/O 1 Device Statistics log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: 28/45 Celsius
Lifetime Min/Max Temperature: 14/63 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 10 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: -77/117 Celsius
Min/Max Temperature Limit: 18/-14 Celsius
Temperature History Size (Index): 41788 (58)
Invalid Temperature History Size or Index
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 677 --- Lifetime Power-On Resets
0x01 0x010 4 53130 --- Power-on Hours
0x01 0x018 6 111070655391 --- Logical Sectors Written
0x01 0x028 6 31763628565 --- Logical Sectors Read
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 4744 --- Resets Between Cmd Acceptance and Completion
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4744 --- Number of Hardware Resets
0x06 0x010 4 4161 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 255 --- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
/dev/sdb
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-21-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST500LM012 HN-M500MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2BA30001
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Aug 18 15:54:15 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 6540) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 109) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 12
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 094 090 025 - 2054
4 Start_Stop_Count -O--CK 098 098 000 - 2044
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 29218
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 5
12 Power_Cycle_Count -O--CK 098 098 000 - 2763
191 G-Sense_Error_Rate -O---K 100 100 000 - 2
192 Power-Off_Retract_Count -O---K 100 100 000 - 415
194 Temperature_Celsius -O---- 063 054 000 - 37 (Min/Max 13/46)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 252 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 25
223 Load_Retry_Count -O--CK 100 100 000 - 5
225 Load_Cycle_Count -O--CK 023 023 000 - 783319
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 23/37 Celsius
Lifetime Min/Max Temperature: 13/46 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (48)
Index Estimated Time Temperature Celsius
49 2022-08-18 05:15 37 ******************
50 2022-08-18 05:20 33 **************
... ..( 8 skipped). .. **************
59 2022-08-18 06:05 33 **************
60 2022-08-18 06:10 32 *************
... ..( 4 skipped). .. *************
65 2022-08-18 06:35 32 *************
66 2022-08-18 06:40 31 ************
... ..( 7 skipped). .. ************
74 2022-08-18 07:20 31 ************
75 2022-08-18 07:25 30 ***********
76 2022-08-18 07:30 30 ***********
77 2022-08-18 07:35 29 **********
78 2022-08-18 07:40 29 **********
79 2022-08-18 07:45 29 **********
80 2022-08-18 07:50 28 *********
... ..( 2 skipped). .. *********
83 2022-08-18 08:05 28 *********
84 2022-08-18 08:10 29 **********
85 2022-08-18 08:15 29 **********
86 2022-08-18 08:20 29 **********
87 2022-08-18 08:25 30 ***********
... ..( 4 skipped). .. ***********
92 2022-08-18 08:50 30 ***********
93 2022-08-18 08:55 31 ************
... ..( 30 skipped). .. ************
124 2022-08-18 11:30 31 ************
125 2022-08-18 11:35 30 ***********
... ..( 2 skipped). .. ***********
0 2022-08-18 11:50 30 ***********
1 2022-08-18 11:55 29 **********
2 2022-08-18 12:00 29 **********
3 2022-08-18 12:05 29 **********
4 2022-08-18 12:10 30 ***********
5 2022-08-18 12:15 30 ***********
6 2022-08-18 12:20 31 ************
7 2022-08-18 12:25 31 ************
8 2022-08-18 12:30 32 *************
9 2022-08-18 12:35 32 *************
10 2022-08-18 12:40 32 *************
11 2022-08-18 12:45 33 **************
... ..( 2 skipped). .. **************
14 2022-08-18 13:00 33 **************
15 2022-08-18 13:05 34 ***************
... ..( 4 skipped). .. ***************
20 2022-08-18 13:30 34 ***************
21 2022-08-18 13:35 35 ****************
... ..( 7 skipped). .. ****************
29 2022-08-18 14:15 35 ****************
30 2022-08-18 14:20 36 *****************
... ..( 10 skipped). .. *****************
41 2022-08-18 15:15 36 *****************
42 2022-08-18 15:20 37 ******************
... ..( 5 skipped). .. ******************
48 2022-08-18 15:50 37 ******************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 1290 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific