Probe #bf81a4069a of Acer Aspire TC-391 Desktop Computer
Log: smartctl
/dev/nvme0n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.74-generic-2rosa2021.1-x86_64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KINGSTON RBUSNS8154P3256GJ1
Serial Number: --
Firmware Version: E8FK12.3
PCI Vendor/Subsystem ID: 0x2646
IEEE OUI Identifier: 0x0026b7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0026b7 ...
Local Time is: Tue Jan 25 04:29:39 2022 MSK
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x001e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x04): Ext_Get_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.90W 0.0790W - 0 0 0 0 600 600
1 + 7.90W 0.0790W - 0 0 0 0 600 600
2 + 7.90W 0.0790W - 0 0 0 0 600 600
3 - 0.1000W 0.0790W - 3 3 3 3 1000 1000
4 - 0.0050W 0.0790W - 4 4 4 4 400000 90000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 100%
Percentage Used: 0%
Data Units Read: 3,277,296 [1.67 TB]
Data Units Written: 3,094,101 [1.58 TB]
Host Read Commands: 34,176,956
Host Write Commands: 30,231,869
Controller Busy Time: 108
Power Cycles: 144
Power On Hours: 301
Unsafe Shutdowns: 18
Media and Data Integrity Errors: 0
Error Information Log Entries: 74
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 2: 37 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 74 0 0x0002 0x0005 - 208 0 -
1 73 0 0x0002 0x0005 - 208 0 -
2 72 0 0x0002 0x0005 - 208 0 -
3 71 0 0x0002 0x0005 - 208 0 -
4 70 0 0x0002 0x0005 - 208 0 -
5 69 0 0x0007 0x0005 - 33555456 0 -
6 68 0 0x0007 0x0005 - 33555456 0 -
7 67 0 0x0002 0x0005 - 208 0 -
8 66 0 0x0007 0x0005 - 33555456 0 -
9 65 0 0x0007 0x0005 - 33555456 0 -
10 64 0 0x0002 0x0005 - 208 0 -
11 63 0 0x0002 0x0005 - 208 0 -
12 62 0 0x0002 0x0005 - 208 0 -
13 61 0 0x0002 0x0005 - 208 0 -
14 60 0 0x0002 0x0005 - 208 0 -
15 59 0 0x0002 0x0005 - 208 0 -