Probe #c0e37c70b7 of Sony VPCSA2V9R
Log: smartctl
/dev/sda
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA THNSNC128GMMJ
Serial Number: --
Firmware Version: CJSA0201
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 1.8 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Jan 24 22:38:56 2020 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 12) minutes.
SCT capabilities: (0x0039) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O-R-- 099 099 000 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--- 100 100 050 - 0
5 Reallocated_Sector_Ct PO--C- 100 100 050 - 0
7 Unknown_SSD_Attribute PO-R-- 100 100 050 - 0
8 Unknown_SSD_Attribute P-S--- 100 100 050 - 0
9 Power_On_Hours -O--C- 100 100 000 - 10214
10 Unknown_SSD_Attribute PO--C- 100 100 050 - 0
12 Power_Cycle_Count -O--C- 100 100 000 - 11744
167 Unknown_Attribute -O---K 100 100 000 - 0
168 Unknown_Attribute -O--C- 100 100 000 - 0
169 Unknown_Attribute PO--C- 100 100 010 - 287857837354
170 Unknown_Attribute PO--C- 100 100 010 - 38671220818
173 Unknown_Attribute -O--C- 100 100 000 - 4309516405
175 Program_Fail_Count_Chip PO--C- 100 100 010 - 0
192 Power-Off_Retract_Count -O--C- 100 100 000 - 72
194 Temperature_Celsius PO---K 064 051 030 - 36 (Min/Max 22/49)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
240 Unknown_SSD_Attribute PO--C- 100 100 050 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
SCT Support Level: 0
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 31/40 Celsius
Lifetime Min/Max Temperature: 22/49 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
00 00 04 00 01 01 00 05 05 00 00 00 00 00 00 00
00 02 01 00 1d 20 31 02 04 00 00 00 00 00 00 03
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/40 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (74)
Index Estimated Time Temperature Celsius
75 2020-01-24 20:31 36 *****************
... ..( 18 skipped). .. *****************
94 2020-01-24 20:50 36 *****************
95 2020-01-24 20:51 37 ******************
... ..( 3 skipped). .. ******************
99 2020-01-24 20:55 37 ******************
100 2020-01-24 20:56 36 *****************
101 2020-01-24 20:57 37 ******************
... ..( 6 skipped). .. ******************
108 2020-01-24 21:04 37 ******************
109 2020-01-24 21:05 36 *****************
110 2020-01-24 21:06 37 ******************
111 2020-01-24 21:07 37 ******************
112 2020-01-24 21:08 36 *****************
... ..( 34 skipped). .. *****************
19 2020-01-24 21:43 36 *****************
20 2020-01-24 21:44 35 ****************
... ..( 28 skipped). .. ****************
49 2020-01-24 22:13 35 ****************
50 2020-01-24 22:14 36 *****************
... ..( 17 skipped). .. *****************
68 2020-01-24 22:32 36 *****************
69 2020-01-24 22:33 37 ******************
70 2020-01-24 22:34 36 *****************
... ..( 3 skipped). .. *****************
74 2020-01-24 22:38 36 *****************
SCT Error Recovery Control:
Read: 80 (8.0 seconds)
Write: 80 (8.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 4 431380 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC