/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD2500BEVT-60A23T0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 02.01A02
User Capacity: 250 059 350 016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Feb 19 01:13:56 2017 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 41) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 6360) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 77) minutes.
SCT capabilities: (0x703f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 155 142 021 - 1250
4 Start_Stop_Count -O--CK 099 099 000 - 1926
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 097 097 000 - 2767
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1874
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 099 000 - 2
188 Command_Timeout -O--CK 100 099 000 - 4295098373
190 Airflow_Temperature_Cel -O---K 059 036 040 Past 41 (Min/Max 31/41 #11)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 605
192 Power-Off_Retract_Count -O--CK 200 200 000 - 264
193 Load_Cycle_Count -O--CK 103 103 000 - 292401
194 Temperature_Celsius -O---K 102 079 000 - 41
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 1438 hours (59 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 20 00 00 00 68 5f 28 40 00 Error: IDNF at LBA = 0x00685f28 = 6840104
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 00 00 00 06 cd 79 d8 40 00 01:24:43.562 READ FPDMA QUEUED
61 00 20 00 f8 00 00 00 68 5f 28 40 00 01:24:41.738 WRITE FPDMA QUEUED
61 00 08 00 f0 00 00 00 49 41 40 40 00 01:24:41.177 WRITE FPDMA QUEUED
61 00 20 00 e8 00 00 03 8e f0 50 40 00 01:24:38.614 WRITE FPDMA QUEUED
61 00 08 00 e0 00 00 00 4c 1b 00 40 00 01:24:38.613 WRITE FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 1212 hours (50 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 00 47 3f ea 40 00
Error: UNC at LBA = 0x00473fea = 4669418
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 40 00 30 00 00 00 47 3f ea 40 00 00:11:41.865 READ FPDMA QUEUED
60 00 20 00 28 00 00 00 47 5d 42 40 00 00:11:39.553 READ FPDMA QUEUED
60 00 20 00 20 00 00 00 70 67 d9 40 00 00:11:39.542 READ FPDMA QUEUED
60 00 20 00 18 00 00 00 70 68 59 40 00 00:11:39.520 READ FPDMA QUEUED
60 00 08 00 10 00 00 00 70 13 92 40 00 00:11:39.499 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Interrupted (host reset) 90% 2428 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 31/41 Celsius
Lifetime Min/Max Temperature: ?/64 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (41)
Index Estimated Time Temperature Celsius
42 2017-02-18 23:06 36 *****************
43 2017-02-18 23:07 37 ******************
44 2017-02-18 23:08 36 *****************
... ..( 3 skipped). .. *****************
48 2017-02-18 23:12 36 *****************
49 2017-02-18 23:13 37 ******************
... ..( 4 skipped). .. ******************
54 2017-02-18 23:18 37 ******************
55 2017-02-18 23:19 38 *******************
... ..( 3 skipped). .. *******************
59 2017-02-18 23:23 38 *******************
60 2017-02-18 23:24 39 ********************
61 2017-02-18 23:25 39 ********************
62 2017-02-18 23:26 39 ********************
63 2017-02-18 23:27 40 *********************
... ..( 8 skipped). .. *********************
72 2017-02-18 23:36 40 *********************
73 2017-02-18 23:37 39 ********************
74 2017-02-18 23:38 40 *********************
75 2017-02-18 23:39 40 *********************
76 2017-02-18 23:40 40 *********************
77 2017-02-18 23:41 ? -
78 2017-02-18 23:42 32 *************
79 2017-02-18 23:43 33 **************
80 2017-02-18 23:44 35 ****************
... ..( 2 skipped). .. ****************
83 2017-02-18 23:47 35 ****************
84 2017-02-18 23:48 36 *****************
85 2017-02-18 23:49 36 *****************
86 2017-02-18 23:50 37 ******************
87 2017-02-18 23:51 38 *******************
88 2017-02-18 23:52 38 *******************
89 2017-02-18 23:53 39 ********************
90 2017-02-18 23:54 39 ********************
91 2017-02-18 23:55 40 *********************
92 2017-02-18 23:56 40 *********************
93 2017-02-18 23:57 40 *********************
94 2017-02-18 23:58 41 **********************
... ..( 11 skipped). .. **********************
106 2017-02-19 00:10 41 **********************
107 2017-02-19 00:11 42 ***********************
... ..( 6 skipped). .. ***********************
114 2017-02-19 00:18 42 ***********************
115 2017-02-19 00:19 43 ************************
... ..( 3 skipped). .. ************************
119 2017-02-19 00:23 43 ************************
120 2017-02-19 00:24 44 *************************
121 2017-02-19 00:25 43 ************************
122 2017-02-19 00:26 43 ************************
123 2017-02-19 00:27 44 *************************
124 2017-02-19 00:28 43 ************************
125 2017-02-19 00:29 44 *************************
126 2017-02-19 00:30 44 *************************
127 2017-02-19 00:31 44 *************************
0 2017-02-19 00:32 43 ************************
1 2017-02-19 00:33 44 *************************
... ..( 2 skipped). .. *************************
4 2017-02-19 00:36 44 *************************
5 2017-02-19 00:37 ? -
6 2017-02-19 00:38 19 -
7 2017-02-19 00:39 20 *
8 2017-02-19 00:40 21 **
9 2017-02-19 00:41 22 ***
10 2017-02-19 00:42 22 ***
11 2017-02-19 00:43 23 ****
12 2017-02-19 00:44 24 *****
13 2017-02-19 00:45 ? -
14 2017-02-19 00:46 21 **
15 2017-02-19 00:47 21 **
16 2017-02-19 00:48 ? -
17 2017-02-19 00:49 31 ************
18 2017-02-19 00:50 32 *************
19 2017-02-19 00:51 34 ***************
20 2017-02-19 00:52 35 ****************
21 2017-02-19 00:53 35 ****************
22 2017-02-19 00:54 35 ****************
23 2017-02-19 00:55 36 *****************
... ..( 2 skipped). .. *****************
26 2017-02-19 00:58 36 *****************
27 2017-02-19 00:59 37 ******************
28 2017-02-19 01:00 37 ******************
29 2017-02-19 01:01 38 *******************
30 2017-02-19 01:02 38 *******************
31 2017-02-19 01:03 40 *********************
... ..( 3 skipped). .. *********************
35 2017-02-19 01:07 40 *********************
36 2017-02-19 01:08 41 **********************
... ..( 4 skipped). .. **********************
41 2017-02-19 01:13 41 **********************
SCT Error Recovery Control:
Read: 85 (8,5 seconds)
Write: 85 (8,5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1487 Vendor specific