/dev/nvme0n1
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: HS-SSD-E2000 2048G
Serial Number: --
Firmware Version: HBAF28FT
PCI Vendor/Subsystem ID: 0x126f
IEEE OUI Identifier: 0x000000
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,048,408,248,320 [2.04 TB]
Namespace 1 Utilization: 720,160,645,120 [720 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Sun Feb 12 06:18:36 2023 SAST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0b): S/H_per_NS Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 0 0
1 + 4.60W - - 1 1 1 1 0 0
2 + 3.80W - - 2 2 2 2 0 0
3 - 0.0450W - - 3 3 3 3 2000 2000
4 - 0.0040W - - 4 4 4 4 15000 15000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 35%
Data Units Read: 391,874,464 [200 TB]
Data Units Written: 905,079,923 [463 TB]
Host Read Commands: 9,525,064,404
Host Write Commands: 15,058,649,466
Controller Busy Time: 76,343
Power Cycles: 1,206
Power On Hours: 15,678
Unsafe Shutdowns: 190
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
/dev/nvme1n1
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KINGSTON SFYRD2000G
Serial Number: --
Firmware Version: EIFK31.6
PCI Vendor/Subsystem ID: 0x2646
IEEE OUI Identifier: 0x0026b7
Total NVM Capacity: 2,000,398,934,016 [2.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0026b7 ...
Local Time is: Sun Feb 12 06:18:36 2023 SAST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 89 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.80W - - 0 0 0 0 0 0
1 + 7.10W - - 1 1 1 1 0 0
2 + 5.20W - - 2 2 2 2 0 0
3 - 0.0620W - - 3 3 3 3 2500 7500
4 - 0.0620W - - 4 4 4 4 2500 7500
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 23 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 0%
Data Units Read: 1,530,391 [783 GB]
Data Units Written: 6,969,527 [3.56 TB]
Host Read Commands: 11,364,703
Host Write Commands: 48,655,947
Controller Busy Time: 235
Power Cycles: 646
Power On Hours: 340
Unsafe Shutdowns: 490
Media and Data Integrity Errors: 0
Error Information Log Entries: 27,672
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 2: 82 Celsius
Thermal Temp. 2 Transition Count: 1
Thermal Temp. 1 Total Time: 33
Thermal Temp. 2 Total Time: 4
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 27672 0 0xa018 0x4004 0x102c 0 0 -
1 27671 0 0x901b 0x4004 0x102c 0 0 -
2 27670 0 0x4011 0x4004 0x102c 0 0 -
3 27669 0 0x4010 0x4004 0x102c 0 0 -
4 27668 0 0x800e 0x4004 0x102c 0 0 -
5 27667 0 0x800d 0x4004 0x102c 0 0 -
6 27666 0 0x600f 0x4004 0x102c 0 0 -
7 27665 0 0x600e 0x4004 0x102c 0 0 -
8 27664 0 0x300b 0x4004 0x102c 0 0 -
9 27663 0 0x300a 0x4004 0x102c 0 0 -
10 27662 0 0x2012 0x4004 0x102c 0 0 -
11 27661 0 0x2011 0x4004 0x102c 0 0 -
12 27660 0 0x0013 0x4004 0x102c 0 0 -
13 27659 0 0x0012 0x4004 0x102c 0 0 -
14 27658 0 0xf010 0x4004 0x102c 0 0 -
15 27657 0 0xe013 0x4004 0x102c 0 0 -
... (47 entries not read)
/dev/nvme2n1
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Seagate FireCuda 510 SSD ZP1000GM30001
Serial Number: --
Firmware Version: STES1024
PCI Vendor/Subsystem ID: 0x1bb1
IEEE OUI Identifier: 0x0024cf
Total NVM Capacity: 1,000,204,886,016 [1.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0024cf ...
Local Time is: Sun Feb 12 06:18:36 2023 SAST
Firmware Updates (0x1e): 7 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0c): Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 90 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 10.73W - - 0 0 0 0 0 0
1 + 7.69W - - 1 1 1 1 0 0
2 + 6.18W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 42 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 14%
Data Units Read: 412,903,140 [211 TB]
Data Units Written: 296,135,775 [151 TB]
Host Read Commands: 4,974,893,242
Host Write Commands: 2,343,026,429
Controller Busy Time: 10,179
Power Cycles: 1,208
Power On Hours: 15,851
Unsafe Shutdowns: 194
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,812
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 1812 0 0x0018 0x4004 0x028 0 0 -
1 1811 0 0x0018 0x4004 0x028 0 0 -
2 1810 0 0x0001 0x4004 0x028 0 0 -
3 1809 0 0x0010 0x4004 0x028 0 0 -
4 1808 0 0x0008 0x4004 0x028 0 0 -
5 1807 0 0x0018 0x4004 0x028 0 0 -
6 1806 0 0x1008 0x4004 0x028 0 0 -
7 1805 0 0x001c 0x4004 0x028 0 0 -
8 1804 0 0x0008 0x4004 0x028 0 0 -
9 1803 0 0x000c 0x4004 0x028 0 0 -
10 1802 0 0x0004 0x4004 0x028 0 0 -
11 1801 0 0x0008 0x4004 0x028 0 0 -
12 1800 0 0x0010 0x4004 0x028 0 0 -
13 1799 0 0x5013 0x4004 0x028 0 0 -
14 1798 0 0x0014 0x4004 0x028 0 0 -
15 1797 0 0x000c 0x4004 0x028 0 0 -
... (47 entries not read)
/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 860 EVO 2TB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: RVT02B6Q
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Feb 12 06:18:36 2023 SAST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 160) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 095 095 000 - 22167
12 Power_Cycle_Count -O--CK 098 098 000 - 1601
177 Wear_Leveling_Count PO--C- 098 098 000 - 25
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 075 052 000 - 25
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 099 099 000 - 1
235 POR_Recovery_Count -O--C- 099 099 000 - 356
241 Total_LBAs_Written -O--CK 099 099 000 - 61926264236
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce-0xcf SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: 21/25 Celsius
Lifetime Min/Max Temperature: 11/48 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (3)
Index Estimated Time Temperature Celsius
4 2023-02-11 09:00 24 *****
5 2023-02-11 09:10 24 *****
6 2023-02-11 09:20 34 ***************
7 2023-02-11 09:30 28 *********
8 2023-02-11 09:40 25 ******
... ..( 16 skipped). .. ******
25 2023-02-11 12:30 25 ******
26 2023-02-11 12:40 26 *******
27 2023-02-11 12:50 25 ******
... ..( 8 skipped). .. ******
36 2023-02-11 14:20 25 ******
37 2023-02-11 14:30 ? -
38 2023-02-11 14:40 24 *****
39 2023-02-11 14:50 25 ******
40 2023-02-11 15:00 ? -
41 2023-02-11 15:10 24 *****
... ..( 8 skipped). .. *****
50 2023-02-11 16:40 24 *****
51 2023-02-11 16:50 25 ******
... ..( 4 skipped). .. ******
56 2023-02-11 17:40 25 ******
57 2023-02-11 17:50 ? -
58 2023-02-11 18:00 22 ***
59 2023-02-11 18:10 23 ****
... ..( 4 skipped). .. ****
64 2023-02-11 19:00 23 ****
65 2023-02-11 19:10 ? -
66 2023-02-11 19:20 23 ****
67 2023-02-11 19:30 23 ****
68 2023-02-11 19:40 23 ****
69 2023-02-11 19:50 29 **********
70 2023-02-11 20:00 30 ***********
... ..( 3 skipped). .. ***********
74 2023-02-11 20:40 30 ***********
75 2023-02-11 20:50 31 ************
... ..( 5 skipped). .. ************
81 2023-02-11 21:50 31 ************
82 2023-02-11 22:00 30 ***********
83 2023-02-11 22:10 25 ******
... ..( 4 skipped). .. ******
88 2023-02-11 23:00 25 ******
89 2023-02-11 23:10 24 *****
... ..( 10 skipped). .. *****
100 2023-02-12 01:00 24 *****
101 2023-02-12 01:10 ? -
102 2023-02-12 01:20 25 ******
103 2023-02-12 01:30 24 *****
104 2023-02-12 01:40 24 *****
105 2023-02-12 01:50 24 *****
106 2023-02-12 02:00 23 ****
107 2023-02-12 02:10 23 ****
108 2023-02-12 02:20 24 *****
109 2023-02-12 02:30 ? -
110 2023-02-12 02:40 24 *****
... ..( 6 skipped). .. *****
117 2023-02-12 03:50 24 *****
118 2023-02-12 04:00 33 **************
119 2023-02-12 04:10 35 ****************
120 2023-02-12 04:20 36 *****************
121 2023-02-12 04:30 28 *********
122 2023-02-12 04:40 24 *****
123 2023-02-12 04:50 23 ****
124 2023-02-12 05:00 ? -
125 2023-02-12 05:10 23 ****
126 2023-02-12 05:20 24 *****
... ..( 3 skipped). .. *****
2 2023-02-12 06:00 24 *****
3 2023-02-12 06:10 25 ******
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1601 --- Lifetime Power-On Resets
0x01 0x010 4 22167 --- Power-on Hours
0x01 0x018 6 61926264236 --- Logical Sectors Written
0x01 0x020 6 456657441 --- Number of Write Commands
0x01 0x028 6 24936087513 --- Logical Sectors Read
0x01 0x030 6 222683394 --- Number of Read Commands
0x01 0x038 6 3575000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 25 --- Current Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x028 1 11 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 7647 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 1 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 860 EVO 2TB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: RVT03B6Q
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Feb 12 06:18:36 2023 SAST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 160) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 096 096 000 - 15895
12 Power_Cycle_Count -O--CK 098 098 000 - 1206
177 Wear_Leveling_Count PO--C- 098 098 000 - 31
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 076 055 000 - 24
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 099 099 000 - 1
235 POR_Recovery_Count -O--C- 099 099 000 - 197
241 Total_LBAs_Written -O--CK 099 099 000 - 63648709938
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
256 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 24 Celsius
Power Cycle Min/Max Temperature: 21/25 Celsius
Lifetime Min/Max Temperature: -4/63 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (90)
Index Estimated Time Temperature Celsius
91 2023-02-11 09:00 24 *****
92 2023-02-11 09:10 24 *****
93 2023-02-11 09:20 33 **************
94 2023-02-11 09:30 27 ********
95 2023-02-11 09:40 25 ******
96 2023-02-11 09:50 25 ******
97 2023-02-11 10:00 25 ******
98 2023-02-11 10:10 24 *****
99 2023-02-11 10:20 24 *****
100 2023-02-11 10:30 25 ******
101 2023-02-11 10:40 25 ******
102 2023-02-11 10:50 24 *****
103 2023-02-11 11:00 25 ******
104 2023-02-11 11:10 25 ******
105 2023-02-11 11:20 24 *****
... ..( 4 skipped). .. *****
110 2023-02-11 12:10 24 *****
111 2023-02-11 12:20 25 ******
... ..( 2 skipped). .. ******
114 2023-02-11 12:50 25 ******
115 2023-02-11 13:00 24 *****
116 2023-02-11 13:10 24 *****
117 2023-02-11 13:20 25 ******
118 2023-02-11 13:30 24 *****
119 2023-02-11 13:40 24 *****
120 2023-02-11 13:50 25 ******
121 2023-02-11 14:00 24 *****
122 2023-02-11 14:10 25 ******
123 2023-02-11 14:20 24 *****
124 2023-02-11 14:30 ? -
125 2023-02-11 14:40 24 *****
126 2023-02-11 14:50 24 *****
127 2023-02-11 15:00 ? -
0 2023-02-11 15:10 24 *****
1 2023-02-11 15:20 24 *****
2 2023-02-11 15:30 23 ****
3 2023-02-11 15:40 24 *****
... ..( 7 skipped). .. *****
11 2023-02-11 17:00 24 *****
12 2023-02-11 17:10 25 ******
13 2023-02-11 17:20 24 *****
14 2023-02-11 17:30 24 *****
15 2023-02-11 17:40 24 *****
16 2023-02-11 17:50 ? -
17 2023-02-11 18:00 22 ***
18 2023-02-11 18:10 24 *****
19 2023-02-11 18:20 23 ****
... ..( 3 skipped). .. ****
23 2023-02-11 19:00 23 ****
24 2023-02-11 19:10 ? -
25 2023-02-11 19:20 23 ****
26 2023-02-11 19:30 23 ****
27 2023-02-11 19:40 23 ****
28 2023-02-11 19:50 29 **********
29 2023-02-11 20:00 30 ***********
30 2023-02-11 20:10 30 ***********
31 2023-02-11 20:20 31 ************
... ..( 8 skipped). .. ************
40 2023-02-11 21:50 31 ************
41 2023-02-11 22:00 29 **********
42 2023-02-11 22:10 25 ******
43 2023-02-11 22:20 24 *****
44 2023-02-11 22:30 25 ******
45 2023-02-11 22:40 24 *****
... ..( 2 skipped). .. *****
48 2023-02-11 23:10 24 *****
49 2023-02-11 23:20 23 ****
... ..( 2 skipped). .. ****
52 2023-02-11 23:50 23 ****
53 2023-02-12 00:00 24 *****
54 2023-02-12 00:10 23 ****
55 2023-02-12 00:20 23 ****
56 2023-02-12 00:30 23 ****
57 2023-02-12 00:40 24 *****
58 2023-02-12 00:50 23 ****
59 2023-02-12 01:00 24 *****
60 2023-02-12 01:10 ? -
61 2023-02-12 01:20 26 *******
62 2023-02-12 01:30 24 *****
63 2023-02-12 01:40 23 ****
... ..( 2 skipped). .. ****
66 2023-02-12 02:10 23 ****
67 2023-02-12 02:20 24 *****
68 2023-02-12 02:30 ? -
69 2023-02-12 02:40 24 *****
70 2023-02-12 02:50 24 *****
71 2023-02-12 03:00 23 ****
72 2023-02-12 03:10 23 ****
73 2023-02-12 03:20 24 *****
... ..( 2 skipped). .. *****
76 2023-02-12 03:50 24 *****
77 2023-02-12 04:00 31 ************
78 2023-02-12 04:10 33 **************
79 2023-02-12 04:20 34 ***************
80 2023-02-12 04:30 30 ***********
81 2023-02-12 04:40 24 *****
82 2023-02-12 04:50 23 ****
83 2023-02-12 05:00 ? -
84 2023-02-12 05:10 23 ****
85 2023-02-12 05:20 24 *****
... ..( 3 skipped). .. *****
89 2023-02-12 06:00 24 *****
90 2023-02-12 06:10 25 ******
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1206 --- Lifetime Power-On Resets
0x01 0x010 4 15895 --- Power-on Hours
0x01 0x018 6 63648709938 --- Logical Sectors Written
0x01 0x020 6 493552034 --- Number of Write Commands
0x01 0x028 6 26950621957 --- Logical Sectors Read
0x01 0x030 6 258905780 --- Number of Read Commands
0x01 0x038 6 1968000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 24 --- Current Temperature
0x05 0x020 1 63 --- Highest Temperature
0x05 0x028 1 -4 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4269 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 1 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdc
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.11-zen1-1-zen] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 860 EVO 4TB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: RVT01B6Q
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Feb 12 06:18:37 2023 SAST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 320) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 094 094 000 - 30281
12 Power_Cycle_Count -O--CK 099 099 000 - 320
177 Wear_Leveling_Count PO--C- 099 099 000 - 14
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 071 052 000 - 29
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 78
241 Total_LBAs_Written -O--CK 099 099 000 - 51738242811
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce-0xcf SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 27/42 Celsius
Lifetime Min/Max Temperature: 15/48 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (1)
Index Estimated Time Temperature Celsius
2 2023-02-11 09:00 ? -
... ..( 19 skipped). .. -
22 2023-02-11 12:20 ? -
23 2023-02-11 12:30 28 *********
24 2023-02-11 12:40 28 *********
25 2023-02-11 12:50 ? -
... ..( 27 skipped). .. -
53 2023-02-11 17:30 ? -
54 2023-02-11 17:40 28 *********
55 2023-02-11 17:50 28 *********
56 2023-02-11 18:00 ? -
57 2023-02-11 18:10 ? -
58 2023-02-11 18:20 28 *********
59 2023-02-11 18:30 ? -
60 2023-02-11 18:40 44 *************************
61 2023-02-11 18:50 46 ***************************
62 2023-02-11 19:00 47 ****************************
... ..( 4 skipped). .. ****************************
67 2023-02-11 19:50 47 ****************************
68 2023-02-11 20:00 48 *****************************
... ..( 3 skipped). .. *****************************
72 2023-02-11 20:40 48 *****************************
73 2023-02-11 20:50 47 ****************************
74 2023-02-11 21:00 48 *****************************
... ..( 2 skipped). .. *****************************
77 2023-02-11 21:30 48 *****************************
78 2023-02-11 21:40 ? -
79 2023-02-11 21:50 35 ****************
80 2023-02-11 22:00 40 *********************
81 2023-02-11 22:10 ? -
... ..( 4 skipped). .. -
86 2023-02-11 23:00 ? -
87 2023-02-11 23:10 28 *********
88 2023-02-11 23:20 ? -
... ..( 7 skipped). .. -
96 2023-02-12 00:40 ? -
97 2023-02-12 00:50 29 **********
98 2023-02-12 01:00 ? -
99 2023-02-12 01:10 28 *********
100 2023-02-12 01:20 ? -
101 2023-02-12 01:30 ? -
102 2023-02-12 01:40 28 *********
103 2023-02-12 01:50 ? -
104 2023-02-12 02:00 ? -
105 2023-02-12 02:10 27 ********
106 2023-02-12 02:20 ? -
107 2023-02-12 02:30 32 *************
108 2023-02-12 02:40 29 **********
109 2023-02-12 02:50 ? -
110 2023-02-12 03:00 ? -
111 2023-02-12 03:10 ? -
112 2023-02-12 03:20 28 *********
113 2023-02-12 03:30 ? -
114 2023-02-12 03:40 37 ******************
115 2023-02-12 03:50 40 *********************
116 2023-02-12 04:00 42 ***********************
117 2023-02-12 04:10 ? -
118 2023-02-12 04:20 ? -
119 2023-02-12 04:30 ? -
120 2023-02-12 04:40 27 ********
121 2023-02-12 04:50 ? -
... ..( 7 skipped). .. -
1 2023-02-12 06:10 ? -
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 320 --- Lifetime Power-On Resets
0x01 0x010 4 30281 --- Power-on Hours
0x01 0x018 6 51738242811 --- Logical Sectors Written
0x01 0x020 6 757932697 --- Number of Write Commands
0x01 0x028 6 119901595146 --- Logical Sectors Read
0x01 0x030 6 788824040 --- Number of Read Commands
0x01 0x038 6 671000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 29 --- Current Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x028 1 15 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 410 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC