Probe #d4bedb1907 of ASUSTek X550MJ
Log: smartctl
/dev/sda
=== START OF INFORMATION SECTION ===
Device Model: HGST HTS545050A7E680
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: GG2OAF10
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat May 28 18:12:35 2016 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 1 (minimum power consumption with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 45) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 112) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
2 Throughput_Performance P-S--- 100 100 040 - 0
3 Spin_Up_Time POS--- 247 247 033 - 0
4 Start_Stop_Count -O--C- 099 099 000 - 2597
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 100 100 040 - 0
9 Power_On_Hours -O--C- 094 094 000 - 2996
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 654
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 65536
192 Power-Off_Retract_Count -O--CK 100 100 000 - 10
193 Load_Cycle_Count -O--C- 099 099 000 - 19562
194 Temperature_Celsius -O---- 181 181 000 - 33 (Min/Max 18/42)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
223 Load_Retry_Count -O-R-- 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 32/37 Celsius
Lifetime Min/Max Temperature: 18/42 Celsius
Lifetime Average Temperature: 32 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (88)
Index Estimated Time Temperature Celsius
89 2016-05-28 16:05 37 ******************
... ..( 2 skipped). .. ******************
92 2016-05-28 16:08 37 ******************
93 2016-05-28 16:09 36 *****************
94 2016-05-28 16:10 36 *****************
95 2016-05-28 16:11 35 ****************
... ..( 5 skipped). .. ****************
101 2016-05-28 16:17 35 ****************
102 2016-05-28 16:18 36 *****************
... ..( 2 skipped). .. *****************
105 2016-05-28 16:21 36 *****************
106 2016-05-28 16:22 35 ****************
107 2016-05-28 16:23 36 *****************
108 2016-05-28 16:24 36 *****************
109 2016-05-28 16:25 35 ****************
... ..( 5 skipped). .. ****************
115 2016-05-28 16:31 35 ****************
116 2016-05-28 16:32 36 *****************
117 2016-05-28 16:33 36 *****************
118 2016-05-28 16:34 36 *****************
119 2016-05-28 16:35 35 ****************
120 2016-05-28 16:36 35 ****************
121 2016-05-28 16:37 36 *****************
122 2016-05-28 16:38 36 *****************
123 2016-05-28 16:39 36 *****************
124 2016-05-28 16:40 37 ******************
125 2016-05-28 16:41 37 ******************
126 2016-05-28 16:42 36 *****************
... ..( 4 skipped). .. *****************
3 2016-05-28 16:47 36 *****************
4 2016-05-28 16:48 35 ****************
5 2016-05-28 16:49 35 ****************
6 2016-05-28 16:50 36 *****************
... ..( 2 skipped). .. *****************
9 2016-05-28 16:53 36 *****************
10 2016-05-28 16:54 37 ******************
11 2016-05-28 16:55 37 ******************
12 2016-05-28 16:56 36 *****************
13 2016-05-28 16:57 36 *****************
14 2016-05-28 16:58 35 ****************
15 2016-05-28 16:59 35 ****************
16 2016-05-28 17:00 35 ****************
17 2016-05-28 17:01 34 ***************
... ..( 4 skipped). .. ***************
22 2016-05-28 17:06 34 ***************
23 2016-05-28 17:07 33 **************
... ..( 8 skipped). .. **************
32 2016-05-28 17:16 33 **************
33 2016-05-28 17:17 32 *************
34 2016-05-28 17:18 33 **************
... ..( 3 skipped). .. **************
38 2016-05-28 17:22 33 **************
39 2016-05-28 17:23 32 *************
40 2016-05-28 17:24 33 **************
41 2016-05-28 17:25 32 *************
... ..( 2 skipped). .. *************
44 2016-05-28 17:28 32 *************
45 2016-05-28 17:29 33 **************
46 2016-05-28 17:30 33 **************
47 2016-05-28 17:31 32 *************
... ..( 27 skipped). .. *************
75 2016-05-28 17:59 32 *************
76 2016-05-28 18:00 33 **************
... ..( 11 skipped). .. **************
88 2016-05-28 18:12 33 **************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS