Probe #d4d069aa0c of Acer Extensa 215-52

Log: smartctl

/dev/nvme0n1 smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.2.13-zen-1-zen] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: KINGSTON RBUSNS8154P3256GJ1 Serial Number: -- Firmware Version: E8FK12.3 PCI Vendor/Subsystem ID: 0x2646 IEEE OUI Identifier: 0x0026b7 Total NVM Capacity: 256,060,514,304 [256 GB] Unallocated NVM Capacity: 0 Controller ID: 0 NVMe Version: 1.2 Number of Namespaces: 1 Namespace 1 Size/Capacity: 256,060,514,304 [256 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 0026b7 ... Local Time is: Thu May 4 19:51:18 2023 BST Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0007): Security Format Frmw_DL Optional NVM Commands (0x001e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Log Page Attributes (0x04): Ext_Get_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 84 Celsius Critical Comp. Temp. Threshold: 88 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 7.90W 0.0790W - 0 0 0 0 600 600 1 + 7.90W 0.0790W - 0 0 0 0 600 600 2 + 7.90W 0.0790W - 0 0 0 0 600 600 3 - 0.1000W 0.0790W - 3 3 3 3 1000 1000 4 - 0.0050W 0.0790W - 4 4 4 4 400000 90000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 25 Celsius Available Spare: 100% Available Spare Threshold: 100% Percentage Used: 2% Data Units Read: 28,998,432 [14.8 TB] Data Units Written: 12,167,735 [6.22 TB] Host Read Commands: 313,415,510 Host Write Commands: 103,369,319 Controller Busy Time: 682 Power Cycles: 1,149 Power On Hours: 237 Unsafe Shutdowns: 340 Media and Data Integrity Errors: 0 Error Information Log Entries: 2,365 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 2: 25 Celsius Error Information (NVMe Log 0x01, 16 of 16 entries) Num ErrCount SQId CmdId Status PELoc LBA NSID VS 0 2365 0 0x0000 0x0005 - 6 0 - 1 2364 0 0x0015 0x0005 - 12 0 - 2 2363 0 0x000d 0x0005 - 4009754624 1 - 3 2362 0 0x000d 0x0005 - 4009754624 1 - 4 2361 0 0x000d 0x0005 - 4009754624 1 - 5 2360 0 0x000d 0x0005 - 4009754624 1 - 6 2359 0 0x000d 0x0005 - 4009754624 1 - 7 2357 0 0x000d 0x0005 - 12 0 - 8 2356 0 0x0017 0x0004 - 4009754624 1 - 9 2355 0 0x0001 0x0005 - 6 - - 10 2354 0 0x000d 0x0005 - 4009754624 1 - 11 2353 0 0x001c 0x0005 - 6 0 - 12 2352 0 0x0009 0x0005 - 12 0 - 13 2351 0 0x000d 0x0005 - 4009754624 1 - 14 2342 0 0x0001 0x0005 - 6 - - 15 2334 0 0x000d 0x0005 - 4009754624 1 -


Hardware for Linux and BSD

GitHub