Probe #db2f72084a of Intel Calistoga & ICH7M Ch...
Log: smartctl
/dev/sda
smartctl 7.2 2020-12-30 r5155 [i686-linux-5.10.0-20-686] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD2500BEVT-00ZCT0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 11.01A11
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Tue Feb 7 20:43:50 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7500) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 90) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 187 185 021 - 1650
4 Start_Stop_Count -O--CK 095 095 000 - 5495
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 089 089 000 - 8360
10 Spin_Retry_Count PO--CK 100 098 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 096 096 000 - 4294
192 Power-Off_Retract_Count -O--CK 199 199 000 - 761
193 Load_Cycle_Count -O--CK 120 120 000 - 241831
194 Temperature_Celsius -O---K 098 079 000 - 49
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 3
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 49 Celsius
Power Cycle Min/Max Temperature: 32/49 Celsius
Lifetime Min/Max Temperature: 18/69 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 1/85 Celsius
Temperature History Size (Index): 128 (4)
Index Estimated Time Temperature Celsius
5 2023-02-07 18:36 40 *********************
... ..( 6 skipped). .. *********************
12 2023-02-07 18:43 40 *********************
13 2023-02-07 18:44 41 **********************
... ..( 18 skipped). .. **********************
32 2023-02-07 19:03 41 **********************
33 2023-02-07 19:04 42 ***********************
... ..( 15 skipped). .. ***********************
49 2023-02-07 19:20 42 ***********************
50 2023-02-07 19:21 ? -
51 2023-02-07 19:22 17 -
52 2023-02-07 19:23 18 -
53 2023-02-07 19:24 19 -
54 2023-02-07 19:25 21 **
55 2023-02-07 19:26 22 ***
56 2023-02-07 19:27 23 ****
57 2023-02-07 19:28 24 *****
58 2023-02-07 19:29 25 ******
59 2023-02-07 19:30 26 *******
60 2023-02-07 19:31 26 *******
61 2023-02-07 19:32 27 ********
62 2023-02-07 19:33 28 *********
63 2023-02-07 19:34 29 **********
64 2023-02-07 19:35 ? -
65 2023-02-07 19:36 31 ************
66 2023-02-07 19:37 32 *************
67 2023-02-07 19:38 32 *************
68 2023-02-07 19:39 34 ***************
69 2023-02-07 19:40 34 ***************
70 2023-02-07 19:41 35 ****************
71 2023-02-07 19:42 37 ******************
72 2023-02-07 19:43 37 ******************
73 2023-02-07 19:44 39 ********************
74 2023-02-07 19:45 39 ********************
75 2023-02-07 19:46 41 **********************
76 2023-02-07 19:47 41 **********************
77 2023-02-07 19:48 42 ***********************
78 2023-02-07 19:49 43 ************************
79 2023-02-07 19:50 43 ************************
80 2023-02-07 19:51 44 *************************
81 2023-02-07 19:52 44 *************************
82 2023-02-07 19:53 44 *************************
83 2023-02-07 19:54 45 **************************
84 2023-02-07 19:55 45 **************************
85 2023-02-07 19:56 45 **************************
86 2023-02-07 19:57 ? -
87 2023-02-07 19:58 36 *****************
88 2023-02-07 19:59 ? -
89 2023-02-07 20:00 37 ******************
90 2023-02-07 20:01 ? -
91 2023-02-07 20:02 37 ******************
92 2023-02-07 20:03 ? -
93 2023-02-07 20:04 32 *************
94 2023-02-07 20:05 ? -
95 2023-02-07 20:06 32 *************
96 2023-02-07 20:07 33 **************
97 2023-02-07 20:08 34 ***************
98 2023-02-07 20:09 35 ****************
99 2023-02-07 20:10 36 *****************
100 2023-02-07 20:11 37 ******************
101 2023-02-07 20:12 39 ********************
102 2023-02-07 20:13 39 ********************
103 2023-02-07 20:14 40 *********************
104 2023-02-07 20:15 41 **********************
105 2023-02-07 20:16 42 ***********************
106 2023-02-07 20:17 42 ***********************
107 2023-02-07 20:18 43 ************************
108 2023-02-07 20:19 44 *************************
109 2023-02-07 20:20 44 *************************
110 2023-02-07 20:21 44 *************************
111 2023-02-07 20:22 45 **************************
112 2023-02-07 20:23 45 **************************
113 2023-02-07 20:24 45 **************************
114 2023-02-07 20:25 46 ***************************
115 2023-02-07 20:26 46 ***************************
116 2023-02-07 20:27 46 ***************************
117 2023-02-07 20:28 47 ****************************
118 2023-02-07 20:29 47 ****************************
119 2023-02-07 20:30 47 ****************************
120 2023-02-07 20:31 48 *****************************
... ..( 2 skipped). .. *****************************
123 2023-02-07 20:34 48 *****************************
124 2023-02-07 20:35 49 ******************************
... ..( 7 skipped). .. ******************************
4 2023-02-07 20:43 49 ******************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x8000 4 2282 Vendor specific