Probe #dcb2ce2ebd of ASUSTek H170M-PLUS Desktop Computer
Log: smartctl
/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: KINGSTON SVP200S37A120G
Serial Number: --
LU WWN Device Id: 5 0026b7 ...
Firmware Version: 502ABBF0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Mar 22 19:04:48 2018 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Disabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0021) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 050 - 0/4654978
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 2340h+55m+40.210s
12 Power_Cycle_Count -O--CK 100 100 000 - 903
171 Program_Fail_Count -O--CK 000 000 000 - 0
172 Erase_Fail_Count -O--CK 000 000 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 223
177 Wear_Range_Delta ------ 000 000 000 - 1
181 Program_Fail_Count -O--CK 000 000 000 - 0
182 Erase_Fail_Count -O--CK 000 000 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 Airflow_Temperature_Cel ------ 020 074 000 - 20 (Min/Max 15/74)
194 Temperature_Celsius -O---K 020 074 000 - 20 (Min/Max 15/74)
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/4654978
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/4654978
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/4654978
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 100 100 010 - 0
233 SandForce_Internal ------ 000 000 000 - 1788
234 SandForce_Internal -O--CK 000 000 000 - 2230
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 2230
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 2180
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 20 Celsius
Power Cycle Min/Max Temperature: 20/21 Celsius
Lifetime Min/Max Temperature: 15/74 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 10 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: -28/99 Celsius
Min/Max Temperature Limit: 37/ 8 Celsius
Temperature History Size (Index): 60672 (54)
Invalid Temperature History Size or Index
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS