Probe #de602b4dc6 of HP Laptop 14s-dy5xxx
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.8-200.fc39.x86_64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PSEJN512GA87EC0
Serial Number: --
Firmware Version: HPE36P01
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Dec 27 09:17:29 2023 IST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 3.00W - - 1 1 1 1 0 0
2 + 1.50W - - 2 2 2 2 0 0
3 - 0.1000W - - 3 3 3 3 5000 10000
4 - 0.0025W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 34 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 2%
Data Units Read: 28,884,632 [14.7 TB]
Data Units Written: 23,185,968 [11.8 TB]
Host Read Commands: 152,090,972
Host Write Commands: 198,914,248
Controller Busy Time: 675
Power Cycles: 843
Power On Hours: 181
Unsafe Shutdowns: 84
Media and Data Integrity Errors: 0
Error Information Log Entries: 2,175
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 39 Celsius
Temperature Sensor 2: 34 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 2175 0 0x001c 0xc004 0x028 0 0 - Invalid Field in Command
1 2174 0 0x0010 0xc004 0x028 0 0 - Invalid Field in Command
2 2173 0 0x0004 0xc004 0x028 0 0 - Invalid Field in Command
3 2172 0 0x8000 0xc004 0x028 0 0 - Invalid Field in Command
4 2171 0 0x100c 0xc005 0x004 0 1 - Invalid Field in Command
5 2170 0 0x8010 0xc005 0x004 0 1 - Invalid Field in Command
6 2169 0 0x0018 0xc004 0x028 0 0 - Invalid Field in Command
7 2168 0 0xf008 0xc005 0x004 0 1 - Invalid Field in Command
8 2167 0 0x201b 0xc005 0x004 0 1 - Invalid Field in Command
9 2166 0 0x0018 0xc004 0x028 0 0 - Invalid Field in Command
10 2165 0 0x1004 0xc005 0x004 0 1 - Invalid Field in Command
11 2164 0 0x1013 0xc005 0x004 0 1 - Invalid Field in Command
12 2163 0 0x000c 0xc004 0x028 0 0 - Invalid Field in Command
13 2162 0 0x800b 0xc005 0x004 0 1 - Invalid Field in Command
14 2161 0 0x1019 0xc005 0x004 0 1 - Invalid Field in Command
15 2160 0 0x000c 0xc004 0x028 0 0 - Invalid Field in Command
... (47 entries not read)
Read Self-test Log failed: Invalid Field in Command (0x6002)