/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue
Device Model: WDC WD5000AAKX-08U6AA0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 19.01H19
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Mar 30 18:08:38 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 8700) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 88) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 298
3 Spin_Up_Time POS--K 141 139 021 - 3941
4 Start_Stop_Count -O--CK 097 097 000 - 3151
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 073 073 000 - 20353
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2947
192 Power-Off_Retract_Count -O--CK 200 200 000 - 244
193 Load_Cycle_Count -O--CK 200 200 000 - 2906
194 Temperature_Celsius -O---K 108 099 000 - 35
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 2406
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 313 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 313 [0] occurred at disk power-on lifetime: 19920 hours (830 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 02 44 82 19 e0 00
Error: UNC at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 01 00 00 00 02 44 82 00 e0 00 05:43:44.080 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 81 00 e0 00 05:43:44.079 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 80 00 e0 00 05:43:44.078 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 7f 00 e0 00 05:43:44.077 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 7e 00 e0 00 05:43:44.075 READ VERIFY SECTOR(S) EXT
Error 312 [23] occurred at disk power-on lifetime: 19832 hours (826 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 01 00 00 00 02 44 82 19 e0 00
Error: UNC at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 01 00 00 00 02 44 82 00 e0 00 01:38:37.048 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 81 00 e0 00 01:38:37.048 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 80 00 e0 00 01:38:37.047 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 7f 00 e0 00 01:38:37.046 READ VERIFY SECTOR(S) EXT
42 00 00 01 00 00 00 02 44 7e 00 e0 00 01:38:37.044 READ VERIFY SECTOR(S) EXT
Error 311 [22] occurred at disk power-on lifetime: 19802 hours (825 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 02 44 82 19 40 00
Error: UNC 1 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 02 44 82 19 40 00 02:10:42.456 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 18 40 00 02:10:42.456 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 17 40 00 02:10:42.455 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 16 40 00 02:10:42.455 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 15 40 00 02:10:42.455 READ DMA EXT
Error 310 [21] occurred at disk power-on lifetime: 19802 hours (825 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 f8 00 00 02 44 82 19 40 00
Error: UNC 248 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 f8 00 00 02 44 81 f0 40 00 02:10:40.488 READ DMA EXT
25 00 00 00 f8 00 00 02 44 80 f8 40 00 02:10:40.487 READ DMA EXT
25 00 00 00 f8 00 00 02 44 80 00 40 00 02:10:40.487 READ DMA EXT
25 00 00 00 40 00 00 02 44 7f c0 40 00 02:10:40.486 READ DMA EXT
25 00 00 00 f8 00 00 02 44 7e c8 40 00 02:10:40.485 READ DMA EXT
Error 309 [20] occurred at disk power-on lifetime: 19802 hours (825 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 02 44 82 19 40 00
Error: UNC 1 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 02 44 82 19 40 00 02:05:59.005 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 18 40 00 02:05:59.005 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 17 40 00 02:05:59.004 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 16 40 00 02:05:59.004 READ DMA EXT
25 00 00 00 01 00 00 02 44 82 15 40 00 02:05:59.004 READ DMA EXT
Error 308 [19] occurred at disk power-on lifetime: 19802 hours (825 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 f8 00 00 02 44 82 19 40 00
Error: UNC 248 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 f8 00 00 02 44 81 f0 40 00 02:05:56.954 READ DMA EXT
25 00 00 00 f8 00 00 02 44 80 f8 40 00 02:05:56.953 READ DMA EXT
25 00 00 00 f8 00 00 02 44 80 00 40 00 02:05:56.952 READ DMA EXT
25 00 00 00 40 00 00 02 44 7f c0 40 00 02:05:56.952 READ DMA EXT
25 00 00 00 f8 00 00 02 44 7e c8 40 00 02:05:56.951 READ DMA EXT
Error 307 [18] occurred at disk power-on lifetime: 19800 hours (825 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 40 00 00 02 44 82 19 40 00
Error: UNC 64 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 40 00 00 02 44 82 00 40 00 00:40:26.422 READ DMA EXT
35 00 00 00 08 00 00 00 65 54 80 40 00 00:40:26.422 WRITE DMA EXT
25 00 00 00 40 00 00 11 d3 b9 da 40 00 00:40:26.422 READ DMA EXT
25 00 00 00 f8 00 00 11 d3 b8 e2 40 00 00:40:26.420 READ DMA EXT
25 00 00 00 f8 00 00 11 d3 b7 ea 40 00 00:40:26.419 READ DMA EXT
Error 306 [17] occurred at disk power-on lifetime: 19800 hours (825 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 40 00 00 02 44 82 19 40 00
Error: UNC 64 sectors at LBA = 0x02448219 = 38044185
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 40 00 00 02 44 82 00 40 00 00:39:23.923 READ DMA EXT
25 00 00 00 40 00 00 11 04 39 da 40 00 00:39:23.923 READ DMA EXT
25 00 00 00 f8 00 00 11 04 38 e2 40 00 00:39:23.922 READ DMA EXT
25 00 00 00 f8 00 00 11 04 37 ea 40 00 00:39:23.921 READ DMA EXT
25 00 00 00 f8 00 00 11 04 36 f2 40 00 00:39:23.919 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 34/35 Celsius
Lifetime Min/Max Temperature: 0/44 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (174)
Index Estimated Time Temperature Celsius
175 2020-03-30 10:11 35 ****************
... ..( 20 skipped). .. ****************
196 2020-03-30 10:32 35 ****************
197 2020-03-30 10:33 ? -
198 2020-03-30 10:34 23 ****
199 2020-03-30 10:35 24 *****
200 2020-03-30 10:36 25 ******
201 2020-03-30 10:37 26 *******
202 2020-03-30 10:38 26 *******
203 2020-03-30 10:39 27 ********
204 2020-03-30 10:40 27 ********
205 2020-03-30 10:41 29 **********
206 2020-03-30 10:42 29 **********
207 2020-03-30 10:43 29 **********
208 2020-03-30 10:44 30 ***********
209 2020-03-30 10:45 30 ***********
210 2020-03-30 10:46 31 ************
211 2020-03-30 10:47 32 *************
... ..( 6 skipped). .. *************
218 2020-03-30 10:54 32 *************
219 2020-03-30 10:55 33 **************
... ..( 5 skipped). .. **************
225 2020-03-30 11:01 33 **************
226 2020-03-30 11:02 34 ***************
227 2020-03-30 11:03 34 ***************
228 2020-03-30 11:04 33 **************
229 2020-03-30 11:05 34 ***************
... ..( 17 skipped). .. ***************
247 2020-03-30 11:23 34 ***************
248 2020-03-30 11:24 35 ****************
249 2020-03-30 11:25 34 ***************
250 2020-03-30 11:26 35 ****************
251 2020-03-30 11:27 35 ****************
252 2020-03-30 11:28 35 ****************
253 2020-03-30 11:29 34 ***************
254 2020-03-30 11:30 34 ***************
255 2020-03-30 11:31 34 ***************
256 2020-03-30 11:32 35 ****************
257 2020-03-30 11:33 34 ***************
258 2020-03-30 11:34 35 ****************
259 2020-03-30 11:35 35 ****************
260 2020-03-30 11:36 34 ***************
261 2020-03-30 11:37 35 ****************
262 2020-03-30 11:38 34 ***************
... ..( 13 skipped). .. ***************
276 2020-03-30 11:52 34 ***************
277 2020-03-30 11:53 35 ****************
... ..( 16 skipped). .. ****************
294 2020-03-30 12:10 35 ****************
295 2020-03-30 12:11 34 ***************
296 2020-03-30 12:12 ? -
297 2020-03-30 12:13 35 ****************
... ..( 29 skipped). .. ****************
327 2020-03-30 12:43 35 ****************
328 2020-03-30 12:44 34 ***************
... ..( 2 skipped). .. ***************
331 2020-03-30 12:47 34 ***************
332 2020-03-30 12:48 33 **************
... ..( 48 skipped). .. **************
381 2020-03-30 13:37 33 **************
382 2020-03-30 13:38 34 ***************
383 2020-03-30 13:39 33 **************
384 2020-03-30 13:40 33 **************
385 2020-03-30 13:41 33 **************
386 2020-03-30 13:42 34 ***************
387 2020-03-30 13:43 33 **************
388 2020-03-30 13:44 33 **************
389 2020-03-30 13:45 34 ***************
390 2020-03-30 13:46 33 **************
391 2020-03-30 13:47 34 ***************
... ..( 15 skipped). .. ***************
407 2020-03-30 14:03 34 ***************
408 2020-03-30 14:04 35 ****************
... ..( 7 skipped). .. ****************
416 2020-03-30 14:12 35 ****************
417 2020-03-30 14:13 34 ***************
418 2020-03-30 14:14 35 ****************
419 2020-03-30 14:15 35 ****************
420 2020-03-30 14:16 34 ***************
... ..( 11 skipped). .. ***************
432 2020-03-30 14:28 34 ***************
433 2020-03-30 14:29 33 **************
434 2020-03-30 14:30 33 **************
435 2020-03-30 14:31 34 ***************
436 2020-03-30 14:32 34 ***************
437 2020-03-30 14:33 33 **************
... ..( 4 skipped). .. **************
442 2020-03-30 14:38 33 **************
443 2020-03-30 14:39 34 ***************
444 2020-03-30 14:40 33 **************
445 2020-03-30 14:41 33 **************
446 2020-03-30 14:42 33 **************
447 2020-03-30 14:43 34 ***************
448 2020-03-30 14:44 33 **************
449 2020-03-30 14:45 33 **************
450 2020-03-30 14:46 34 ***************
... ..( 18 skipped). .. ***************
469 2020-03-30 15:05 34 ***************
470 2020-03-30 15:06 ? -
471 2020-03-30 15:07 33 **************
... ..( 4 skipped). .. **************
476 2020-03-30 15:12 33 **************
477 2020-03-30 15:13 34 ***************
... ..( 4 skipped). .. ***************
4 2020-03-30 15:18 34 ***************
5 2020-03-30 15:19 35 ****************
6 2020-03-30 15:20 34 ***************
7 2020-03-30 15:21 35 ****************
8 2020-03-30 15:22 34 ***************
9 2020-03-30 15:23 35 ****************
... ..( 9 skipped). .. ****************
19 2020-03-30 15:33 35 ****************
20 2020-03-30 15:34 34 ***************
21 2020-03-30 15:35 35 ****************
... ..( 12 skipped). .. ****************
34 2020-03-30 15:48 35 ****************
35 2020-03-30 15:49 ? -
36 2020-03-30 15:50 26 *******
37 2020-03-30 15:51 26 *******
38 2020-03-30 15:52 27 ********
39 2020-03-30 15:53 28 *********
40 2020-03-30 15:54 29 **********
41 2020-03-30 15:55 30 ***********
42 2020-03-30 15:56 32 *************
43 2020-03-30 15:57 32 *************
44 2020-03-30 15:58 32 *************
45 2020-03-30 15:59 33 **************
46 2020-03-30 16:00 33 **************
47 2020-03-30 16:01 34 ***************
48 2020-03-30 16:02 35 ****************
49 2020-03-30 16:03 35 ****************
50 2020-03-30 16:04 35 ****************
51 2020-03-30 16:05 ? -
52 2020-03-30 16:06 34 ***************
... ..( 2 skipped). .. ***************
55 2020-03-30 16:09 34 ***************
56 2020-03-30 16:10 35 ****************
57 2020-03-30 16:11 34 ***************
58 2020-03-30 16:12 35 ****************
59 2020-03-30 16:13 35 ****************
60 2020-03-30 16:14 34 ***************
61 2020-03-30 16:15 35 ****************
62 2020-03-30 16:16 35 ****************
63 2020-03-30 16:17 35 ****************
64 2020-03-30 16:18 34 ***************
65 2020-03-30 16:19 35 ****************
... ..( 5 skipped). .. ****************
71 2020-03-30 16:25 35 ****************
72 2020-03-30 16:26 34 ***************
73 2020-03-30 16:27 35 ****************
... ..(100 skipped). .. ****************
174 2020-03-30 18:08 35 ****************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 4247 Vendor specific