Probe #f4be121773 of Lenovo Yoga 720-13IKB 80X6
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.15-amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLW128HEGR-000L2
Serial Number: --
Firmware Version: 4L1QCXB7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 2
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Utilization: 23,575,212,032 [23.5 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Mon Sep 2 08:58:53 2024 EDT
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Warning Comp. Temp. Threshold: 69 Celsius
Critical Comp. Temp. Threshold: 72 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.60W - - 0 0 0 0 0 0
1 + 6.00W - - 1 1 1 1 0 0
2 + 5.10W - - 2 2 2 2 0 0
3 - 0.0400W - - 3 3 3 3 210 1500
4 - 0.0050W - - 4 4 4 4 2200 6000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 33 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 7%
Data Units Read: 31,129,274 [15.9 TB]
Data Units Written: 16,295,409 [8.34 TB]
Host Read Commands: 530,913,585
Host Write Commands: 233,158,086
Controller Busy Time: 1,497
Power Cycles: 1,118
Power On Hours: 4,886
Unsafe Shutdowns: 125
Media and Data Integrity Errors: 0
Error Information Log Entries: 687
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 33 Celsius
Temperature Sensor 2: 48 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 687 0 0x0010 0x4004 - 0 0 - Invalid Field in Command
1 686 0 0x3012 0x4004 - 0 0 - Invalid Field in Command
2 685 0 0x0018 0x4004 - 0 0 - Invalid Field in Command
3 684 0 0x0008 0x4004 - 0 0 - Invalid Field in Command
4 683 0 0x0008 0x4004 - 0 0 - Invalid Field in Command
5 682 0 0x0018 0x4004 - 0 0 - Invalid Field in Command
6 681 0 0x0010 0x4004 - 0 0 - Invalid Field in Command
7 680 0 0x0018 0x4004 - 0 0 - Invalid Field in Command
8 679 0 0x001c 0x4004 - 0 0 - Invalid Field in Command
9 678 0 0x1004 0x4004 - 0 0 - Invalid Field in Command
10 677 0 0x0004 0x4004 - 0 0 - Invalid Field in Command
11 676 0 0x3006 0x4004 - 0 0 - Invalid Field in Command
12 675 0 0x0004 0x4004 - 0 0 - Invalid Field in Command
13 674 0 0x000c 0x4004 - 0 0 - Invalid Field in Command
14 673 0 0x0000 0x4004 - 0 0 - Invalid Field in Command
15 672 0 0x0010 0x4004 - 0 0 - Invalid Field in Command
... (48 entries not read)
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged